ObjectiveTo explore the clinical features of atypical bronchial asthma with chief complaint of palpitations. MethodsTwelve cases with unexplained palpitations diagnosed by asthma were analyzed retrospectively. ResultsThe patients were diagnosed with asthma through bronchodilation test,skin prick tests,fractional exhaled nitric oxide (FeNO) and diagnostic treatment.The ratio of male to female cases was 1:5. The ventilation lung function of all patients was in normal range. The median time of misdiagnosis was 13.5(3-120) months. 41.6% of cases had dust mite positive skin prick test. The median value of FeNO was 32.75(18-54) ppb. The symptoms of all patients were relieved completely after standard treatment. ConclusionPalpatation may be a specific presentation of asthma characterized with eosinophilic airway inflammation which may be misdiagnosed as other diseases for a long time,especially in elder women. To improve the knowledge of this kind of atypical asthma,detailed medical history, experimental examinations and diagnostic treatment response are important to confirm the diagnosis in time.
ObjectiveTo explore the predictive value of fractional exhaled nitric oxide (FeNO) in the treatment response of adult asthmatic patients. Methods64 adult outpatients with asthma from Peking Union Hospital between March and September 2013 were recruited in the study. All patients completed asthma control test (ACT) together with exhaled nitric oxide (FeNO) and pulmonary function test. Then the patients were classified into a higher FeNO group (n=33) and a normal FeNO group (n=31) according to FeNO level. All patients accepted regular inhaled ICS/LABA treatment (salmeterol and fluticasone 50/250). Three months later all patients reaccepted ACT,FeNO and pulmonary function test. ResultsThe ACT score increased in all patients,and was significantly higher in the higher FeNO group than that in the normal FeNO group[22.07±5.49 vs. 19.23±5.48,t=2.893,P<0.05]. The complete control rate of the higher FeNO group was higher than that in the normal FeNO group (42.42% vs. 19.35%,χ2=3.960,P<0.05). The FEV1 and FEV1%pred of two groups both increased significantly (P<0.05),but there was no significant difference between two groups (P>0.05). Correlation analysis showed that FeNO and the declined rate of FeNO was negatively correlated with the ACT score(r=-0.302,P<0.05;r=0.674,P<0.01) and positively correlated with the improvement of ACT score (r=0.514,P<0.01;r=0.674,P<0.01). No significant correlation was found between FeNO and FEV1 or FEV1%pred. ConclusionThe effect of ICS/LABA therapy is better for asthma patients with higher FeNO. FeNO can be used for predicting the response to ICS/LABA therapy in patients with asthma and guiding the treatment.
Objective Chronic obstructive pulmonary disease( COPD) is highly heterogeneous. In theory, the patients with same clinical manifestations, treatment response and prognosis can be classified into one phenotype, which may have same biological or physiological mechanisms. In this study the profiles of patients with COPD including body mass index( BMI) , Goddard score, fractional exhaled nitric oxide( FeNO) were analyzed in order to find some special phenotypes.Methods Patients with COPD at stable stage in Ruijin Hospital from May 2011 to February 2012 were evaluated with COPD assessment test ( CAT) in Chinese version, St. George’s Respiratory Questionnaire( SGRQ) , hospital anxiety and depression( HAD) rating scale, pulmonary function test, and 6-minute walking test ( 6MWT) . Baseline data was collected including height, weight, drug use, times of exacerbation, etc. Results A total of 126 patients were recruited. The patients with low BMI had poorer quality of life, lower FEV1 , poorer diffusion function, and higher Goddard score, and was easier to develop anxiety and depression. The patients with high BMI had lower oxygen saturation at rest. We failed to define a certain kind of phenotype according to FeNO. The patients of emphysema phenotype( assessed by Goddard score) had lower BMI, decreased lung diffusion capacity, and poorer quality of life. Conclusion The study can define COPD patients into some special phenotypes( low BMI and emphysema phenotype) , but failed to define a certain kind of phenotype according to FeNO.
Objective To compare the value of fractional exhaled nitric oxide ( FENO) measurement and leukotriene D4 bronchial provocation test ( LTD4-BPT) in diagnosis and evaluation of asthma. Methods 20 uncontrolled,22 partially controlled, 20 controlled asthmatics, and 21 normal subjects were enrolled in the study. Measurement of FENO was performed followed by LTD4-BPT. The distribution characteristics and relationship of both results were analyzed, and the diagnostic value was compared using receiver operation characteristic ( ROC) curve.Results FENO was above 25. 0ppb in 80. 7% of the asthmatics. The proportion of asthmatics with FENO between 26.0ppb and 49.0ppb was larger in the uncontrolled and partially controlled subjects than that in the controlled subjects. Both the median and interquartile range of cumulative dosage ( PD20FEV1-LTD4) were much higher in the controlled asthmatics as compared with the uncontrolled and partially controlled asthmatics. The area under the ROC curve ( AUC) for PD20FEV1-LTD4 [ AUC: 0.914, 95% CI: ( 0.855, 0.974) ] was larger than that of FENO [ AUC: 0.820, 95% CI: ( 0.718, 0.921) ] . Higher sensitivity ( 0.8570 vs. 0.8065) and specificity ( 0.9048 vs. 0.7619) were in favor of PD20 FEV1 -LTD4 ≤ 4.800 nmol as compared with FENO ≥ 26.0ppb being the positive threshold. Conclusion Compared with FENO measurement, LTD4-BPT has higher sensitivity and specificity and is of higher diagnostic value for asthma.
Objective To investigate the clinical characteristics of allergic and non-allergic asthma in Chinese adult asthmatic patients. Methods Consecutive treatment-naive adult outpatients with asthma were retrospectively analyzed in West China Hospital, Sichuan University from October 2014 to June 2016. The patients were classified into a non-allergic asthma (NAAS) group and an allergic asthma (AAS) group by skin prick test or antigen-specific IgE test. The differences between allergic and non-allergic asthma were compared in respect of gender, age, asthma control test (ACT) score, lung function, fractional exhaled nitric oxide (FeNO) level, body mass index (BMI), disease severity,etc. Results A total of 131 patients were enrolled in which 72 cases (54.96%) were allergic asthmatics and 59 cases (45.04%) were non-allergic asthmatics. The level of FeNO was statistically different (t=–2.762,P=0.007) between the NAAS group and the AAS group [(51.1±32.6)ppbvs. (69.1±41.7)ppb]. Seventeen cases of the NAAS group and 48 cases of the AAS group were complicated with rhinitis with statistically significant difference (χ2 =19.396,P=0.000). Airway limitation reversibility test showed that there were 37 cases in AAS and 20 cases in NAAS with no airway obstruction (NAO), 26 cases in AAS and 22 cases in NAAS with reversible airflow obstruction (RAO), 9 cases in AAS and 17 cases in NAAS with irreversible airflow obstruction (IAO), respectively, with statistically significant difference between two groups (Z=–2.461,P=0.014). There were 20 cases (33.9%) in NAAS and 37 cases (51.4%) in AAS with mild intermittent or persistent asthma, 18 cases (30.5%) in NAAS and 19 cases (26.4%) in AAS with moderate persistent asthma, 21 cases (35.6%) in NAAS and 16 (22.2%) in AAS with severe persistent asthma, respectively, with statistically significant difference (Z=–2.115,P=–0.034). The age, ACT score, FEV1%pred, and BMI had no statistical difference between two groups (allP>0.05). Conclusion Compared with allergic asthma, non-allergic asthma has less rhinitis, lower FeNO levels and higher prevalence of irreversible airflow obstruction.
ObjectiveTo evaluates the values of fractional exhaled nitric oxide (FENO) in the treatment of chronic cough prospectively.MethodsSubjects with chronic cough were recruited from the outpatient clinic of China-Japan Friendship Hospital. All the patients accepted FENO tests, sputum cell counts, pulmonary function tests, bronchial provocation tests, serum IgE, cough symptom scores and Leicester Cough Questionnaire before and after treatment of 4 weeks.ResultsThere were 29 patients with cough variant asthma (CVA), 19 patients with eosinophilic bronchitis (EB) and 39 patients with other causes. The baseline FENO level of the subjects whose coughs were relieved after inhaled corticosteroids (ICS) therapy of 4 weeks was (63±42) ppb, significantly higher than those with bad-response [(28±13) ppb, P<0.01]. The proportion of FENO decrease after ICS therapy was not only significantly related to the proportion of eosinophilic decrease (r=0.54, P<0.01), but also significantly related to the proportion of decrease of cough symptom scores (r=0.48, P<0.01). To distinguish the good responders from bad responders, the optimal baseline FENO cutoff value was 36 ppb, with sensitivity of 82%, specificity of 93%, positive predictive value of 94%, negative predictive value of 87%, accuracy of 83%.ConclusionsThere is a good relationship between the FENO decreasing levels after ICS therapy and the reliefs of cough symptoms in the CVA and EB patients. Chronic cough patients with FENO value more than 36 ppb are indicated to respond to ICS therapy.
ObjectiveThrough measuring fractional exhaled nitric oxide (FeNO) and eosinophil levels of peripheral blood in chronic obstructive pulmonary disease (COPD) patients with different phenotype of acute exacerbation frequency, to predict the therapeutic effect of glucocorticoid therapy and guide the clinical treatment of different subtypes patients with acute exacerbations of COPD.MethodsA total of 127 patients with acute exacerbation of COPD in Suining Central Hospital from February 2017 to October 2019 were recruited. They were divided four groups according to the number of acute exacerbations in the past one year and the treatment scheme, ie. a frequent acute exacerbation with glucocorticoid treatment group (34 cases), a frequent acute exacerbation with non-glucocorticoid treatment group (31 cases), a non-frequent acute exacerbation with glucocorticoid treatment group (30 cases), and a non-frequent acute exacerbation with non-glucocorticoid treatment group (32 cases). FeNO value, eosinophil ratio in peripheral blood, COPD assessment test (CAT) score, and interleukin-8 (IL-8) concentration were measured before and on the 10th day of treatment, and the differences within group and between groups before and after treatment were compared.ResultsCAT score, FeNO, eosinophil ratio and IL-8 level in the four groups were significantly improved on the 10th day after treatment (all P<0.05). The declines of FeNO value, eosinophil ratio, and IL-8 level on the 10th day of treatment compared with those before treatment in the frequent acute exacerbation with glucocorticoid treatment group and the frequent acute exacerbations with non-glucocorticoid treatment group were larger than those in the non-frequent acute exacerbation with glucocorticoid treatment group and the non-frequent acute exacerbation with non-glucocorticoid treatment group (all P<0.05). The declines of FeNO value, blood eosinophil ratio and IL-8 level in the frequent acute exacerbation with glucocorticoid treatment group were also statistically significantly larger than those in the frequent acute exacerbations with non-glucocorticoid treatment group (all P<0.05). The improvement of CAT score in the frequent acute exacerbation with glucocorticoid treatment group was greater than that in other three groups (all P<0.05). There was no significant difference in CAT score between the non-frequent acute exacerbation with glucocorticoid treatment group and the non-frequent acute exacerbation with non-glucocorticoid treatment group (P>0.05).ConclusionsThe degree of airway inflammation is more obvious in patients with frequent acute exacerbation phenotype of COPD. FeNO value can reflect the level of airway inflammation in patients with frequent acute exacerbation of COPD and evaluate the response to glucocorticoid therapy.
ObjectiveTo explore the diagnostic value of fractional exhaled nitric oxide (FeNO) in adult asthma.MethodsPubMed, Embase, Cochrane Library, Wanfang, CNKI and VIP databases were searched for relevant literatures from the time of database establishment to February 2021. Data analysis were made by Revman and Stata.ResultsA total of 44 articles with 47 records and 9654 subjects were included. The diagnosis sensitivity, specificity, positive and negative predictive value of FeNO were 0.71 (95%CI 0.65 - 0.76), 0.80 (95%CI 0.75 - 0.84), 3.47 (95%CI 2.86 - 4.21), and 0.37 (95%CI 0.31 - 0.43), respectively. The diagnostic odds ratio was 9.49 (95%CI 7.13 - 12.61), and the area under the receiver operating characteristic curve was 0.82 (95%CI 0.79 - 0.85).ConclusionsFeNO has certain diagnostic value in diagnosis of asthma. Types of asthma, region and cut-off value all have impact on the diagnostic efficiency of FeNO.