west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "Entry point" 2 results
  • ANATOMIC STUDY ON ENTRY POINT AND IMPLANT TECHNIQUE FOR C2 PEDICLE SCREW FIXATION

    ObjectiveTo determine the entry point and screw implant technique in posterior pedicle screw fixation by anatomical measurement of adult dry samples of the axis so as to provide a accurate anatomic foundation for clinical application. MethodsA total of 60 dry adult axis specimens were selected for pedicle screws fixation. The entry point was 1-2 mm lateral to the crossing point of two lines: a vertical line through the midpoint of distance from the junction of pedicle medial and lateral border to lateral mass, and a horizontal line through the junction between the lateral border of inferior articular process and the posterior branch of transverse process. The pedicle screw was inserted at the entry point. The measurement of the anatomic parameters included the height and width of pedicle, the maximum length of the screw path, the minimum distance from screw path to spinal canal and transverse foramen, and the angle of pedicle screw. The data above were provided to determine the surgical feasibility and screw safety. ResultsThe width of upper, middle, and lower parts of the pedicle was (7.35±0.89), (5.50±1.48), and (3.97±1.01) mm respectively. The pedicle height was (9.94±1.16) mm and maximum length of the screw path was (25.91±1.15) mm. The angle between pedicle screw and coronal plane was (26.95±1.88)° and the angle between pedicle screw and transverse plane was (22.81±1.61)°. The minimum distance from screw path to spinal canal and transverse foramen was (2.72±0.83) mm and (1.98±0.26) mm respectively. ConclusionAccording to the anatomic research, a safe entry point for C2 pedicle screw fixation is determined according to the midpoint of distance from the junction of pedicle medial and lateral border to lateral mass, as well as the junction between the lateral border of inferior articular process and the posterior branch of transverse process, which is confirmed to be effectively and safely performed using the entry point and screw angle of the present study.

    Release date:2016-08-25 10:18 Export PDF Favorites Scan
  • AN ANATOMIC STUDY OF LAG SCREW PLACEMENT IN ANTERIOR COLUMN OF ACETABULUM AND DESIGN OF TARGETING DEVICE

    Objective To provide the anatomic basis for thelag screw placement in the anterior column of the acetabulum. Methods Twenty-two pelvis specimens with 44 acetabula of the native adult cadavers were studied. The anthropometric measurement was performed on 44 acetabula to determine the shape of the transverse section of the anterior column of the acetabulum, the optimal entry point for the lag screw on the outer table of the ilium, the direction of the screw, and the distance from the entry point to the obturator groove. Results The transverse section of the anterior column of the acetabulum was almost triangle-shaped. The path for the lag screw placement was 10.5±0.8 mm in diameter. The optimal entry point on the posterolateral ilium for the screw fixation was found toexist 9.2±2.4 mm superior to the line between the anterior superior iliac spine and the greater sciatic notch and 38.5±3.8 mm superior to the greater sciatic notch. The distance from the entry point to the obturator groove was 84.1±6.2 mm. The inclination of the lag screw was 54.2±5.5° at the caudal direction in the sagittal plane and 40.7±3.8° in the horizontal plane. The device for the safe screw placement in the anterior column was designed. Conclusion The above datacan facilitate an insertion of one 6.5 mm lag screw into the anterior acetabular column and minimize the risk of articular violation or cortical penetration, which has a narrow margin of safety. The safe length of the lag screw should be 70 mm.The optimal entry point on the posterolateral ilium for the screw fixationis determined to be 10 mm superior to the line between the anterior superior iliac spine and the greater sciatic notch and 40 mm superior to the greater sciatic notch. The inclination of the lag screw should be 55° at the caudal direction in the sagittal plane and 40° in the horizontal plane. It is safe to place thelag screw in the anterior column with the help of the targeting device.

    Release date:2016-09-01 09:26 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content