west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "HAN Xu" 11 results
  • Diagnostic value of miRNAs for Alzheimer’s disease: a meta-analysis

    ObjectiveTo systematically review the diagnostic value of miRNAs for Alzheimer’s disease (AD).MethodsPubMed, Web of Science, EMbase, The Cochrane Library, CNKI, WanFang Data, VIP, and CBM databases were electronically searched to collect diagnostic tests of miRNAs for AD from inception to October 31, 2020. Two researchers independently screened literature, extracted data, and assessed the risk of bias of the included studies. RevMan 5.3 and Stata 14.0 software were used for meta-analysis. ResultsA total of 22 studies involving 4 006 subjects were included. The meta-analysis results showed that the pooled sensitivity, specificity, positive and negative likelihood ratios, diagnostic odds ratio, and the areas under the working characteristic curve of miRNA in AD diagnosis were 0.83 (95%CI 0.79 to 0.87), 0.80 (95%CI 0.76 to 0.83), 4.07 (95%CI 3.37 to 4.92), 0.21 (95%CI 0.17 to 0.27), 19.20 (95%CI 12.96 to 28.48) and 0.88 (95%CI 0.85 to 0.90), respectively. ConclusionThe current evidence shows that miRNAs have a high diagnostic value for AD. However, because of the limited quality and quantity of the included studies, more high-quality studies are required to verify the above conclusion.

    Release date: Export PDF Favorites Scan
  • Predictive value of C-reactive protein/albumin ratio for complications after pancreaticoduodenectomy

    ObjectiveTo evaluate the predictive value of C-reactive protein/albumin ratio (CAR) for postoperative complications of pancreaticoduodenectomy (PD).MethodsThe clinical data of 134 patients with pancreaticoduodenectomy (PD) in the Department of Pancreatic Surgery of The First Affiliated Hospital of Xinjiang Medical University from 2015 to 2018 were retrospectively collected, including general conditions and postoperative complications. The predictive value of CAR was calculated.ResultsOf the 134 patients, 38 patients suffered from postoperative pancreatic fistula (POPF), 32 patients suffered from abdominal infection, 5 patients suffered from biliary fistula, 63 patients suffered from delayed gastric emptying (DGE), 13 patients suffered from post pancreatectomy hemorrhage (PPH), 8 patients suffered from wound infection, and 1 patient suffered from chyle leakage. There was no significant difference in general conditions such as gender, age, BMI, American Society of Anesthesiologists (ASA) score, tumor nature, tumor diameter, operative time, intraoperative blood loss, diabetes history, jaundice history, and drinking history (P>0.05), but the hospital stay in the complication group was longer than that of the non-complication group (P<0.05). The value of CAR in the pancreatic fistula and abdominal infection group were significantly higher than those in the non-complication group at 1 d, 3 d and 5 d (exclude 1 day after surgery on POPF), the difference was statistically significant (P<0.05). On the 3rd day after surgery, the sensitivity of CAR predicting POPF was 79.95%, the specificity was 86.46%; the sensitivity of predicting abdominal infection was 75.00%, the specificity was 81.37%, and the result was better than using procalcitonin (PCT) alone, but similar with C-reactive protein (CRP) alone or CRP+PCT.ConclusionPostoperative CAR can better predict POPF and abdominal infection after PD, and the effect is better than PCT alone.

    Release date:2020-02-28 02:21 Export PDF Favorites Scan
  • Short-term effectiveness of arthroscopic single bundle four-strand reconstruction using autologous semitendinosus tendon and anterior half of peroneus longus tendon for posterior cruciate ligament injuries

    ObjectiveTo investigate the short-term effectiveness of arthroscopic single bundle four-strand reconstruction using autologous semitendinosus tendon and anterior half of peroneus longus tendon for posterior cruciate ligament (PCL) injuries.MethodsA clinical data of 30 patients with PCL injury, who were admitted between December 2015 and September 2018 and met the selection criteria, was retrospectively analyzed. All patients were treated with arthroscopic single bundle four-strand reconstruction using autologous semitendinosus tendon and anterior half of peroneus longus tendon and TightRope technique. Among them, 19 were male and 11 were female, aged 17-48 years (mean, 28.2 years). The PCL injury was caused by traffic accident in 8 cases, sport in 14 cases, falling and bruising by a heavy objective in 5 cases, and other injuries in 3 cases. The interval between injury and operation was 10-90 days (mean, 39.3 days). The PCL injury was rated as grade Ⅱ in 6 cases and grade Ⅲ in 24 cases. The posterior drawer test was positive in 26 cases and the inverse Lachman test was positive in 24 cases. The International Knee Documentation Committee (IKDC) score was 61.37±8.49, and the objective IKDC ligament grading was near normal in 2 cases, abnormal in 8 cases, and significantly abnormal in 20 cases. The modified Lysholm knee score was 62.20±5.67. The knee range of motion (ROM) was (101.83±8.15) °.ResultsThe operative time ranged from 70 to 110 minutes (mean, 79.7 minutes). All incisions healed by first intetion. All patients were followed up 12-24 months (mean, 19.0 months). There were 3 cases of deep vein thrombosis in the lower extremity after operation, and 1 case of approximately 10° limitation of knee extension. At last follow-up, the posterior drawer test was positive in 2 cases and the inverse Lachman test was positive in 1 case, with significant differences compared with the preoperative period (χ2=38.571, P=0.000; χ2=36.274, P=0.000). The IKDC score was 84.67±3.67, and the objective IKDC ligament grading was normal in 16 cases, nearly normal in 10 cases, abnormal in 3 cases, and significantly abnormal in 1 case; the modified Lysholm knee score was 90.37±4.49; all of the above indexes were significantly better than preoperative ones, and the differences were significant (t=−12.387, P=0.000; Z=−2.810, P=0.005; t=−22.865, P=0.000). Knee ROM was (88.33±9.86)° at 1 month after operation and reached (113.33±13.48)° at last follow-up, showing significant differences between pre- and post-operation (P<0.05). MRI re-examination showed that the form and position of reconstructed PCL were satisfactory.ConclusionIt can obtain good short-term effectiveness for PCL injuries by arthroscopic single bundle four-strand reconstruction using autologous semitendinosus tendon and anterior half of peroneus longus tendon, which has the advantages of reliable surgical approach, safe operation, and precise effectiveness.

    Release date:2021-06-07 02:00 Export PDF Favorites Scan
  • Application value of lower abdominal aorta compression in hysterectomy for pernicious placenta previa

    Objective To explore the value of lower abdominal aorta compression in emergent hysterectomy during cesarean section because of pernicious placenta previa. Method We retrospectively analyzed the clinical data of four patients who underwent hysterectomy for pernicious placenta previa with the assistance of lower abdominal aorta compression between January 2016 and March 2017 in Sichuan Provincial Hospital for Women and Children. Result The four patients were cured successfully, and the mothers and babies were all well with no pelvic organ damage or complications related to lower abdominal aorta compression. Conclusions Lower abdominal aorta compression in hysterectomy for pernicious placenta previa during cesarean section is a feasible procedure; it can effectively reduce the amount of bleeding, less affect maternal blood circulation, make surgery area clear, and give the operators the chance to do hysterectomy calmly. Lower abdominal aorta compression presents more and more advantages to treat pernicious placenta previa and may be an effective emergency measure to reduce hemorrhage during perioperative period especially under the circumstances of no chance to carry out vascular intervention treatment.

    Release date:2017-10-27 11:09 Export PDF Favorites Scan
  • Research on thorax impact injury of children at different ages based on finite element models

    The pediatric cadaver impact experiments were reconstructed using the validated finite element(FE) models of the 3-year-old and 6-year-old children. The effect of parameters, such as hammer size, material parameters and thorax anatomical structure characteristics, on the impact mechanical responses of 3-year-old and 6-year-old pediatric thorax was discussed by designing reasonable finite element simulation experiments. The research results showed that the variation of thorax contact peak force for 3-year-old group was far larger than that of 6-year-old group when the child was impacted by hammers with different size, which meant that 3-year-old child was more sensitive to hammer size. The mechanical properties of thoracic organs had little influence on the thorax injury because of the small difference between 3-year-old and 6-year-old child in this research. During the impact, rib deformation led to different impact location and deformation of internal organs because the 3-year-old and 6-year-old children had different geometrical anatomical structures, such as different size of internal organs. Therefore, the injury of internal organs in the two groups was obviously different. It is of great significance to develop children finite element models with high biofidelity according to its real anatomical structures.

    Release date:2018-10-19 03:21 Export PDF Favorites Scan
  • Arthroscopic reconstruction of medial patellofemoral ligament combined with medial displacement of lateral hemitibial tuberosity for treatment of recurrent dislocation of patella

    ObjectiveTo observe the effectiveness of arthroscopic reconstruction of medial patellofemoral ligament (MPFL) with a single bundle of autogenous half peroneal longus tendon, and medial displacement of lateral hemitibial tuberosity for the treatment of recurrent dislocation of patella.Methods Retrospectively analyse the clinical data of 24 patients (24 knees) with recurrent patellar dislocation with tibial tuberosity-trochlear groove distance (TT-TG) values more than 15 mm who were admitted between September 2014 and September 2018. Of which 7 were male and 17 were female; aged 16-35 years old with an average of 25.8 years. The disease duration ranged from 15 to 46 months, with an average of 26.7 months. All patients had a history of knee trauma, and a positive result of apprehension test on the affected knee. All patients underwent the surgery of arthroscopic reconstruction of MPFL with a single bundle of autogenous half peroneal longus tendon, and medial displacement of lateral hemitibial tuberosity. Before and after operation, Kujala score was used to evaluate patellofemoral joint function, Lysholm score was used to evaluate knee joint function; CT and MRI were used to measure and compare the changes of congruence angle (CA), patellar tilt angle (PTA), and lateral patella displacement (LPD) in order to evaluate patella stability.ResultsAll incisions healed by first intention, and no infection or neurovascular injury occurred. Deep vein thrombosis of the lower extremities occurred in 2 cases at 4 and 7 days after operation respectively, and the thrombosis disappeared after symptomatic treatment. All the 24 patients were followed up 12-14 months (mean, 12.9 months). During follow-up, no patellar dislocation reoccurred in the affected knee. At last follow-up, the apprehension test was negative in every patients. The TT-TG, CA, PTA, and LPD were significantly improved when compared with those before operation (P<0.05). The Kujala score and Lysholm score at 1 month and last follow-up were significantly better than those before operation, and the above scores at last follow-up were significantly better than those at 1 month after operation (P<0.05). According to Lysholm score, the patients’ knee joint functions were excellent in 13 cases, good in 10 cases, and fair in 1 case, and the excellent and good rate was 95.8%.ConclusionArthroscopic reconstruction of MPFL with a single bundle of autogenous half peroneal longus tendon combined with medial displacement of lateral hemitibial tuberosity has the advantages of minimal invision and reliable effectiveness. It can be used as one of the effective surgical methods for the treatment of recurrent dislocation of patella.

    Release date:2020-07-27 07:36 Export PDF Favorites Scan
  • Clincal observation of non-absorbable suture cerclage combined with patella claw fixation for treatment of inferior patella fractures

    ObjectiveTo investigate the effectiveness of non-absorbable suture cerclage combined with patella claw fixation for the treatment of inferior patella fractures.MethodsBetween September 2016 and January 2019, 22 patients with inferior patella fractures were treated. There were 12 males and 10 females, with a mean age of 49.1 years (range, 32-67 years). The causes of injury were traffic accident in 8 cases, falling in 12 cases, and other causes in 2 cases. The interval from injury to operation was 3-7 days (mean, 4.4 days). For the operation, 3 or 4 longitudinal tunnels were drilled backward from the surface of the proximal fracture fragment with Kirschner wires; under the guidance of lumbar puncture needles and steel wires, non-absorbable suture passed through the tunnels and encircled the inferior fracture fragment, then tighten to achieve a satisfactory reduction of the fracture; finally, the patella claw was used to strengthen the fixation. During the follow-up, complications were observed, maximum motion range of the knee joint was measured, X-ray examination was performed and fracture healing time was recorded. The knee function was evaluated according to Böstman scores.ResultsAll the 22 patients were followed up 12-36 months (mean, 19.4 months). No infection, joint stiffness, bone nonunion, loss of reduction, or displacement of internal fixation occurred. All fractures were clinically healed, and the bone healing time was 2-3 months (mean, 2.6 months). At last follow-up, the maxium motion range of knee joint was 130°-135°, with an average of 132.6°. The Böstman score of the affected knee was 28-30 (mean, 29.2). All cases were graded as excellent results.ConclusionNon-absorbable suture cerclage combined with patella claw fixation for inferior patella fractures has the advantages of simple operation, reliable fixation, and few complications, and the clinical results are satisfactory.

    Release date:2020-11-02 06:24 Export PDF Favorites Scan
  • Endoscopic thoracic sympathicotomy in the treatment of primary hyperhidrosis based on ambulatory surgery and enhanced recovery mode: A retrospective cohort study in a single center

    ObjectiveTo investigate the safety of endoscopic thoracic sympathicotomy in the treatment of primary hyperhidrosis based on ambulatory surgery mode.MethodsRetrospective analysis was performed on the clinical data of 158 patients with primary hyperhidrosis who received endoscopic thoracic sympathicotomy in the Affiliated Hospital of Zunyi Medical University from January 2019 to March 2021. There were 68 (43.2%) males and 90 (56.8%) females with an average age of 14-33 (20.5±3.1) years. The basic information of the patients, operation time, intraoperative blood loss, postoperative pain score, hospitalization expenses and postoperative complications were observed and recorded.ResultsAll surgeries were successfully completed and the patients were discharged as planned. The operation time was 41.8±13.9 min, the intraoperative blood loss was 10.5±7.3 mL, the postoperative anesthesia recovery time was 15.0±5.9 min, and the pain score was 3.0±0.9 points. The total length of hospitalization was 1.6±1.0 days. The total postoperative expenses were 9 471.7±1 698.9 yuan. Pneumothorax occurred after the operation in 3 patients. Telephone follow-up on the 30th day after the operation showed no recurrence of sweaty hands, pneumothorax or rapid heart rate, and no serious complications or death related to the day operation within 30 days after the operation.ConclusionEndoscopic thoracic sympathicotomy based on ambulatory surgery mode is safe and effective in the treatment of primary hyperhidrosis.

    Release date: Export PDF Favorites Scan
  • Short-term results of valve-in-valve transcatheter aortic valve implantation in patients with degenerated bioprosthesis

    Objective To summarize the short-term results of valve-in-valve transcatheter aortic valve implantation (ViV-TAVI) in the treatment of bioprosthetic valve failure after aortic valve replacement. Methods We reviewed the clinical data of patients who underwent ViV-TAVI from 2021 to 2022 in the First Affiliated Hospital of Zhengzhou University. The valve function was evaluated by echocardiography before operation, immediately after operation and 3 months after operation. The all-cause death and main complications during hospitalization were analyzed. Results A total of 13 patients were enrolled, including 8 males and 5 females with a mean age of 65.9±8.5 years, and the interval time between aortic valve replacement and ViV-TAVI was 8.5±3.4 years. The Society of Thoracic Surgeons mortality risk score was 10.3%±3.2%. None of the 13 patients had abnormal valve function after operation. The mean transvalvular differential pressure of aortic valve was decreased (P<0.001), the peak flow velocity of aortic valve was decreased (P<0.001), the left ventricular ejection fraction was not changed significantly (P=0.480). There were slight perivalvular leakage in 2 patient and slight valve regurgitation in 3 patients. Three months after operation, the mean transvalvular pressure difference and peak flow velocity of aortic valve in 12 patients were significantly different from those before operation (P≤0.001). Conclusion This study demonstrates that ViV-TAVI for the treatment of bioprosthetic valve failure after aortic valve replacement is associated with sustained clinical and functional cardiovascular benefits, the short-term results are satisfactory.

    Release date: Export PDF Favorites Scan
  • Research progress of video-assisted anal fistula treatment for anal fistula

    Objective To summarize the research progression of video-assisted anal fistula treatment (VAAFT). Methods The related literatures in recent years were reviewed, and then the operation principle, operation process, advantages and disadvantages, matters needing attention, and clinical application of VAAFT were summarized. Results VAAFT is the treatment of fistulas by endoscopy. It don’t require the incision or resection of the fistula. It has the advantages of less surgical trauma, faster postoperative recovery, and less impact on the anal sphincter. The disadvantage of this method is relatively strict indications, fistula bending or horseshoe fistula is not suitable for this method. In addition, the endoscope using during the operation is a rigid mirror tube, and the operation is not convenient enough, so technical improvement is needed in the future. We should pay attention to distinguish true fistula and false fistula in clinical practice; the wall of the fistula should be adequately burned and the necrotic tissue should be cleaned; the treatment of the internal opening of anal fistula must be exact; the time of the first defecation should be appropriately delayed, and the incidence of infection should be reduced after operation. At present, the clinical reports of VAAFT are increasing gradually in foreign countries, and these reports have achieved good therapeutic effect. It is considered that this method maybe a safe and effective minimally invasive surgical treatment for anal fistula. However, there is few clinical reports on VAAFT in China, and it is still in the preliminary stage of exploration. Conclusion VAAFT is a new technology in the treatment of anal fistula, and it has advantages of minimally invasive, sphincter preservation, and so on, which is worthy of clinical application.

    Release date:2017-12-15 06:04 Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content