west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "GUO Haijiang" 7 results
  • Transcatheter valve-in-valve implantation using the J-Valve for bioprosthetic degeneration at different anatomic positions: A single-center experience

    Objective To summarize the early results and clinical experience of using the J-Valve for transcatheter valve-in-valve implantation in patients with degenerated bioprosthesis at different anatomic positions. Methods A retrospective analysis was conducted to evaluate the short-term outcomes of 39 consecutive patients who underwent transcatheter valve-in-valve implantation using the J-Valve System in the Department of Cardiac Surgery of Guangdong Provincial People’s Hospital from April 2020 to August 2021 due to bioprosthetic degeneration at different anatomic positions. Among them, 35 patients underwent transcatheter mitral valve-in-valve (TMViV) implantation, 1 transcatheter aortic valve-in-valve (TAViV) implantation, 1 transcatheter tricuspid valve-in-valve (TTViV) implantation, 1 TMViV implantation with simultaneous TAViV implantation, and another one TMViV implantation with simultaneous transcatheter aortic valve replacement (TAVR) and perivalvular leakage (PVL) closure. Results Among the 35 patients who underwent isolated TMViV implantation, 17 were male and 18 were female with a mean age of 72.6±10.8 years. Mean duration between two operations was 10.5±2.7 years. The mean Society of Thoracic Surgeons and EuroSCORE Ⅱ scores were 12.95%±9.61% and 13.91%±8.94%, respectively. The device success rate was 97.1% and no death occured during the operation. One patient was transferred to thoracotomy due to device displacement, 1 was re-opened for uncontrolled bleeding, and 1 presented left ventricular outflow tract obstruction. One patient underwent craniotomy due to intracranial hemorrhage within 30 days after surgery, and no other complications occurred including death, stroke, permanent pacemaker implantation, cardiac tamponade, or re-hospitalization. The mean follow-up time was 6.0±4.4 months, the mean mitral valve gradient was significantly improved (10.4±2.0 mm Hg vs. 5.5±1.2 mm Hg, P<0.05), and the New York Heart Association class≤Ⅱ in all the patients at the last follow-up. Among the other 4 patients who did not undergo isolated TMViV implantation, the transapical TAViV implantation and the trans-right atrium TTViV implantation were successful without intra- or post-operative complications. The patient who underwent TMViV and TAViV implantation simultaneously via transapical approach died of severe pulmonary hemorrhage and multiple organ failure 16 days after surgery. The other patient who underwent transapical TMViV combined with TAVR and PVL closure died of septic shock 10 days after the surgery. Conclusion Transcatheter valve-in-valve implantation using the J-Valve system is shown to be a safe and effective procedure to treat mitral, aortic and tricuspid bioprosthetic valve dysfunction in high-risk patients, providing a new alternative to surgical surgery for degenerated bioprosthesis at different anatomic positions. However, simultaneous different valves intervention should be very cautious.

    Release date: Export PDF Favorites Scan
  • Clinical efficacy of reimplantation of anomalous origin of the left coronary artery from the pulmonary artery: A case control study

    Objective To analyze the clinical efficacy and mid-term outcomes of reimplantation of anomalous origin of left coronary artery from the pulmonary artery (ALCAPA), and to evaluate whether concomitant management of mitral regurgitation (MR) during ALCAPA repair is needed. Methods Between March 2005 and March 2015, 52 consecutive patients (20 males and 32 females with a median age of 10 months ranging 2-193 months) underwent reimplantation of ALCAPA at Department of Cardiac Surgery, Guangdong Cardiovascular Institute. There were 14 males and 21 females with a mean age of 35.4±42.8 months not receiving mitral valvuloplasty (a Non-MVP group), and 6 males and 11 females with a mean age of 13.5±11.0 months receiving mitral valvuloplasty (a MVP group). In order to facilitate the analysis, degree of MR was graded by number: 0.0=none, 1.0=trivial, 2.0=mild, 2.5=mild-moderate, 3.0=moderate, 3.5=moderate-severe and 4.0=severe. Results The left ventricular fractional shortening (LVFS) and left ventricular end diastolic diameter (LVEDD) demonstrated significant improvement between preoperation and discharge (28.6%±9.6% vs. 32.1%±10.1%, P=0.023; 38.4±5.6 mm vs. 30.5±5.7 mm, P<0.001), and there was also significant improvement in the mean MR grade between preoperation and discharge (2.9±1.2,vs. 2.4±1.2, P=0.001). There were 4 in-hospital deaths (7.7%). The median follow-up was 21.0 months (ranging 1.5-111.0 months). Three patients (5.8%) were lost to follow-up, 1 patient required reoperation for mitral valve replacement and there was no death during follow-up. Significant improvement was seen in LVFS between discharge and final follow-up (32.1%±10.1% vs. 38.0%±6.0%, P=0.001); however, there was no significant difference in the degree of MR between discharge and final follow-up (2.4±1.2 vs. 2.3±1.2, P=0.541). There was no significant difference in cardiopulmonary bypass time, aortic cross-clamping time, mechanical ventilation time or hospital stay between the two groups. Conclusion Creation of a dual coronary system with reimplantation of the left coronary artery results in complete recovery of left ventricular function. However, concomitant management of MR during ALCAPA repair remains controversial. Concomitant mitral valve repair for ALCAPA patients with moderate-severe and severe MR is helpful to early function recovery of mitral valve.

    Release date:2018-03-05 03:32 Export PDF Favorites Scan
  • Association of long frozen elephant trunk and incidence of spinal cord injury in patients with acute type A aortic dissection: A single center retrospective cohort study

    ObjectiveTo evaluate whether long frozen elephant trunk (FET) increases the risk of spinal cord injury in patients with acute type A aortic dissection.MethodsFrom 2018 to 2019, 172 patients with acute type A aortic dissection were treated in Guangdong Provincial People’s Hospital. They were divided into two groups according to the length of FET: patients treated with stents of 100 mm in length were enrolled into a short FET group, and those with stents of 150 mm in length into a long FET group. There were 124 patients in the short FET group, including 108 (87.1%) males and 16 (12.9%) females with a mean age of 51.8±7.9 years. There were 48 patients in the long FET group, including 44 (91.7%) males and 4 (8.3%) females with a mean age of 50.6±9.7 years. The clinical data and prognosis of the patients were analyzed.ResultsThe mean distal stent graft was at the level of T 8.5±0.7 in the long FET group, and at the level of T 6.8±0.6 in the short FET group (P=0.001). Sixteen patients died after operation in the two groups, including 13 (10.5%) in the short FET group and 3 (6.2%) in the long FET group (P=0.561). There were 7 patients of spinal cord injury in the two groups, including 6 (4.8%) in the short FET group and 1 (2.2%) in the long FET group (P=0.675). There was no statistical difference in other complications between the two groups. The follow-up time was 16.7 (1-30) months. During the follow-up, 2 patients died in the long FET group and 5 died in the short FET group. No new spinal cord injury or distal reintervention occurred during the follow-up.ConclusionLong FET does not increase the incidence of spinal cord injury in patients with acute type A aortic dissection.

    Release date: Export PDF Favorites Scan
  • The value of right atrial myocardial fibrosis in evaluating the prognosis of isolated tricuspid valve surgery after left heart valve surgery

    ObjectiveTo investigate the predictive value of right atrial myocardial fibrosis in the prognosis of isolated tricuspid regurgitation surgery after left heart valve surgery. MethodsThe patients who underwent tricuspid valvuloplasty by the same operator in Guangdong Provincial People's Hospital from April 2016 to August 2021 due to long-term isolated severe tricuspid regurgitation after left heart valve surgery were included in the study. According to the degree of right atrial myocardial fibrosis, the patients were divided into three groups: a mild group, a moderate group, and a severe group. The clinical data of these patients were compared and analyzed. ResultsA total of 75 patients were enrolled, including 16 males and 59 females with an average age of 57.0±8.4 years. There were 30 patients in the mild group, 29 patients in the moderate group and 16 patients in the severe group. In terms of the preoperative data, there were statistical differences in cardiac function grade, right atrial diameter, tricuspid incompetence area among the three groups (P<0.05). In terms of the postoperative data, there were statistical differences among the three groups in the cardiopulmonary bypass time, mechanical ventilation time, ICU monitoring time, complication rate and mortality (P<0.05). Further pairwise comparison showed that, compared with the mild group, the severe group had longer mechanical ventilation time (P=0.024), longer ICU monitoring time (P=0.003) and higher incidence of postoperative complications (P=0.024), while the moderate group had no statistical difference in all aspects (P>0.05); compared with the moderate group, the severe group had longer ICU monitoring time (P=0.021) and higher incidence of complications (P=0.006). ConclusionThe early outcome of tricuspid valvuloplasty in patients with isolated tricuspid regurgitation after left heart valve surgery with severe right atrial myocardial fibrosis is worse than that in the patients with mild and moderate fibrosis, suggesting that the degree of myocardial fibrosis in the right atrium can be a predictor of the effect of tricuspid regurgitation surgery and a judgement indicator of the surgery timing.

    Release date: Export PDF Favorites Scan
  • Preliminary clinical outcomes of the domestic Renatus® balloon-expandable valve system for the treatment of severe aortic stenosis: A prospective cohort study

    Objective To evaluate the early clinical outcomes of the Renatus® balloon-expandable valve in the treatment of severe aortic stenosis. MethodsFrom November 2021 to April 2022, a total of 38 patients who received Renatus® balloon-expandable valve for severe aortic stenosis in Guangdong Provincial People's Hospital were included. There were 22 males and 16 females, with an average age of 73.7±5.3 years. Mean aortic gradient and peak aortic jet velocity at baseline, post-procedure, and follow-up were compared. Clinical outcomes including all-cause mortality, perivalvular leakage, serious adverse cardiovascular events and the occurrence of permanent pacemaker implantation were assessed. ResultsAll patients completed the procedure successfully without conversion to thoracotomy or perioperative death. The post-implant mean aortic pressure gradient was decreased from 41.5 (27.8, 58.8) mm Hg to 6.0 (3.0, 8.0) mm Hg, and the peak aortic jet velocity was also decreased from 4.1±0.9 m/s to 1.7±0.4 m/s (P<0.001). Pacemakers were required in 2 (5.3%) patients. The median follow-up time was 27.5 (23.0, 87.5) d, with a follow-up rate of 100.0%. The mean aortic gradient was 8.0 (7.0, 10.8) mm Hg and peak aortic jet velocity was 2.0±0.3 m/s, showing significant improvement compared with those in the preoperative period (P<0.001). No severe aortic regurgitation or paravalvular leak was observed. There was no serious cardiovascular adverse event or reoperative event during the study period. ConclusionTranscatheter aortic valve replacement with the domestic Renatus® balloon-expandable valve system is a safe and effective procedure for selected patients with severe aortic stenosis who are at high risk or not candidates for surgical aortic valve replacement.

    Release date: Export PDF Favorites Scan
  • Pulsed field surgical ablation treatment for atrial fibrillation: The first case report

    Atrial fibrillation is a common clinical arrhythmia with a high incidence. The main clinical treatment methods for atrial fibrillation at present include radiofrequency catheter ablation and cryoablation. In recent years, pulsed field ablation, a new energy source with tissue specificity, is gradually being used in clinical practice. This article presents the world's first case of atrial fibrillation treated with pulsed field surgical ablation, in which the patient underwent surgical intervention of the valves and coronary arteries at the same time and recovered to sinus rhythm intraoperatively. 24 hour-Holter electrocardiogram after 1 month and 3 months showed no atrial fibrillation. The patient’s symptoms, cardiac function, and quality of life improved significantly.

    Release date: Export PDF Favorites Scan
  • Early clinical outcomes of the domestic KokaclipTM transcatheter edge-to-edge mitral valve repair system for severe degenerative mitral regurgitation: A single-arm, prospective, single-group target value clinical trial

    Objective To summarize and analyze the preliminary clinical outcomes of the KokaclipTM transcatheter edge-to-edge mitral valve repair system for severe degenerative mitral regurgitation (DMR). Methods This study was a single-arm, prospective, single-group target value clinical trial that enrolled patients who underwent the KokaclipTM transcatheter edge-to-edge repair (TEER) system for DMR in the Department of Heart Surgery of Guangdong Provincial People's Hospital, Guangdong Cardiovascular Institute from June 2022 to January 2023. Differences in the grade of mitral regurgitation (MR) during the perioperative and follow-up periods were compared, and the incidences of adverse events such as all-cause death, thoracotomy conversion, reoperation, and severe recurrence of MR during the study period were investigated. Results The enrolled patient population consisted of 14 (50.0%) females with a mean age of 70.9±5.4 years. Twenty-eight (100.0%) patients were preoperatively diagnosed with typeⅡ DMR, with a prolapse width of 12.5 (11.0, 16.1) mm, a degree of regurgitation 4+ leading to pulmonary venous reflux, and a New York Heart Association cardiac function class≥Ⅲ. All patients completed the TEER procedure successfully, with immediate postoperative improvement of MR to 0, 1+, and 2+ grade in 2 (7.1%), 21 (75.0%), and 5 (17.9%) patients, respectively. Mitral valve gradient was 2.5 (2.0, 3.0) mm Hg. Deaths, thoracotomy conversion, or device complications such as unileaflet clamping, clip dislodgement, or leaflet injury were negative. Twenty-eight (100.0%) patients completed at least 3-month postoperative follow-up with a median follow-up time of 5.9 (3.6, 6.8) months, during which patients had a mean MR grade of 1.0+ (1.0+, 2.0+) grade and a significant improvement from preoperative values (P<0.001). There was no recurrence of ≥3+ regurgitation, pulmonary venous reflux, reoperation, new-onset mitral stenosis, or major adverse cardiovascular events. Twenty-two (78.6%) patients’ cardiac function improved to classⅠorⅡ. Conclusion The domestic KokaclipTM TEER system has shown excellent preliminary clinical results in selected DMR patients with a high safety profile and significant improvement in MR. Additional large sample volume, prospective, multicenter studies, and long-term follow-up are expected to validate the effectiveness of this system in the future.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content