Objective To investigate the effectiveness of a single threaded anchor fixation under shoulder arthroscopy in the treatment of fresh bony Bankart injury. Methods Between January 2017 and May 2021, 12 patients with fresh bony Bankart injury caused by trauma were treated with a single threaded anchor fixation under shoulder arthroscopy. There were 10 males and 2 females with an average age of 38.8 years (range, 21-64 years). The time between injury and operation ranged from 7 to 30 days (mean, 15.8 days). Preoperative American Shoulder and Elbow Surgeons (ASES) score was 44.9±17.4, the University of California at Los Angeles (UCLA) score was 13.1±5.5; the forward supination, lateral external rotation, and lateral internal rotation of shoulder were (130.8±11.8)°, (25.0±7.9)°, and 9.2±1.6, respectively. CT scan and three-dimensional (3D) reconstruction showed that the fracture fragment area was less than 1/4 of the glenoid area in 10 cases, and 1/4-1/2 in 2 cases. The operation time was recorded. During follow-up, ASES score, UCLA score, Rowes score, and shoulder range of motion were used to evaluate the effectiveness, and shoulder CT scan and 3D reconstruction were used to evaluate the fracture position and healing. Results The operation time ranged from 50 to 150 minutes (mean, 85.5 minutes). All patients were followed up 3-18 months (mean, 9.1 months). There was no serious adverse effect such as infection, re-dislocation, or thrombosis. Three patients had shoulder adhesions after operation. At last follow-up, the forward supination of shoulder [(162.1±30.3)°], lateral external rotation [(37.5±11.2)°], and lateral internal rotation (9.2±1.6) significantly improved when compared with those before operation (t=3.331, P=0.003; t=3.153, P=0.005; t=2.716, P=0.013). The ASES score was 89.7±11.8 and the UCLA score was 32.8±2.4, which significantly increased when compared with those before operation (t=7.368, P<0.001; t=11.370, P<0.001). The Rowes score ranged from 75 to 100 (mean, 92.9). Among them, 9 cases were excellent and 3 cases were good, with an excellent and good rate of 100%. CT re-examination showed that the fracture line disappeared in 11 cases, and the fracture alignment was good; the alignment of the fracture fragment was poor in 1 case whose fracture fragment area was between 1/4 and 1/2 of the glenoid area. Conclusion For the fracture fragment area not exceeding 1/4 of the glenoid, the labrum-capsule complex at the lower end of the bone fragment intact, and the non-comminuted fresh bony Bankart injury, a single threaded anchor fixation under shoulder arthroscopy can achieve better effectiveness, has the advantages of less trauma and faster postoperative recovery.
Objective To investigate the effectiveness of MAKO robotic-arm assisted total hip arthroplasty (THA) via direct anterior approach (DAA) for bony fused hips in ankylosing spondylitis (AS). Methods Between June 2021 and January 2022, MAKO robotic-arm assisted THA via DAA was applied to treat 10 cases (12 hips) of AS with bony fused hips. There were 7 males and 3 females; the age ranged from 30 to 71 years, with an average age of 42.4 years. The duration of AS was 12-35 years, with an average of 21.4 years. The preoperative hip was ankylosed in flexion in 3 cases, with a flexion angle of 20°, 30°, 35°, respectively; 9 cases were ankylosed in extension. The operation time and complications were recorded; the visual analogue scale (VAS) score, Harris score, and Oxford hip scale (OHS) score before and after operation, and postoperative range of motion (flexion, extension, internal rotation, external rotation, adduction, and abduction) were used to evaluate the recovery of joint function; according to the postoperative anteroposterior X-ray film and CT scan of both hip joints, the abduction angle, anteversion angle, the difference between bilateral combined off-set and the lower limb length discrepancy were measured. Results The operation time ranged from 80 to 190 minutes (mean, 134.6 minutes). All 10 patients were followed up 5-11 months (mean, 7.4 months). There was no serious adverse events such as incision infection, deep vein thrombosis of lower extremities, hip redislocation, aseptic loosening of the prosthesis, or death. At 5 months after operation, the acetabular prosthesis angle of abduction was 37°-45° (mean, 40.3°), anteversion angle was 9°-20° (mean, 15.8°). The difference between bilateral combined off-set was 0-10 mm (mean, 4.3 mm); the lower limb length discrepancy was 0-12 mm (mean, 3.5 mm). At last follow-up, the average range of motion of the hip joint was 89.2° in flexion (range, 80°-100°), 1.7° in extension (range, –5°-10°), 7.1° in internal rotation (range, 0°-15°), 20.4° in external rotation (range, 10°-30°), 7.9° in adduction (range, 0°-20°), and 16.5° in abduction (range, 10°-25°). At last follow-up, the VAS score, Harris score, and OHS score significantly improved when compared with those before operation (P<0.05). ConclusionThe MAKO robotic-arm assisted THA via DAA can achieve satisfactory results in the treatment of AS with bony fused hip, which has the advantages of accurate prosthesis installation, soft tissue release, and less trauma during operation.
ObjectiveTo compare the value of CURB-65 score and expanded CURB-65 score in evaluating prognosis of pneumonia in non-HIV infected patient and HIV infected patient.MethodsThe study included 206 hospitalized pneumonia patients without HIV infection and 299 pneumonia patients with HIV infection. According to their clinical prognosis within 4 weeks of treatment, they were divided into a deterioration group and an improvement group. The basic situation and the differences of clinical indicators between the two groups were compared. The predictive value of CURB-65 score and expanded CURB-65 score for clinical prognosis of pneumonia in non-HIV infected patients and HIV infected patients was compared by using receiver operator characteristic (ROC) curve.ResultsFor the pneumonia patients without HIV infection, the area under ROC curve (AUC) of CURB-65 score and expanded CURB-65 score were 0.862 and 0.848, respectively. There was no significant difference in AUC between CURB-65 score and expanded CURB-65 score (Z=0.661, P=0.5084). The Youden indexes of CURB-65 score and expanded CURB-65 score were 60.11% and 54.92%, respectively. For the pneumonia patients with HIV infection, the AUC of CURB-65 score and expanded CURB-65 score were 0.588 and 0.634, respectively. There was no significant difference between them (Z=1.416, P=0.1567). The Youden index of the two scores was 19.53% and 20.52%, respectively.ConclusionsThe CURB-65 score and expanded CURB-65 score can effectively evaluate the clinical prognosis of pneumonia in non-HIV infected patients, but their predicted values are limited in evaluating the prognosis of pneumonia in HIV infected patients.
ObjectiveTo investigate the incidence of perioperative deep venous thrombosis (DVT) of lower extremities and its risk factors in elderly patients with femoral neck fracture. Methods The clinical data of 4 109 elderly patients with femoral neck fracture admitted between August 2012 and November 2020 and met the selection criteria were retrospectively analyzed. Among them, there were 1 137 males and 2 972 females; their ages ranged from 65 to 101 years, with an average of 77.0 years. The time from fracture to admission ranged from 1 to 360 hours, with an average of 35.2 hours. There were 1 858 cases of hemiarthroplasty, 1 617 cases of total hip arthroplasty, and 634 cases of internal fixation surgery. The preoperative age-adjusted Charlson comorbidity index (aCCI) was 4 (3, 5). Perioperative DVT occurred in 857 cases (20.9%). Univariate analysis was performed on age, gender, body mass index, fracture side, time from fracture to admission, operation type, anesthesia type, blood transfusion, blood pressure after admission, and preoperative aCCI in patients with and without perioperative DVT, and logistic regression analysis was used to screen the risk factors of perioperative DVT in elderly patients with femoral neck fracture. ResultsUnivariate analysis showed that there were significant differences in age, gender, time from fracture to admission, operation type, and preoperative aCCI between the two groups (P<0.05). Further logistic regression analysis showed that age>75 years, female patients, time from fracture to admission>24 hours, and preoperative aCCI>5 were risk factors for perioperative DVT (P<0.05). Conclusion Elderly patients with femoral neck fracture have a higher incidence of perioperative DVT. The advanced aged and female patients, patients with longer fracture time and more comorbidities need to pay special attention to the prevention of perioperative DVT to minimize the occurrence of DVT during femoral neck fractures.
ObjectiveTo investigate the feasibility and effectiveness of “tail compression fixation+suture bridge” technology under shoulder arthroscopy for treating primary tear in medial enthesis of rotator cuff. Methods The clinical data of 11 patients with primary tear in medial enthesis of rotator cuff who met the selection criteria between October 2020 and October 2022 were retrospectively analyzed, including 3 males and 8 females, aged 39-79 years, with an average of 61.0 years. Rotator cuff injury was caused by traumatic fall in 8 cases, and the time from injury to admission was 1-4 months, with an average of 2.0 months; the remaining 3 cases had no obvious inducement. The active range of motion of the affected shoulder was limited, with an active forward flexion range of motion of (64.1±10.9)°, abduction of (78.1±6.4)°, internal rotation of (48.2±6.6)°, and external rotation of (41.8±10.5)°; 5 cases had shoulder stiffness. The preoperative visual analogue scale (VAS) score was 7.8±0.8 and the American Society of Shoulder and Elbow Surgeons (ASES) score was 23.9±6.4. The patients were treated with “tail compression fixation+suture bridge” technology under shoulder arthroscopy, and the pain and functional recovery were evaluated by VAS score, ASES score, and active range of motion of shoulder joint at last follow-up; MRI was performed after operation, and the integrity of rotator cuff was evaluated by Sugaya classification system. Results All the 11 patients were followed up 2-22 months, with an average of 13.5 months. All incisions healed by first intention, and there was no complication such as infection, rotator cuff re-tear, and anchor falling off. At last follow-up, the VAS score was 0.8±0.7 and the ASES score was 93.5±4.2, which significantly improved when compared with those before operation (P<0.05). All 11 patients had no significant swelling in the shoulders, and the active range of motion was (165.1±8.8)° in flexion, (75.3±8.4)° in abduction, (56.6±5.5)° in internal rotation, and (51.8±4.0)° in external rotation, which significantly improved when compared with those before operation (P<0.05). Shoulder MRI showed adequate tendon thickness and good continuity in 9 cases, including 4 cases with partial high signal area; and 2 cases with inadequate tendon thickness but high continuity and partial high signal area. According to Sugaya classification system, there were 4 cases of type 1 (36.4%), 5 cases of type 2 (45.5%), and 2 cases of type 3 (18.1%).Conclusion For the patients with primary tear in medial enthesis of rotator cuff, the “tail compression fixation+suture bridge” technology under shoulder arthroscopy is simple and effective.