west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "GE Junbo" 13 results
  • The current situation of transcatheter aortic valve replacement in China 2017

    Transcatheter aortic valve replacement (TAVR) as a mature technology has been widely applied in Western countries. In China, with the first two domestic prostheses being approved for commercial use, the technology now is expecting a fast development. In this article, we reviewed the features of Chinese aortic stenosis patients, the early Chinese experience of TAVR, the application of domestic prostheses and remaining problems.

    Release date:2018-02-26 05:32 Export PDF Favorites Scan
  • Development of transcatheter heart valve therapy in the world in 2020

    In 2020, due to the impact of the novel coronavirus epidemic, the development of transcatheter heart valve therapy has been shown to slow down, but there are still many aspects worth noting. The indication of monoclonal antibody after transcatheter aortic valve replacement (TAVR) should be further clarified. Low surgical risk patients were included in TAVR relative indications. Mitraclip G4 was approved by CE. The indication of atrial septal occlusion after mitraclip should be further clarified. The technique of coaptation augmentation is expected to become a new method of mitral valve interventional repair. Tendyne transcatheter mitral valve was approved by European Union. Transcatheter tricuspid valve treatment equipments, TriClip and PASCAL obtained CE mark. TAVR technology is being popularized rapidly in China, and what’s more, balloon dilated valve Sapien 3 and new recyclable repositioning valve system-Venus plus have entered the domestic market. A number of mitral valve therapeutic instruments have appeared one after another, and China's first tricuspid valve lux has completed its FIM research. Finally, with the improvement of devices and technology in the future, interventional therapy of heart valve is expected to benefit more patients.

    Release date:2021-04-25 09:57 Export PDF Favorites Scan
  • Estimation of the number of patients with mitral regurgitation in China

    Mitral regurgitation (MR) is the most common heart valve disease. In recent years, the rise of interventional therapy has expanded the indications of interventional treatment for patients with MR, but the epidemiological characteristics of MR (especially the number of patients with MR requiring treatment) in China are still unclear. In this paper, we analyzed and estimated the number of MR patients in China based on three epidemiological studies in Europe and America, and referring to the patients population surveys from Zhongshan Hospital Affiliated to Fudan University, the Second Affiliated Hospital Zhejiang University School of Medicine and Beijing Fuwai Hospital. Our analysis estimated that about 7.5 million patients with MR need intervention in China, including about 5.5 million patients with severe MR.

    Release date:2021-06-07 02:03 Export PDF Favorites Scan
  • Transcatheter edge-to-edge repair (TEER): Past, current and future perspectives

    Transcatheter edge-to-edge repair (TEER) originated from surgical edge-to-edge repair. MitraClip is the first mature TEER device, and the TEER based on MitraClip is far ahead of many transcatheter mitral valve repair (TMVr) technologies in terms of safety, effectiveness and popularity, so it is named separately in the latest guidelines. The TEER has the following advantages: consistent with basic medical principles, few implants, precise target, less invasive and repeatable. However, there are also some shortcomings, such as the relatively complex design of transfemoral device, target single and relatively narrow indications. At present, the main clinical data of TEER are mainly from the clinical practice of MitraClip. Based on the three-year outcomes of COAPT study, both 2020 ACC/AHA guideline and 2020 ACC expert consensus decision pathway on the management of mitral regurgitation recommend in patients with chronic heart failure with left ventricular dysfunction and severe mitral regurgitation in nonresponders to medicine treatment. Edward's PASCAL, another TEER device, has two models. Among the domestic TEER devices, the ValveClamp of Hanyu medical technology has many distinct advantages, such as simple operation, large clamping area, high clamping efficiency and no need of X-ray. DragonFly, another domestic TEER device, has also completed its feasibility study. There are five trends of TEER in the future: further expansion of indications, combination with other interventional techniques, repeatable operations, transcatheter mitral valve replacement after TEER, and continuous improvement and innovation of equipment.

    Release date: Export PDF Favorites Scan
  • Transcatheter edge-to-edge repair: Operating theories, basic principles, and predictors of prognosis

    Mitral regurgitation is one of the most common heart valve diseases. Transcatheter edge-to-edge repair (TEER) is currently the most developed and commonly used interventional technique for mitral regurgitation and is recommended by the latest European and American guidelines for patients who are at high surgical risk. TEER device usually consists of a clamping device and a delivery system. The trajectory of the clamping device is called the trajectory, and the trajectory can be well established with the five dimensions movement of the delivery system: left-right oscillation, anterior-posterior oscillation, overall parallel movement, the clamping device's own clockwise rotation, and vertical up-and-down movement. The delivery system's anteroposterior and lateral oscillations are concentrated on the virtual puncture site. Furthermore, the location of the septal puncture site has a significant impact on the establishemnt of the trajectory. The evulation of three variables and adherence to the "4M principles" are necessary for the successful TEER. The three variables are: the position of the clip in the center of the regurgitation,the arm orientation of the clip perpendicular to the boundary of anterior and posterior leaflets, as well as the appropriate length of clamping. The "4M principles" include favorable valve morphology, residual mitral regurgitation below grade 2+, mean transvalvular pressure≤5 mm Hg, and an appropriate amount of leaflets clamping. Patients' baseline situation, the degree of mitral regurgitation and ventricular remodeling, as well as the valve morphology and the outcome of the procedure, are the factors determining the prognosis of patients after TEER.

    Release date: Export PDF Favorites Scan
  • Mitral transcatheter edge-to-edge repair: A state of art and strategic principles

    Transcatheter edge-to-edge repair (TEER) for mitral regurgitation (MR) is known as M-TEER. Its strengths include: precise targets and fewer implants; simple and clear principles for catheterization; originating from dependable medical concepts and broad applicability. Furthermore, TEER offers advantages in real-time hemodynamic and effectiveness measurement throughout the procedure over surgical edge-to-edge repair (SEER). When it comes to patients with degenerative mitral regurgitation , M-TEER should aim to deliver more optimum procedural outcomes. In functional mitral regurgitation, a modest transvalvular gradients or moderate residual shunt can be tolerated with M-TEER, which reduces the risk of problems and has no bearing on the patient's prognosis.

    Release date: Export PDF Favorites Scan
  • New understanding of the mechanism of mitral regurgitation: From a two-dimensional point to a four-dimensional space-time

    Mitral regurgitation (MR) is a kind of valvular heart disease with a complicated pathogenesis. However, the current clinical understanding of MR mostly stays in a purely spatial perspective. We suggest that the evaluation of MR should break through the limited thinking of the area of a two-dimensional single frame, and transfer to a comprehensive evaluation of three-dimensional space-time integration (i.e. four-dimensional space-time). Secondly, it is of significance to pay attention to the time mechanism and time thinking of the occurrence of MR. The amount of MR may be different in different cardiac cycles or within the same cardiac cycle. Finally, changes in the time dimension of cardiac contraction can lead to the occurrence of MR and sometimes it is necessary to understand MR from time thinking rather than spatial thinking.

    Release date: Export PDF Favorites Scan
  • Investigation and analysis of operations, intraoperative instruments and nursing status of transcatheter aortic valve replacement in China

    ObjectiveTo investigate the operation of transcatheter aortic valve replacement (TAVR), the use of TAVR instruments and the current situation of TAVR-related nursing in our country, to reveal the characteristics of TAVR in various hospitals in our country, and to provide reference data for improving perioperative nursing and industry development of TAVR. MethodsA questionnaire survey was conducted among the head nurses of the cardiac catheterization laboratories of 51 hospitals in China that carried out TAVR operations, with a total of 5 items and 23 questions. The current situation of TAVR operation methods, intraoperative instruments and nursing care in China were analyzed. ResultsThe number of hospitals in China which started conducting TAVR and the beginning year were: 2 in 2010, 1 in 2012, 1 in 2013, 1 in 2015, 11 in 2016, 13 in 2017, 15 in 2018 and 7 in 2019; the number of transfemoral TAVR in 2019: 32 (62.75%) hospitals conducted on less than 20 patients, 7 (13.73%) hospitals 20-<50 patients, 6 (11.76%) hospitals 50-100 patients and 6 (11.76%) hospitals more than 100 patients; TAVR strategies adopted by most hospitals were: general anesthesia (90.20%), the use of vascular sealers (80.39%), backing by cardiac surgeon (74.51%) and using homemade prosthetic valves. Conclusion At present, the number of TAVR carried out in Chinese hospitals is still far behind that of developed countries in Europe and the United States. Our country has adopted the form of multidisciplinary cardiac team cooperation and formed a TAVR nursing model with Chinese characteristics.

    Release date: Export PDF Favorites Scan
  • Hemocompatibility of bioprosthetic heart valve materials respectively based on glutaraldehyde and non-glutaraldehyde treatment

    ObjectiveTo study the hemocompatibility of bioprosthetic heart valve materials respectively based on glutaraldehyde and non-glutaraldehyde treatment. MethodsFresh bovine pericardium was treated with glutaraldehyde or non-glutaraldehyde after adipose tissue was removed. To evaluate the hemocompatibility of the two bioprosthetic heart valve materials, hemolysis test, in vitro fibrinogen adsorption experiment, platelet adhesion experiment, thrombin-antithrombin complex (TAT) test, complement activation assay and ex vivo circulation experiment were performed. ResultsThe hemolysis test results demonstrated that both of the materials showed hemolytic rates lower than 5%. The results of TAT test and complement activation assay showed no statistical differences among the two materials and the blank control group. Compared to the bioprosthetic heart valve materials with glutaraldehyde-based treatment, the materials with non-glutaraldehyde-based treatment showed significantly decreased fibrinogen adsorption, platelet adhesion and thrombosis. ConclusionCompared to the bioprosthetic heart valve materials with glutaraldehyde-based treatment, the materials with non-glutaraldehyde-based treatment show better hemocompatibility.

    Release date: Export PDF Favorites Scan
  • Transcatheter aortic valve replacement (TAVR) annual report 2023

    Transcatheter aortic valve replacement (TAVR) has seen a surge in clinical research, basic research, and innovative device development both domestically and internationally in the previous 2023. This article aims to review the progress of TAVR in the past year from the perspectives of international, and domestic research development of application. It highlights new clinical and basic research findings both domestically and internationally, the emergence of new devices and technologies, and the development and use of TAVR in China. Finally, it provides an outlook on the trajectory of TAVR development in 2024.

    Release date: Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content