find Keyword "Digital radiography" 2 results
  • Children Age Dependent Chest Tube Voltage Settings for Optimizing Radiation Dose and Image Quality: A Prospective Clinical Study

    Objective To explore the feasibility of children age dependent chest tube voltage settings for optimizing radiation dose and image quality in digital radiography (DR). Methods Children aged 0 to 14 who visited the First Affiliated Hospital of Xinjiang Medical University from January, 2008 to December, 2010, were divided into the following 5 age groups: 0~, 1~, 3~, 7~, and 11~14-year-old, and each group was then randomly assigned to the optimization and control groups to take DR by computer. DR in automatic exposure control with different tube voltage depending on children age; the control group: DR in automatic exposure control with conventional fixed tube voltage. The dose area product (DAP) was adopted for the measurement of radiation dose, while the visual grading analysis score (VGAS) was for image quality. Then SPSS 17.0 was applied for statistical analysis. Results A total of 2 450 children were initially included. Finally there were 2 415 children included in the anteroposterior chest image in this study, and the other 35 children were excluded for their anatomical characteristics could not be showed due to serious primary diseases. There were 1 202 patients in the optimization group and 1 213 patients in the controlled group. The mean DAP in the optimization group was lower than that in the control group with a significant difference (t= –4.967, P=0.008). The mean VGAS in the optimization group was higher than that in the control group with a significant difference (t= 23.738, P=0.000). Conclusion Children age dependent tube voltage settings can effectively reduce radiation dose and improve image quality at the same time.

    Release date: Export PDF Favorites Scan
  • Optimize Infants Chest Radiation Dose and Image Quality in DR: A Prospective Randomized Controlled Trial

    Objective To optimize image quality and radiation dose of infant chest digital radiography and to explore feasibility of reducing tube voltage and adjusting according to infant chest area. Methods 0 to 3-year-old infants were randomly divided into two average groups of 0- and 1-3 year-old, and then each age group was randomly assigned to optimization and control groups in digital radiography. Measurement of radiation dose used dose area product (DAP). Mean DAP between groups was compared by using t test, and the image quality of optimization was compared by rank sum test. Results A total of 400 cases of 0 to 3-year-old infants were identified, and finally 391 cases of infants anteroposterior chest image were included, including 196 cases in the optimization group (0-years: n=91; 1-3 years: n=105) and 195 cases in the control group (0-years: n=103; 1-3 years: n=92). The results showed: there were significant differences in the mean DAP in 0-years, 1-3 years and total infants between the optimization group and the control group (all P valuelt;0.05). The DAP of the optimization group was lower, and reduction of DAP was approximately 21.6% compared to the control subject. The Wilcoxon signed-rank test showed the difference of subjective evaluation of image quality was significantly different (P=0.000). High-quality image of the optimization group increased approximately 43.9% more than control subject. Conclusion Reducing tube voltage and adjusting according to infants chest area can not only reduce the radiation dose but also improve image quality in digital radiography.

    Release date:2016-09-07 11:01 Export PDF Favorites Scan