west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "Diagnostic techniques" 17 results
  • Clinical Study of Influent Factors on Normal Intraabdominal Pressure

    【Abstract】Objective To investigate the influent factors on normal intraabdominal pressure (IAP) and establish the IAP regressive equation. Methods The IAPs of 106 hospitalized patients were determined through monitoring the bladder pressures. The relationship between IAP and 14 factors including age, gender, height, weight, body mass index (BMI), previous and recent abdominal surgical history, reasons for admission,complications and their quantities were analyzed,respectively.Results The mean IAP of the hospitalized patients was 5.5 mm Hg with a range from 0.4 mm Hg to 12.8 mm Hg. The difference among IAPs of different grades of BMIs had statistical significance (F=5.550,P<0.01). The male IAPs were 2.0 mm Hg higher than the female IAPs,which had statistical significance (t=3.122,P<0.01). The other 12 factors had no significant effects on IAP (Pgt;0.05). Conclusion Normal IAP is possibly influenced by gender and BMI,and it is individually different.

    Release date:2016-08-28 04:44 Export PDF Favorites Scan
  • Optical coherence tomography: a new era of ocular-fundus imageologic

    Optical coherence tomography (OCT) has developed from time-doma in into Fourier-domain OCT (FD-OCT) which indicates clearer details and higher resolution of images. FD-OCT can indicate the structure and pathological changes of each retinal layer, and reveal the retinal external limiting membranes and changes of inner- and outer-segment of visual cells by 3D solid reconstruction. FD-OCT not only provide detailed information of the images for the clinical diagnosis, but also help us investigting the characteristics and pthological mechanisms of ocular fundus diseases, which lead us to a new era of technology of observation on ocualr fundus diseases. In the application, we should pay attention to the significance of different colors of OCT images, and focus on the cohenrence of the position in the image acquistion during the follow-up period. Dynamic observation on the lesions by FD-OCT and aggregated anaylsis of resutls of several imageological examination would be the development direction of imageological examination of ocular fundus diseases.

    Release date:2016-09-02 05:42 Export PDF Favorites Scan
  • Investigation of the association between the macular volume and thick ness by optical coherence tomography, with refraction state and axial length in children

    Purpose To investigate the association between the macular volume and thickness, as assessed by optical coherence tomography (OCT), with refraction state and axial length (AL) in children. Methods A total of 100 normal children whose right eyes were randomly selected were divided into five groups due to their refraction, comprising hyperopia, emmetropia, low myopia, moderate myopia, high myopia. The AL of the eyes was measured by IOL mas ter measuring machine. Then the macular volume and thickness were measured by OCT. Results Children with high myopia have smaller macular volume and thinner parafoveal retinal thickness (especially out-ring macular). The minimum thickness and average thickness of the fovea were not significantly different among the five groups. The macular volume ,total average macular thickness and quadrant-specific macular thickness(except the nasal inner quadrants) were positively associated with refraction and negatively associated with AL, while t here were no correlation between minimum foveal thickness, the average foveal th ickness and refraction or AL. Conclusions In Chinese children, increasing axial length was associated with reduced macular volume and thickness (except the foveal region and the nasal inner quadrant). (Chin J Ocul Fundus Dis,2008,24:114-117)

    Release date:2016-09-02 05:46 Export PDF Favorites Scan
  • Appropriate understanding and applying the basic diagnostic and examining technques of ocular fundus diseases

    In recent years, more and more new diagnostic and examining techniques are popularized, which improves the level of ocular fundus disease diagnosis and treatment. Because of the uneven distribution of diagnostic and therapeutic instruments resources, low level of application techniques, and different professional level of the doctors, the improvement and development of the application of the equipments and level of the diagnosis and treatment were inhibited. Appropriate understanding and applying basic diagnostic techniques of ocular fundus disease and comprehensive promoting the professionalsprime; levels are an urgent problem needs to be solved.

    Release date:2016-09-02 05:48 Export PDF Favorites Scan
  • Ultrasonography on eyes with silicon oil tamponade

    Objective To investigate the characteristics of ultrasonogram of eyes with silicon oil tamponade. Methods Forty-seven patients (47 eyes) who had undergone the operation of silicon-oil removing were examined by A-(to determine the length of ocular axis) and B-scan before and after the operation respectively. The length of ocular axis and cubage of vitreous chamber were detected and the characteristics of the ultrasonograms were observed according to the default parameters of ultrasonograph. Results The results of A-scan showed that the preoperative axial length was 1.465 times of the postoperative one in the eyes without lens, and 1.284 times in eyes with lens; after modified the parameter according to the acoustic velocity, the preoperative axial length was (0.78±0.34) mm longer than the postoperative one in the eyes without lens, and (0.56±0.32) mm in eyes with lens. The results of A-scan showed that the cubage of vitreous chamber enlarged obviously in eyes with silicon oil tamponade, and the acoustic features included complete filling and partial filling according to the amount of silicon oil. Several arc echoes at the posterior segment of eye were detected in the silicon-oil-filling eyes with retinal detachment. Conclusion In the silicon-oil-filling eyes with lengthened ocular axis, the characteristics of B-scan images are affected by acoustic velocity through silicon oil, the amount of silicon oil capacity and the emulsification of silicon oil. (Chin J Ocul Fundus Dis,2004,20:349-351)

    Release date:2016-09-02 05:58 Export PDF Favorites Scan
  • Clinical applications of optical fundus imaging technology

    Optical imaging technology of ocular fundus, including fundus fluorescein angiography (FFA), optical coherence tomography (OCT) and fundus autofluorescence (FAF), is growing at an unprecedented speed and scale and is integrating into the routine clinical management of ocular fundus diseases, such as diagnosis, treatment, and mechanism study. While FFA allow us to observe the retinal and choroidal blood circulation, OCT and FAF are non-invasive, fast and quantifiable measurement; such techniques show even more unique advantages and are favored tools. All these retinal imaging technologies, together with a variety of retinal function assessments, bring us into the era of big data of ocular fundus diseases. All of these developments are the challenges and opportunities for the operator and user of these fundus optics imaging technologies. In order to improve its clinical applications and allocate resources rationally, we need to understand the optical properties of these retinal imaging technologies, and standardize diagnosis behavior. This is a continuous learning process needs to continue to explore.

    Release date: Export PDF Favorites Scan
  • Consistency analysis of two fundus photograph reading methods based on stereoscopic color fundus photograph of diabetic retinopathy with macular edema

    ObjectiveTo analyze the consistency of diagnostic results using simple and comprehensive reading methods on stereoscopic color fundus photographs of diabetic retinopathy (DR) with diabetic macular edema (DME). Methods450 sets of 7-field stereoscopic color fundus photographs of DR DME were compared to standard fundus photographs of early treatment and DR study group. The pictures were read by two groups of reader with similar experience. Two strategies were used to make the judgments, including simple reading which based on the color fundus photographs only, and comprehensive reading which based on color fundus photographs, fundus fluorescein angiography (FFA) and optical coherence tomography (OCT). 15 parameters were scored, including micro-aneurysms (MA), intra-retinal hemorrhage (IRH), hard exudates (HE), cotton wood spot (CW), intra-retinal microvascular abnormalities (IRMA), neovascularization on optic disc (NVD), neovascularization elsewhere (NVE), optic fiber proliferation (FPD), fiber proliferation elsewhere (FPE), pre-retinal hemorrhage (PRH), vitreous hemorrhage (VH), retinal elevation (RE), retinal detachment of central macular (RDC), venous beading (VB), Venous leak (VL). The reliability was evaluated using weighted κ(κw) statistic values. According to Fleiss statistical theory, κw≥0.75, consistency is excellent; 0.60≤κw < 0.75, consistency is good; 0.40≤κw < 0.60, consistency is general; κw < 0.40, consistency is poor. ResultsThe κw values of these 15 parameters were 0.22-1.00, 0.28-1.00 for the simple reading and comprehensive reading respectively. For simple reading, the consistency was poor for 8 parameters (MA, NVD, NVE, FPE, PRH, IRMA, VB, VL), general for 3 parameters (CW, FPD, VH), good for 2 parameters (IRH, HE) and excellent for 2 parameters (RE, RDC). For comprehensive reading, the consistency was poor for 2 parameters (NVE, VB), general for 6 parameters (MA, IRH, CW, FPE, IRMA, VL), good for 2 parameters (NVD, HE), excellent for 5 parameters (FPE, PRH, VH, RE, RDC). ConclusionThe comprehensive reading has higher consistency to judge the abnormality parameters of the fundus photographs of DR with DME.

    Release date: Export PDF Favorites Scan
  • Development trend and clinical applications of ocular fundus optical imaging diagnostic technology

    Using optical imaging equipment with different wavelength and computer technology, fundus optical imaging diagnostic techniques can record fundus reflected light, auto fluorescence and emitted light after excitation by external light source in order to observe and analyze the structure and pathological process of retina and choroid. Advances in fundus optical image capture technology (including laser, confocal laser, spontaneous auto-fluorescence, multispectral imaging) and storage and analysis technology, promote this field into a high-definition digital imaging era, with features of rapid, non-invasive, wide-angle three-dimensional multi-level integration, dynamic automatic navigation location tracking and combined application of a variety of optical imaging diagnostic techniques. In order to promote clinical and scientific research of ocular fundus diseases, we need to understand the development trend of optical imaging diagnostic technique, interpret the fundus imaging features appropriately, reasonably chose different inspection techniques, establish standardized diagnosis criteria and continue to expand clinical applications.

    Release date: Export PDF Favorites Scan
  • Applying wide-angle fundus imaging modalities to improve the diagnosis and treatment of ocular fundus diseases

    The hallmark of the recent latest advances in diagnostic fundus imaging technology is combination of complex hierarchical levels and depths, as well as wide-angle imaging, ultra-wide imaging. The clinical application of wide-angle and ultra-wide imaging, not only can reevaluate the role of the peripheral retina, the classification types and treatment modalities of central retinal vein occlusion, and enhance the reliability of diabetic retinopathy screening, improve the classification and therapeutic decision of diabetic retinopathy, and but also can help guide and improve laser photocoagulation. However we must clearly recognize that the dominant role of ophthalmologists in the diagnosis of ocular fundus diseases cannot be replaced by any advanced fundus imaging technology including wide-angle imaging. We emphasize to use the three factors of cognitive performance (technology, knowledge and thinking) to improve the diagnosis of ocular fundus diseases in China.

    Release date: Export PDF Favorites Scan
  • Consistency analysis of optical coherence tomography angiography and fundus fluorescein angiography in the diagnosis of central retinal vein occlusion

    Objective To assess the consistency of diagnostic results using optical coherence tomography angiography(OCTA) and fundus fluorescein angiography(FFA) in the central retinal vein occlusion(CRVO). Methods A retrospective case series of 26 eyes of 26 patients with CRVO. Simultaneous OCTA and FFA were performed in all patients by using 7-standard field of ETDRS to evaluate the microaneurysms, nonperfused areas, optical disc/retinal neovascularization and macular edema. The consistency was evaluated using weightedKappa statistic values.Kappa≥0.75, consistency is excellent; 0.60≤Kappa<0.75, consistency is good; 0.40≤Kappa<0.60, consistency is general;Kappa<0.40, consistency is poor. Results Examined by OCTA, microaneurysms were found in 23 eyes, nonperfused areas in 16 eyes, optical disc/retinal neovascularization in 8 eyes and macular edema in 21eyes. Performed with FFA, 23 eyes were diagnosed to have microaneurysms, 16 eyes have nonperfused, 8 eyes have optical disc/retinal neovascularization, 22 eyes have macular edema. The consistency was excellent for microaneurysms(Kappa=0.772,P<0.01) and optical disc/retinal neovascularization(Kappa=0.766,P<0.01), good for nonperfused areas (Kappa=0.703,P<0.01) and macular edema(Kappa=0.60,P<0.01). Conclusion There is high consistency between OCTA and FFA in the diagnosis of CRVO, OCTA is an effective method in the examination of CRVO.

    Release date: Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content