ObjectiveTo observe the effect of spectral-domain OCT with different subfoveal choroidal areas on choroid vascular index (CVI) in normal healthy eyes.MethodsRetrospective clinical study. From October 2017 to May 2018, 174 eyes of 87 healthy people who visited in the Ophthalmology Department of Beijing Friendship Hospital and had no eye abnormalities were included in the study. All patients received single line scan of macular fovea by enhanced depth imaging OCT. After binary processing of the collected choroidal images, CVI as the center radius of 750, 1500, 3000 and 4500 μm were calculated. Repeated measurement analysis of variance was performed for comparison of CVI between groups.ResultsThe mean values of CVI in the 750, 1500, 3000 and 4500 μm groups were 0.681±0.003, 0.678±0.002, 0.677±0.002 and 0.676±0.002, respectively. The difference between the 750 μm group and the 4500 μm group was 0.005±0.002 (P=0.009). The other pairwise comparison results showed no statistically significant difference (P>0.05).ConclusionThe CVI is different in healthy eyes with the different distance from macular fovea.