west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "HAO Peng" 5 results
  • THE APPLICATION OF BASIC FIBROBLAST GROWTH FACTOR IN TENDON TISSUE ENGINEERING

    Objective To review the recent researches of basic fibroblast growth factor (bFGF) in tendon tissue engineering. Methods Recentoriginal related literature was extensively reviewed and analyzed. Results bFGF played an important role in establishing standard tendon tissue engineering cell lines, inducing the compound and analysis of extracellular matrix, enhancing interactions between cells and extracellular matrix and accelerating tissue engineering materials’ neovascularization. Conclusion The progresses in increasing endogenetic bFGF expression, controlling the release of exogenous bFGF and improving the bioutilization of bFGF has laid foundation for wider use of bFGF in tendon tissue engineering.

    Release date:2016-09-01 09:28 Export PDF Favorites Scan
  • Clinical application of distal femoral patient-specific cutting guide based on knee CT and full-length X-ray film of lower extremities

    ObjectiveTo discuss the feasibility and accuracy of distal femoral patient-specific cutting guide in total knee arthroplasty (TKA) based on knee CT and full-length X-ray film of lower extremities. MethodsBetween July 2016 and February 2017, 20 patients with severe knee joint osteoarthritis planned to undergo primary TKA were selected as the research object. There were 9 males and 11 females; aged 53-84 years, with an average of 69.4 years. The body mass index was 22.1-31.0 kg/m2, with an average of 24.8 kg/m2. The preoperative range of motion (ROM) of the knee joint was (103.0±19.4)°, the pain visual analogue scale (VAS) score was 5.4±1.3, and the American Hospital of Special Surgery (HSS) score was 58.1±11.3. Before operation, a three-dimensional model of the knee joint was constructed based on the full-length X-ray film of lower extremities and CT of the knee joint. The distal femoral patient-specific cutting guide was designed and fabricated, and the thickness of the distal femoral osteotomy was determined by digital simulation. The thickness of the internal and external condyle of the distal femur osteotomy before operation and the actual thickness of the intraoperative osteotomy were compared. The intraoperative blood loss, postoperative drainage loss, and hidden blood loss were recorded. The ROM of knee joint, VAS score, and HSS score at 3 months after operation were recorded to evaluate effectiveness. The position of the coronal and sagittal plane of the distal femoral prosthesis were assessed by comparing the femoral mechanical-anatomical angle (FMAA), anatomical lateral distal femoral angle (aLDFA), mechanical femoral tibial angle (mFTA), distal femoral flexion angle (DFFA), femoral prosthesis flexion angle (FPFA), anatomical lateral femoral component angle (aLFC), and the angle of the femoral component and femoral shaft (α angle) between pre- and post-operation.ResultsTKA was successfully completed with the aid of the distal femoral patient-specific cutting guide. There was no significant difference between the thickness of the internal and lateral condyle of the distal femur osteotomy before operation and the actual thickness of the intraoperative osteotomy (P>0.05). All patients were followed up 3 months. All incisions healed by first intention, and there was no complications such as periarticular infection and deep vein thrombosis. Except for 1 patient who was not treated with tranexamic acid, the intraoperative blood loss of the rest 19 patients ranged from 30 to 150 mL, with an average of 73.2 mL; the postoperative drainage loss ranged from 20 to 500 mL, with an average of 154.5 mL; and the hidden blood loss ranged from 169.2 to 1 400.0 mL, with an average of 643.8 mL. At 3 months after operation, the ROM of the knee was (111.5±11.5)°, and there was no significant difference when compared with the preoperative one (t=–1.962, P=0.065). The VAS score was 2.4±0.9 and HSS score was 88.2±7.5, showing significant differences when compared with the preoperative ones (t=7.248, P=0.000; t=–11.442, P=0.000). Compared with the preoperative measurements, there was a significant difference in mFTA (P<0.05), and there was no significant difference in aLDFA, FMAA, or DFFA; compared with the preoperative plan, there was no significant difference in FPFA, aLFC, or α angle (P>0.05). ConclusionThe use of distal femoral patient-specific cutting guide based on knee CT and full-length X-ray film of lower extremity can achieve precise osteotomy, improve coronal and sagittal limb alignment, reduce intraoperative blood loss, and obtain satisfactory short-term effectiveness.

    Release date:2021-02-24 05:33 Export PDF Favorites Scan
  • Effect of three-dimensional printing guide plate on improving femoral rotational alignment and patellar tracking in total knee arthroplasty

    ObjectiveTo investigate the effect of three-dimensional (3D) printing guide plate on improving femoral rotational alignment and patellar tracking in total knee arthroplasty (TKA).MethodsBetween January 2018 and October 2018, 60 patients (60 knees) with advanced knee osteoarthritis who received TKA and met the selection criteria were selected as the study subjects. Patients were randomly divided into two groups according to the random number table method, with 30 patients in each group. The TKA was done with the help of 3D printing guide plate in the guide group and following traditional procedure in the control group. There was no significant difference in gender, age, disease duration, side, and preoperative hip-knee-ankle angle (HKA), posterior condylar angle (PCA), patella transverse axis-femoral transepicondylar axis angle (PFA), Hospital for Special Surgery (HSS) score, and American Knee Society (AKS) score (P>0.05).ResultsAll incisions healed by first intention and no complications related to the operation occurred. All patients were followed up 10-12 months, with an average of 11 months. HSS score and AKS score of the two groups at 6 months after operation were significantly higher than those before operation (P<0.05), but there was no significant difference between the two groups (P>0.05). Postoperative X-ray films showed that the prosthesis was in good position, and no prosthesis loosening or sinking occurred during follow-up. HKA, PCA, and PFA significantly improved in the two groups at 10 months after operation compared with those before operation (P<0.05). There was no significant difference in HKA at 10 months between the two groups (t=1.031, P=0.307). PCA and PFA in the guide group were smaller than those in the control group (P<0.05).ConclusionApplication of 3D printing guide plate in TKA can not only correct the deformity of the knee joint and alleviate the pain symptoms, but also achieve the goal of the accurate femoral rotation alignment and good patellar tracking.

    Release date:2020-04-15 09:18 Export PDF Favorites Scan
  • Analysis of gait and effectiveness after unicompartmental knee arthroplasty

    ObjectiveTo explore the gait trajectory characteristics and effectiveness after unicompartmental knee arthroplasty (UKA).MethodsThirty patients (30 knees) with anterior medial compartment osteoarthritis who were treated with UKA between January 2017 and December 2018 were selected as subjects (UKA group). According to age, gender, and side, 30 patients (30 knees) with knee osteoarthritis treated with total knee arthroplasty (TKA) were selected as control (TKA group). In addition to the range of motion (ROM) before operation showing significant difference between the two groups (t=4.25, P=0.00), there was no significant difference in gender, age, disease duration, sides, body mass index, and preoperative hip-knee-ankle angle (HKA), Western Ontario and McMaster University Osteoarthritis Index (WOMAC) score between the two groups (P>0.05). The incision length, drainage volume within 24 hours after operation, and the changes of hemoglobin and albumin were recorded. The WOMAC score, ROM, and HKA before and after operation were compared between the two groups. At 1 year after operation, the gait trajectory characteristics of two groups were analyzed by Vicon three-dimensional gait capture system, and the absolute symmetry index (ASI) of the lower limbs of the two groups was calculated.ResultsThe incisions of the two groups healed by first intention, with no complications. The incision length, drainage volume within 24 hours, and the changes of hemoglobin and albumin after operation in the UKA group were significantly smaller than those in the control group (P<0.05). All patients were followed up completely, the follow-up time ranged from 13 to 20 months of UKA group (mean, 18 months) and 16 to 24 months of control group (mean, 20 months). The imaging review showed that the lower limb alignment of the two groups were restored to a neutral position, and the position of prosthesis was good. At 1 year after operation, the WOMAC score, HKA, and ROM of two groups were significantly improved when compared with those before operation (P<0.05); the postoperative WOMAC score and ROM of the UKA group were significantly better than those of the control group (P<0.05), and there was no significant difference in HKA between the two groups (t=1.54, P=0.13). Gait analysis at 1 year after operation showed that the walking speed, stride length, knee extension at mid-stance, and flexion at swing in the UKA group were significantly better than those in the TKA group (P<0.05); there was no significant difference in cadence, knee flexion at initial contact, and knee flexion at loading response between the two groups (P>0.05). The ASI of bilateral knee flexion in the UKA group was significantly greater than that in the TKA group during the initial contact and loading response period (P<0.05).ConclusionCompared with TKA, UKA has the advantages of small incision, less blood loss, and quicker functional recovery. The early gait after UKA is mainly manifested as the increase in walking speed, stride length, knee flexion at swing, and extension at mid-stance phase. From the analysis of gait symmetry, during the initial contact and loading response phase, the operation side after UKA undertakes more shock absorption and joint stabilization functions than the contralateral side.

    Release date:2020-11-27 06:47 Export PDF Favorites Scan
  • Comparative study of orthopaedic robot-assisted minimally invasive surgery and open surgery for limb osteoid osteoma

    Objective To compare the accuracy and effectiveness of orthopaedic robot-assisted minimally invasive surgery versus open surgery for limb osteoid osteoma. Methods A clinical data of 36 patients with limb osteoid osteomas admitted between June 2016 and June 2023 was retrospectively analyzed. Among them, 16 patients underwent orthopaedic robot-assisted minimally invasive surgery (robot-assisted surgery group), and 20 patients underwent tumor resection after lotcated by C-arm X-ray fluoroscopy (open surgery group). There was no significant difference between the two groups in the gender, age, lesion site, tumor nidus diameter, and preoperative pain visual analogue scale (VAS) scores (P>0.05). The operation time, lesion resection time, intraoperative blood loss, intraoperative fluoroscopy frequency, lesion resection accuracy, and postoperative analgesic use frequency were recorded and compared between the two groups. The VAS scores for pain severity were compared preoperatively and at 3 days and 3 months postoperatively.Results Compared with the open surgery group, the robot-assisted surgery group had a longer operation time, less intraoperative blood loss, less fluoroscopy frequency, less postoperative analgesic use frequency, and higher lesion resection accuracy (P<0.05). There was no significant difference in lesion resection time (P>0.05). All patients were followed up after surgery, with a follow-up period of 3-24 months (median, 12 months) in the two groups. No postoperative complication such as wound infection or fracture occurred in either group during follow-up. No tumor recurrence was observed during follow-up. The VAS scores significantly improved in both groups at 3 days and 3 months after surgery when compared with preoperative value (P<0.05). The VAS score at 3 days after surgery was significantly lower in robot-assisted surgery group than that in open surgery group (P<0.05). However, there was no significant difference in VAS scores at 3 months between the two groups (P>0.05). Conclusion Compared with open surgery, robot-assisted resection of limb osteoid osteomas has longer operation time, but the accuracy of lesion resection improve, intraoperative blood loss reduce, and early postoperative pain is lighter. It has the advantages of precision and minimally invasive surgery.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content