west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "Endoleak" 4 results
  • Intra-Sac Pressure Measurement of Abdominal Aortic Aneurysm to Reveal The Characters of All Types of Endoleak

    Objective To review and compare the literatures on studying endoleak via intra-sac pressure (Psac) measurement in order to reveal the characters of all types of endoleak. Methods Measured the intra-sac pressure with miscellaneous pressure transducers in vitro and in vivo endoleak models or patients afflicted with endoleak. Compared the difference of Psac among no endoleak and all types of endoleak. Results Psac>0 but was obviously lower than Psys in no endoleak. Psac approached Psys in type Ⅰ and type Ⅳ endoleaks. Some researches showed that Psac in type Ⅱ endoleak was higher than that in no endoleak and even approached Psys, however the other researches showed that Psac in type Ⅱ endoleak was lower than that in no endoleak. Conclusion Postoperative Psac dropping greatly eliminated the risk of aneurysm rupture, which symbolized the success of endovascular therapy. Even if the type Ⅰ endoleak of small size might lead to obvious elevation of Psac, which necessitates management. The impairment and management tactics of type Ⅱ endoleak remained equivocal, which required further study.

    Release date: Export PDF Favorites Scan
  • ANALYSIS OF ENDOLEAK IN SHORT TERM AFTER ENDOVASCULAR ANEURYSM REPAIR FOR ABDOMINAL AORTIC ANEURYSMS

    Objective To observe the occurrence condition of endoleak after endovascular aneurysm repair (EVAR) operation for abdominal aortic aneurysm (AAA), and to analyze the factors of the endoleak. Methods Between July 2005 and June 2013, 210 cases of AAA were treated with EVAR. Of 210 patients, 175 were male and 35 were female, aging 42-89 years (mean, 65.7 years). The patients were all proved to have infrarenal AAA by computed tomography angiography (CTA). The disease duration ranged from 1 week to 2 years (median, 11.3 weeks). The maximum diameter of the aneurysms was 44-72 mm (mean, 57.3 mm). The proximal landing zone was longer than 1.5 cm. CTA was performed routinely at 2 months after operation to detect the endoleak of contrast agent. If endoleak was found, CTA was performed again at 6 months. If obvious endoleak still existed, digital subtraction angiography (DSA) would be performed to clarify the character and the degree of the endoleak, and EVAR should be done if necessary. Results Endoleak occurred in 31 cases (14.8%) during operation, including 11 cases of type I endoleak (8 cases of type IA and 3 cases of type IB), 18 cases of type II endoleak, and 2 cases of type III endoleak (type IIIB). The patients were followed up 2-8 months (mean, 3.1 months). At 2 months after operation, contrast agent endoleak was found in the remnant aneurysm cavity of 12 cases (5.7%). At 6 months after eperation, contrast agent endoleak was found in 10 cases (4.8%) by CTA. In 8 patients receiving DSA, there were 4 cases of type I endoleak (3 cases of type IA and 1 case of type IB), 3 cases of type II endoleak, and 1 case of type III (type IIIB) endoleak. In 5 patients having type I and type III endoleak, collateral movement of stent graft was observed in different degree; after increased stent graft was implanted, the endoleak disappeared after 2-4 months. The patients having type II endoleak were not given special treatment, endoleak still existed at 2 months after reexamination of CTA, but the maximum diameter of AAA had no enlargement. Conclusion The collateral movement of stent graft is a very important factor to cause type I and type III endoleak in the patients of AAA after EVAR, and endoleak can be plugged by EVAR again.

    Release date:2016-08-31 04:05 Export PDF Favorites Scan
  • Diagnosis and Treatment for Endoleaks after Endovascular Repair of Abdominal Aortic Aneurysm

    ObjectiveTo explore the progresses of diagnosis and treatment for endoleaks after endovascular repair of abdominal aortic aneurysm (EVAR). MethodsThe literatures on studying the classification, diagnosis and management, risk factor, and treatment for the endoleaks after EVAR were reviewed and analyzed. ResultsEndoleak was a common and particular complication after EVAR and its represented persistence meant failure of the EVAR treatment. Accurate detection and classification were essential for the proper management and the treatment method for the endoleak was determined by the different source. Type Ⅰ and type Ⅲ endoleak required urgent treatment, type Ⅱ and type Ⅴ were considered less urgently but may be observed continuously. A variety of techniques including extension endografts or cuff, balloon angioplasty, bare stents, and a combination of transvascular and direct sac puncture embolization techniques were allowed to treat the vast majority of these endoleaks. ConclusionsEndoleak after EVAR is still the main clinical problem to be solved. The characters of endoleak still are not fully revealed. The diagnosis and treatment remained equivocal, which requires further study.

    Release date:2016-09-08 10:40 Export PDF Favorites Scan
  • Influence of Proximal Aneurysm Neck Anatomy on TypeⅠA Endoleak Following Endova-scular Repair for Infrarenal Abdominal Aortic Aneurysm

    ObjectiveTo determine the influence of proximal aneurysm neck anatomy on typeⅠA endoleak follo-wing endovascular aortic aneurysm repair (EVAR) for infrarenal abdominal aortic aneurysm. MethodsFrom September 2007 to February 2014, 111 consecutive patients with non-ruptured abdominal aortic aneurysms were treated with EVAR. The preoperative CTA of abdominal aortic was obtained by every patient, and the three-dimensional imaging was reconstructed and measured by software of Osorix. Then, the relation between the recurrence of typeⅠA endoleak and the concerned data measured by Osorix was analyzed by the statistical software. ResultsThe recurrence of typeⅠA endo-leak was related to the proximal neck angle of the abdominal aortic aneurysm, which weren't related to the proximal neck diameter and variation rates, the mural thrombas and calcification rate, and the maximum diameter of abdominal aortic aneurysm by multivariate analysis. ConclusionsThe complicated proximal aneurysm neck anatomy is a major cause for the typeⅠA endoleak, the proximal neck angle of the abdominal aortic aneurysm is the independent factor. The applica-tion of EVAR depends largely on the shape of the proximal aneurysm neck.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content