west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "Doppler ultrasonography" 7 results
  • Study on The Effect of Endovascular Treatment Guided by Ultrasonography Combined with Portosystemic Shunts for Budd-Chiari Syndrome

    Objective To explore the effect of endovascular treatment guided by ultrasonography combined with portosystemic shunts on the patients with Budd-Chiari Syndrome (BCS).Methods The clinical data of 136 patients with BCS treated by balloon angioplasty and stent implantation guided by Doppler ultrasonography in our hospital from January 1995 to January 2011 were retrospectively analyzed.After balloon angioplasty,53 patients were treated by inferior vena cava (IVC) stent implantation and 31 patients with hepatic venous occlusion underwent portosystemic shunts (PSSs) at one week after endovascular treatment.The long-and short-term effects after treatment were studied.Results After endovascular procedures,the IVC pressure of patients significantly decreased (P<0.01),while IVC diameter, flow velocity in the lesion,and right atrial pressure of patients showed significant increase(P<0.01).Slight heart dysfunction appeared in 13 cases of patients.After shunting,acute pancreatitis occurred in 3 cases, and 1 patient died of upper gastrointestinal hemorrhage on the 10 d after PSSs.Doppler ultrasonography for IVC and shunt vessels showed:the swollen liver and spleen lessened on 3d after endovascular procedures.The swollen liver lessened 2-7cm (mean 5.5cm),swollen spleen lessened 3-8cm (mean 5.8cm), and the time of ascites disappearance was 3-60d (mean 14d).All the patients were followed up for 1 month to 15 years with an average of 3 years.Restenosis of the distal part of stent was found in 1 patient in 2 years after operation, hepatic vein occlusion occurred in 1 case in 1 year after treatment,hepatocellular carcinoma occurred in 1 patient in 3 years after stent implantation,and 1 patient died of C type hepatitis after 1 year,and 5 out of 6 cases of patients with infertility had babies after 1 year.All patients had no stent migration or occlusion of shunts and the symptoms of portal hypertension were obviously relieved.Conclusions Endovascular treatment guided by Doppler ultrasonography is a convenient,safe,and effective method for BCS.Portosystemic shunts are commended to patients with hepatic venous occlusions.The above mentioned methods provide a feasible and effective means for IVC stenosis and short segment occlusion with hepatic vein occlusion of BCS.

    Release date: Export PDF Favorites Scan
  • DIAGNOSIS AND TREATMENT OF SUBCUTANEOUS CAVERNOUS HEMANGIOMA WITH COLOR DOPPLER ULTRASONOGRAPHY

    OBJECTIVE: To discuss clinical application of the color Doppler ultrasonography in diagnosis and treatment of cavernous hemangioma in deep subcutaneous tissue. METHODS: From 1996, 15 cases of cavernous hemangioma were diagnosed and located with color Doppler ultrasonography and were embolized under monitoring of the ultrasonography or resected by operation before re-examination of the hemangioma via the color Doppler ultrasonography after the intervention. RESULTS: Direct embolization was achieved in 10 cases after pinpoint location of the hemangioma by the ultrasonography, and guided embolization was performed successfully in 2 cases via the monitoring of ultrasonography, and operation had to be adopted to remove the focus. No reoccurrence of the hemangioma was observed in all the cases. CONCLUSION: Cavernous hemangioma in deep subcutaneous tissue could be easily diagnosed and located with color Doppler ultrasonography, and could be removed by embolization under monitoring of the ultrasonography successfully.

    Release date: Export PDF Favorites Scan
  • Value of Color Doppler Ultrasonography and Plasma D-imer in Diagnosis of Lower Limb Venous Thrombosis

    Objective To explore the value of color Doppler ultrasonography and plasma D-dimer in diagnosis of lower limb deep venous thrombosis (DVT).Methods The clinical data of 70 cases of patients with lower limb DVT diagnosed clinically were retrospectively studied. The lower limb venous of each patient was examined by color Doppler ultrasonography and the plasma level of D-dimer were measured, furthermore the plasma levels of D-dimer in different phase and different type of thrombosis were compared. Results The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of plasma D-dimer and ultrasonography examination in lower limb DVT were 100%, 66.7%, 97.0%, 100%, and 97.1%, and 98.4%, 83.3%, 98.4%, 83.3%, and 97.1%, respectively. The plasma D-dimer in acute phase 〔(6 451±4 012.22) μg/L〕 and subacute phase 〔(2 063±1831.35) μg/L〕 of lower limb venous thrombosis were significantly higher than that in normal control group 〔(310±66.70) μg/L〕, Plt;0.01 and Plt;0.05, which was not different from that in chronic phase 〔(466±350.52) μg/L〕. Meanwhile, the plasma D-dimer in mixed limb venous thrombosis group 〔(4 464±3 753.16) μg/L〕 and central limb venous thrombosis group 〔(2 149±1 911.53) μg/L〕 were significantly higher than that in control group (Plt;0.05 and Plt;0.01), which was not different from that in peripheral limb venous thrombosis group 〔(560±315.62) μg/L〕. Conclusion Color Doppler ultrasonography is an optimal method and the plasma D-dimer is a predictive index in diagnosis of lower limb DVT.

    Release date:2016-09-08 10:54 Export PDF Favorites Scan
  • Application of MRA, IPVG and DUS in Hemodynamics Evaluation for Portal Hypertension

    【Abstract】ObjectiveTo evaluate the role of MRA, IPVG and DUS in the hemodynamics studies of portal hypertension. MethodsThirtyeight patients with portal hypertension were examined with Philips Gyroscan 1.0 Tesla MR imaging system. 3DDCE MRA and 2DPC MR were used for study of portal venous anatomy and its hemodynamics. The results were compared with those obtained from IPVG and DUS. Results3DDCE MRA could clearly display the anatomical imaging of portal venous system and its imaging quality was better than that of IPVG. The data of hemodynamics from 2DPC MR including diameter, blood velocity and blood flow were closely correlated to those from DUS. ConclusionAs a noninvasive technique, MRA can display the anatomy of portal venous system and measure its hemodynamics exactly. It should be applied as the first choice in hemodynamics evaluation for portal hypertension.

    Release date:2016-09-08 11:52 Export PDF Favorites Scan
  • The Value of High-frequency Color Doppler Ultrasonography in the Diagnosis of Femoral Hernia

    ObjectiveTo evaluate the value of high-frequency color Doppler ultrasonography in the diagnosis of femoral hernia. MethodsThe ultrasonographic features of 39 femoral hernias in 37 patients treated between March 2008 and October 2013 were retrospectively analyzed, and the results were confirmed by surgery. ResultsThirty-nine femoral hernias were diagnosed by surgery, including 19 in the right side, 16 in the left side, and 2 with double-side hernias. Thirty-seven femoral hernias were diagnosed with ultrasonography. Two femoral hernias were misdiagnosed as lipoma in one, and as enlarged lymph nodes in one, respectively. Ultrasound diagnosis accurate rate was 94.9% (37/39). Hernia content could be seen through surgery in 28 cases, and the ultrasound accurate rate in assessing the hernia content was 85.7% (24/28). ConclusionUltrasonography is the first choice for improving the diagnosis efficacy of femoral hernia.

    Release date: Export PDF Favorites Scan
  • A comparative study on color Doppler ultrasonography and X-ray antegrade venography in diagnosis of lower extremity perforating venous valve insufficiency

    Objective To investigate the value of color Doppler ultrasonography in the examination of perforating veins of the lower extremities by comparing with X-ray antegrade venography. Methods Fifty-three patients (60 lower extremities) clinically diagnosed with varicosis of the great saphenous vein from January 2014 to March 2016 were selected for color Doppler ultrasonography and X-ray antegrade venography. The results were compared and confirmed by surgery. Results Forty-seven lower extremities were diagnosed with perforating venous valve insufficiency by color Doppler ultrasonography, while 50 lower extremities by X-ray antegrade venography. There was no significant difference between the two methods (χ2=0.800, P=0.371). A total of 78 perforating veins were detected by color Doppler ultrasonography, with 1–4 perforating veins per one lower extremity. Among them, 66 perforating veins had an internal diameter of 2–5 mm, accounting for 84.6%. Except two perforating veins with an internal diameter <2 mm, the rest showed reflux. In addition, a total of 73 perforating veins presented distance to the pelma of 10–32 mm (foot-boot), accounting for 93.6%. Fifty-two lower extremities with varicosis of the great saphenous vein underwent laser ablation of the great saphenous vein with high ligation or + devascularization of perforating veins. Compared with operation findings, color Doppler ultrasonography in diagnosis of perforating venous valve insufficiency had 37 true positives, 2 false positives, 10 true negatives and 3 false negatives, and the sensitivity was 92.5% (37/40), the specificity was 83.3% (10/12), the accuracy rate was 90.4% (47/52). Conclusions Color Doppler ultrasonography can accurately localize perforating veins, measure the internal diameter and observe the degree of reflux. It is of high sensitivity and accuracy in the diagnosis of perforating venous valve insufficiency. Moreover, it is safe, simple and economical, and suitable for preoperative and intraoperative diagnosis and localization.

    Release date:2017-11-24 10:58 Export PDF Favorites Scan
  • Analysis of color Doppler flow imaging features of familial exudative vitreoretinopathy

    ObjectiveTo analyze the color Doppler flow imaging (CDFI) features of familial exudative vitreoretinopathy (FEVR) at different stages. MethodsA retrospective study. A total of 104 patients with 201 eyes from Department of Ophthalmology of Beijing Tongren Hospital who were hospitalized for fundus examination and diagnosed with FEVR from 2018 to 2022 were included. There were 69 male cases with 133 eyes and 35 female cases with 68 eyes. The age was ranged from 2 months to 11 years, with a mean age of 2.9 years. Fundus and CDFI examination were performed in both eyes. Fluorescein fundus angiography was performed in 72 cases (144 eyes). FEVR staging was conducted according to literature standards. The presence of avascular areas in the peripheral retina or abnormal retina neovascularization was stage 1; the presence of retinal neovascularization at the vitreoretinal interface in the avascular area was stage 2; partial retinal detachment without macula involvement was stage 3; partial retinal detachment involving the macula was stage 4; complete retinal detachment was stage 5. The CDFI ultrasound features of FEVR at different stages were analyzed. The CDFI image features of FEVR patients in different stages were observed. ResultsAmong the 104 patients, 97 (93.3%, 97/104) cases were binocular and 7 (6.7%, 7/104) cases were monocular. In 201 eyes, stages 1 to 5 of FEVR were 49 (24.4%, 49/201), 23 (11.4%, 23/201), 39 (19.4%, 39/201), 71 (35.3%, 71/201), and 19 (9.5%, 19/201) eyes, respectively. CDFI examination showed no abnormality or mild vitreous opacity in 49 eyes vitreous body at stage 1. Vitreous opacities were observed in all 23 eyes in stage 2, and the echo of the temporal ballwall was not smooth. In 39 eyes at stage 3, the anterior globular cluster echo in temporal peripheral eyes was observed in 17 eyes and partial retinal detachment was observed in 13 eyes. In 71 eyes at stage 4, 51 eyes had temporal or infratemporal retinal folds, and 20 eyes had temporal retinal detachment. All the 19 eyes in stage 5 had total retinal detachment, of which 15 eyes had closed "funnel-shaped" retinal detachment. Retinal folds were found in 51 eyes, 26 eyes in 13 cases. There were vitreous opacities in 25 eyes of 25 monocular cases, and the contralateral eye had different degrees or banded echoes in front of the temporal eye. Blood flow signals could be detected on the retinal folds with Doppler imaging. ConclusionsThe CDFI manifestations of FEVR patients at different stages have different characteristics. The possibility of FEVR should be considered when the temporal or infratemporal retinal folds of both eyes are present, as well as the retinal folds of one eye, the contralateral vitreous body opacity, or the anterior temporal peribulbar cluster echoes are present.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content