ObjectiveTo compare the effectiveness of triple Endobuttons and clavicular hook plate fixation in the treatment of fresh acromioclavicular joint dislocation (Rockwood type III-V). MethodsBetween February 2008 and October 2010, 40 patients with fresh acromioclavicular joint dislocation (Rockwood type III-V) were treated with triple Endobuttons in 18 cases (trial group) and with clavicular hook plate in 22 cases (control group). There was no significant difference in gender, age, disease duration, joint dislocation classification, preoperative visual analogue scale (VAS) score and Constant-Murley score between 2 groups (P gt; 0.05). ResultsAfter operation, wound healed by first intention with no early complication of infection or neurovascular injury. The patients were followed up 12-20 months (mean, 15.8 months) in trial group and 13-24 months (mean, 17.2 months) in control group. Significant differences were found in the VAS score and Constant-Murley score at the last follow-up between 2 groups (P lt; 0.05). X-ray films showed no loosening of internal fixators or hook displacement occurred. No re-dislocation was observed. ConclusionTriple Endobuttons has less shoulder pain and better shoulder motion than clavicular hook plate, so it is an effective method of treating Rockwood type III-V fresh acromioclavicular joint dislocation.
ObjectiveTo evaluate and compare the effectiveness of double Endobutton technique and suture anchor combined Endobutton plate in the treatment of Tossy type Ⅲ acromioclavicular joint dislocation. MethodsBetween May 2010 and March 2014, a retrospective study was preformed on 56 patients with Tossy type Ⅲ acromioclavicular joint dislocation. The coracoclavicular ligament was reconstructed with double Endobutton technique in 31 cases (Endobutton group), and with suture anchor combined Endobutton plate in 25 cases (Anchor group). There was no significant difference in age, gender, injury causes, injury side, associated injury, medical comorbidities, and disease duration between 2 groups (P>0.05). The operation time, medical device expenses, postoperative complications, preoperative and postoperative Constant-Murley scores, and postoperative Karlsson grading of the injured shoulder were compared between 2 groups. ResultsThe average operation time in Endobutton group was significantly greater than that in Anchor group (t=4.285, P=0.000); there was no significant difference in the medical device expenses between 2 groups (t=1.555, P=0.126). Primary healing of incision was obtained in all patients of 2 groups; no early complications of infection and skin necrosis occurred. All patients were followed up 15.6 months on average (range, 11-35 months). During follow-up, some loss of reduction and ectopic ossification in the coracoclavicular gap were observed in 1 case and 6 cases of Endobutton group, respectively. No recurrence of acromioclavicular joint dislocation, implant fixation loosening and broken, and secondary fractures occurred in the other patients. There was significant difference in the incidence of postoperative complications between 2 groups (P=0.013). Constant-Murley scores of the injured shoulder significantly increased at 9 months after operation when compared with preoperative values in 2 groups (P<0.05), but no significant difference was observed between 2 groups (P>0.05). At last follow-up, there was no significant difference in Karlsson grading between 2 groups (Z=-0.628, P=0.530). ConclusionBoth double Endobutton technique and suture anchor combined Endobutton plate have good effectiveness in the treatment of Tossy type Ⅲ acromioclavicular joint dislocation. But the latter is associated with easier operation, less operation time, and less complications.
ObjectiveTo investigate the short-term effectiveness of arthroscopic assisted double Endobutton “8” buckle fixation in the treatment of Rockwood Ⅲ type acute acromioclavicular joint dislocation.MethodsThe clinical data of 12 patients with Rockwood Ⅲ type acute acromioclavicular joint dislocation who were treated with arthroscopic assisted double Endobutton “8” buckle fixation between June 2016 and June 2019 were analyzed retrospectively. There were 8 males and 4 females, with an average age of 47.0 years (range, 36-58 years). There were 4 cases of left shoulder and 8 cases of right shoulder. The causes of injury included traffic accident injury in 7 cases and falling injury in 5 cases. The average time from injury to operation was 5.0 days (range, 3-14 days). Before operation and at last follow-up, the shoulder joint activity was recorded; the improvements of function and pain were evaluated by Constant score and visual analogue scale (VAS) score, respectively; the reduction was evaluated by measuring the coracoid spacing of the affected side on the anteroposterior X-ray film of shoulder joint.ResultsAll 12 cases were followed up 6-36 months, with an average of 20.6 months. All the incisions healed by first intention. There was no complications such as clavicle and coracoid fractures and Endobuton displacement. At last follow-up, the range of motion of the abduction improved from preoperative (77.5±4.5)° to (162.5±6.5)°, the range of motion of forward flexion improved from (84.1±5.2)° to (169.5±5.8)°, the Constant score improved from 42.5±2.3 to 92.4±2.3, the VAS score improved from 5.4±0.8 to 0.6±0.5, and the coracoid spacing reduced from (20.5±1.4) mm to (9.2±0.6) mm, all showing significant differences (P<0.05).ConclusionArthroscopic assisted double Endobutton “8” buckle fixation for the treatment of Rockwood Ⅲ type acute acromioclavicular joint dislocation is safe, less invasive, and quicker recovery. It can effectively alleviate shoulder pain, significantly improve the mobility of the shoulder joint, and achieve good short-term effectiveness.
ObjectiveTo observe the short-term effectiveness of Endobutton plate in the reconstruction of Lisfranc ligament in tarsometatarsal joint injury.MethodsBetween March 2015 and July 2018, 18 patients with tarsometatarsal joint injuries were treated with Lisfranc ligament reconstruction by Endobutton plate. There were 12 males and 6 females with an average age of 32.5 years (range, 16-55 years). The causes of injury were traffic accident in 8 cases, falling from height in 3 cases, crushing by a heavy objective in 4 cases, and spraining in 3 cases. There were 10 cases of Myerson type A, 4 of type B1, 2 of type B2, 1 of type C1, and 1 of type C2. The interval between injury and operation ranged from 3 to 9 days (mean, 4.9 days). X-ray examination was performed regularly after operation to measure the distance between the first and the second metatarsal joints, and the visual analogue scale (VAS) score was used to evaluate the pain relief. At last follow-up, the reduction of tarsometatarsal joint was evaluated by measuring and comparing the height of the affected and healthy arches. The foot function was evaluated according to the American Orthopaedic Foot and Ankle Society (AOFAS) score.ResultsThe average follow-up time was 15.8 months (range, 10-28 months). All incisions healed by first intention. X-ray reexamination showed that there was no screw loosening or plate fracture. There were significant differences in the distance between the first and the second metatarsal joints and VAS score at 3 months after operation, before removal of the internal fixator, and at last follow-up when compared with preoperative values (P<0.05). There was no significant difference between the time points after operation (P>0.05). At last follow-up, there was no significant difference in the arch height between affected foot [(5.3±0.2) mm] and healthy foot [(5.4± 0.3) mm] (t=1.798, P=0.810). The AOFAS score of foot function was 89.5±7.3 with excellent in 12 cases, good in 4 cases, and fair in 2 cases. The excellent and good rate was 88.9%.ConclusionThe reconstruction of Lisfranc ligament with Endobutton plate can stabilize the tarsometatarsal joint and achieve satisfactory foot function at early stage.
ObjectiveTo investigate the effectiveness of Endobutton plate coracoclavicular fixation combined with fracture site high-strength suture Nice knot cerclage fixation in the treatment of distal clavicle fracture with coracoclavicular ligament injury. Methods The clinical data of 33 cases of distal clavicular fracture with coracoclavicular ligament injury treated by Endobutton coracoclavicular plate fixation between January 2017 and December 2020 were analyzed retrospectively. According to the fixation methods of fracture site, they were divided into two groups: the high-strength suture Nice knot fixation group (study group, 16 cases) and the transacromial Kirschner wire fixation group (control group, 17 cases). There was no significant difference between the two groups in common data such as age, gender, injury side, cause of injury, Craig type, combined injury, time from injury to operation, and preoperative visual analogue scale (VAS) score and Constant-Murley score (P>0.05). Postoperative fracture healing and complications were observed, and the increase rate of coracoclavicular space on the affected side was calculated at last follow-up. VAS score was used to evaluate shoulder pain before operation, at 1 week, 1 month, 3 months after operation, and at last follow-up. The shoulder function was evaluated according to Constant-Murley shoulder score before operation, at 1 month, 3 months after operation, and at last follow-up. Results The operations were successfully completed in both groups without severe complications such as vascular nerve injury and coracoid fracture. In the control group, 1 case (5.9%) had slight pin tract infection and 1 case (5.9%) had Kirschner wire displacement; there was no obvious complication in the study group. The patients in both groups were followed up 9-36 months (mean, 22.9 months). The fracture healing time of the study group and the control group were (12.56±0.73) weeks and (13.59±0.87) weeks, respectively, and the difference was significant (t=−3.661, P=0.001). At last follow-up, the increase rates of coracoclavicular space on the affected side of the study group and the control group were 8.88%±1.19% and 8.55%±1.07%, respectively, showing no significant difference (t=0.837, P=0.409). The postoperative VAS score and Constant-Murley score of the two groups significantly improved when compared with those before operation, and the two scores gradually improved with the extension of time after operation (P<0.05). Except that the VAS score at 1 week and 1 month after operation and the Constant-Murley score at 1 month after operation in the study group were significantly better than those in the control group (P<0.05), there was no significant difference between the two groups at other time points after operation (P>0.05). Conclusion For oblique fracture or combined with butterfly fracture in the distal clavicle fracture with coracoclavicular ligament injury, the fracture site high-strength suture Nice knot fixation is a good supplement to the Endobutton plate coracoclavicular fixation. It can stabilize the fracture end, reduce the complications of Kirschner wire fixation, and is more conducive to fracture healing. The effectiveness is satisfactory.
【Abstract】 Objective To evaluate the early result of tri ple Endobutton technique for reconstructing coracoclavicularligament of chronic complete acromioclavicular joint dislocations. Methods Between January 2009 and June 2010, 14 patients with chronic complete acromioclavicular joint dislocations were treated with tri ple Endobutton technique for reconstructing coracoclavicular ligament. There were 10 males and 4 females with a mean age of 38.5 years (range,26-52 years). Injury was caused by traffic accident in 7 cases,by falling in 5 cases,and by bruise in 2 cases. The average time was 47 days from injury to the operation (range,29-75 days). All patients had pain and activity restriction. The X-ray films showed complete dislocation of acromioclavicular joint. According to Allman’s type, all cases were classified as III degree complete dislocations. Results At postoperation, wound healed by first intention with no early complication of infection or neurovascular injury. All patients were followed up 18.3 months on average (range,13-30 months). Acromioclavicular joint subluxation occurred in 1 patient at 1 week after operation, and no redislocation or other complication occurred in the other patients. American Shoulder and Elbow Surgeons (ASES) score was 90.8 ± 4.1 at last follow-up, showing significant difference when compared with the preoperative score (65.3 ± 4.4) (t= —17.57,P=0.00); Constant-Murley score was 91.7 ± 3.9, showing significant difference when compared with preoperative one (71.5 ± 4.6) (t=—75.02,P=0.00). The definite answer in Simple Shoulder Test (SST) averaged 9.7 (range,7-12). Conclusion The tri ple Endobutton technique for reconstructing coracoclavicular ligament is an effective method in treatment of chronic complete acromioclavicular joint dislocations. The short-term results are satisfactory.
Objective To investigate the effectiveness of arthroscopic suspension fixation with Endobutton in the treatment of tibial insertion avulsion fractures of posterior cruciate ligament (PCL). Methods A retrospective analysis was conducted on the clinical data of 52 patients (52 knees) with tibial insertion avulsion fractures of PCL, who were treated by arthroscopic suspension fixation with Endobutton between June 2017 and October 2022. There were 29 males and 23 females, with an average age of 40.6 years (range, 19-66 years). There were 24 cases of traffic accident injuries, 17 cases of sports injuries, and 11 cases of fall injuries. The time from injury to operation ranged from 6 to 19 days (mean, 13.3 days). According to the Meyers-McKeever classification, there were 30 cases of type Ⅱ and 22 cases of type Ⅲ fractures. All patients exhibited positive posterior drawer test results. Preoperative knee joint function was assessed with Lysholm score (21.3±6.7), International Knee Documentation Committee (IKDC) score (20.7±5.8), and visual analogue scale (VAS) score (5.3±0.7); and knee joint range of motion was (41.73±3.17)°. Based on preoperative CT three-dimensional reconstruction measurements, the longitudinal diameter of the avulsed bone fragment ranged from 13 to 25 mm (mean, 18.1 mm). Operation time and occurrence of complications were recorded, and postoperative imaging was used to assess fracture healing. Knee joint function and pain severity were evaluated using knee joint range of motion, Lysholm score, IKDC score, and VAS score. Results The operation time ranged from 46 to 81 minutes (mean, 56.2 minutes). All patients were followed up 12-28 months (mean, 20.1 months). The iatrogenic fractures of bone fragments occurred during operation in 4 cases; and knee effusion occurred in 2 cases and anterior knee pain in 1 case after operation. All incisions healed by first intention. Imaging evaluations at 3 months after operation showed the fracture healing and no internal fixation failure. All patients demonstrated good knee function and had returned to normal activities at 12 months after operation. At last follow-up, the knee joint range of motion was (133.44±4.17)°, Lysholm score 93.6±3.1, IKDC score 93.4±2.5, and VAS score 1.0±0.6, with significant differences compared to preoperative scores (P<0.05). Conclusion Arthroscopic suspension fixation with Endobutton in the treatment of tibial insertion avulsion fractures of PCL is simple to operate, and the knee joint function recovers well.