west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "FU Bingqi" 2 results
  • Preliminary clinical outcomes of the domestic Renatus® balloon-expandable valve system for the treatment of severe aortic stenosis: A prospective cohort study

    Objective To evaluate the early clinical outcomes of the Renatus® balloon-expandable valve in the treatment of severe aortic stenosis. MethodsFrom November 2021 to April 2022, a total of 38 patients who received Renatus® balloon-expandable valve for severe aortic stenosis in Guangdong Provincial People's Hospital were included. There were 22 males and 16 females, with an average age of 73.7±5.3 years. Mean aortic gradient and peak aortic jet velocity at baseline, post-procedure, and follow-up were compared. Clinical outcomes including all-cause mortality, perivalvular leakage, serious adverse cardiovascular events and the occurrence of permanent pacemaker implantation were assessed. ResultsAll patients completed the procedure successfully without conversion to thoracotomy or perioperative death. The post-implant mean aortic pressure gradient was decreased from 41.5 (27.8, 58.8) mm Hg to 6.0 (3.0, 8.0) mm Hg, and the peak aortic jet velocity was also decreased from 4.1±0.9 m/s to 1.7±0.4 m/s (P<0.001). Pacemakers were required in 2 (5.3%) patients. The median follow-up time was 27.5 (23.0, 87.5) d, with a follow-up rate of 100.0%. The mean aortic gradient was 8.0 (7.0, 10.8) mm Hg and peak aortic jet velocity was 2.0±0.3 m/s, showing significant improvement compared with those in the preoperative period (P<0.001). No severe aortic regurgitation or paravalvular leak was observed. There was no serious cardiovascular adverse event or reoperative event during the study period. ConclusionTranscatheter aortic valve replacement with the domestic Renatus® balloon-expandable valve system is a safe and effective procedure for selected patients with severe aortic stenosis who are at high risk or not candidates for surgical aortic valve replacement.

    Release date: Export PDF Favorites Scan
  • Early clinical outcomes of the domestic KokaclipTM transcatheter edge-to-edge mitral valve repair system for severe degenerative mitral regurgitation: A single-arm, prospective, single-group target value clinical trial

    Objective To summarize and analyze the preliminary clinical outcomes of the KokaclipTM transcatheter edge-to-edge mitral valve repair system for severe degenerative mitral regurgitation (DMR). Methods This study was a single-arm, prospective, single-group target value clinical trial that enrolled patients who underwent the KokaclipTM transcatheter edge-to-edge repair (TEER) system for DMR in the Department of Heart Surgery of Guangdong Provincial People's Hospital, Guangdong Cardiovascular Institute from June 2022 to January 2023. Differences in the grade of mitral regurgitation (MR) during the perioperative and follow-up periods were compared, and the incidences of adverse events such as all-cause death, thoracotomy conversion, reoperation, and severe recurrence of MR during the study period were investigated. Results The enrolled patient population consisted of 14 (50.0%) females with a mean age of 70.9±5.4 years. Twenty-eight (100.0%) patients were preoperatively diagnosed with typeⅡ DMR, with a prolapse width of 12.5 (11.0, 16.1) mm, a degree of regurgitation 4+ leading to pulmonary venous reflux, and a New York Heart Association cardiac function class≥Ⅲ. All patients completed the TEER procedure successfully, with immediate postoperative improvement of MR to 0, 1+, and 2+ grade in 2 (7.1%), 21 (75.0%), and 5 (17.9%) patients, respectively. Mitral valve gradient was 2.5 (2.0, 3.0) mm Hg. Deaths, thoracotomy conversion, or device complications such as unileaflet clamping, clip dislodgement, or leaflet injury were negative. Twenty-eight (100.0%) patients completed at least 3-month postoperative follow-up with a median follow-up time of 5.9 (3.6, 6.8) months, during which patients had a mean MR grade of 1.0+ (1.0+, 2.0+) grade and a significant improvement from preoperative values (P<0.001). There was no recurrence of ≥3+ regurgitation, pulmonary venous reflux, reoperation, new-onset mitral stenosis, or major adverse cardiovascular events. Twenty-two (78.6%) patients’ cardiac function improved to classⅠorⅡ. Conclusion The domestic KokaclipTM TEER system has shown excellent preliminary clinical results in selected DMR patients with a high safety profile and significant improvement in MR. Additional large sample volume, prospective, multicenter studies, and long-term follow-up are expected to validate the effectiveness of this system in the future.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content