west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "HE Xiaoqing" 15 results
  • Recent advances in flap surgery

    In recent years, flap surgery has been well-developed, and many theories and techniques of flap surgery have been updating. The purpose of manuscript which is based on the flap-related literature is to summarize recent developments of basic and clinic researches, indicate the future of the flap surgery, and show the consensus and guidelines of flap surgery made by Chinese experts.

    Release date:2018-07-12 06:19 Export PDF Favorites Scan
  • Precise diagnosis and treatment of spastic cerebral palsy

    ObjectiveTo summarize the advancement of precise diagnosis and treatment for spastic cerebral palsy in recent years.MethodsThe literature and own experiences were reviewed, and the surgical method, precise diagnosis, and personalized treatment of spastic cerebral palsy based on the classification of spastic cerebral palsy were summarized and analyzed.ResultsThe common classification of spastic cerebral palsy are gross motor function classification system (GMFCS) and manual ability classification system (MACS). The surgical methods of spastic cerebral palsy can be divided into soft tissue surgery, nerve surgery, and bone and joint surgery. The precise diagnosis of spastic cerebral palsy includes qualitative diagnosis, localization diagnosis, and quantitative diagnosis. Based on precise diagnosis and classification, one or more corresponding surgical methods are selected for treatment.ConclusionThe manifestations of spastic cerebral palsy are so diverse that it is necessary to select rational surgeries based on precise diagnosis to achieve individualized treatment.

    Release date:2019-12-23 09:44 Export PDF Favorites Scan
  • Nitinol memory alloy two foot fixator with autologous cancellous bone grafting for old scaphoid fracture and nonunion

    ObjectiveTo summarize the effectiveness of nitinol memory alloy two foot fixator with autologous cancellous bone grafting in treating old scaphoid fracture and nonunion.MethodsBetween January 2013 and January 2017, 11 patients of old scaphoid fracture and nonunion were treated with nitinol memory alloy two foot fixator and autologous cancellous bone grafting. All patients were male with an average age of 26.1 years (range, 18-42 years). The fractures were caused by sport in 3 cases, falling in 7 cases, and a crashing object in 1 case. The interval between injury and operation was 6-18 months (mean, 8.9 months). Postoperative outcome measures included operation time, fracture healing time, grip strength, range of motion (ROM) of flexion, extension, ulnar deviation, and radial deviation, Mayo score, visual analogue scale (VAS) score, and the Disabilities of the Arm, Shoulder, and Hand (DASH) score.ResultsThe operation time was 35-63 minutes (mean, 48 minutes). All incisions had primary healing with no infection and loosening or breakage of internal fixator. All patients were followed up 12-30 months (mean, 20.7 months). X-ray films showed that fracture healing was achieved in all patients with an average time of 15 weeks (range, 12-25 weeks). All internal fixators were removed after 10-12 months of operation (mean, 11.2 months). At last follow-up, the grip strength, ROMs of flexion, ulnar deviation, and radial deviation were superior to those before operation (P<0.05), no significant difference was found in ROM of extension between pre- and post-operation (t=0.229, P=0.824). There were significant differences in above indexes between affected and normal sides (P<0.05). At last follow-up, the Mayo, VAS, DASH scores were also significantly superior to those before operation (P<0.05).ConclusionFor the old scaphoid fracture and nonunion, Ni-Ti arched shape-memory alloy fixator and autologous cancellous bone grafting can obtain good effectiveness, which is an effective treatment.

    Release date:2020-07-07 07:58 Export PDF Favorites Scan
  • Long-term effectiveness of Ni-Ti memory alloy tripod fixator in treatment of Kienböck disease

    Objective To investigate the long-term effectiveness of Ni-Ti memory alloy tripod fixator in the treatment of Kienböck disease. Methods The clinical data of 22 patients with Kienböck disease who were treated with Ni-Ti memory alloy tripod fixator between January 2011 and September 2013 and followed up more than 10 years was retrospectively analyzed. There were 14 males and 8 females with an average age of 45 years (range, 20-64 years). The Lichtman staging was stage Ⅲb. According to AO/Association for the Study of Internal Fixation (AO/ASIF) classification, there were 6 cases of type B1, 2 cases of type B2, 10 cases of type B3, and 4 cases of type C2. The disease duration ranged from 18 to 50 months, with an average of 30.7 months. The operation time, intraoperative blood loss, and complications were recorded. Wrist height ratio and scapholunate angle were measured by wrist anteroposterior and lateral X-ray films before and after operation. The grip strength of bilateral hands was measured by Jamar dynamometer. The wrist pain was evaluated by visual analogue scale (VAS) score, and the wrist function was evaluated by Mayo score, and the radial deviation, ulnar deviation, dorsiflexion, and palmar flexion range of motion of wrist were measured. Results The operation time was 45-60 minutes, with an average of 52.21 minutes; the intraoperative blood loss was 50-60 mL, with an average of 58.63 mL. No nerve or blood vessel injury occurred during operation. All patients were followed up 10-13 years (mean, 11.3 years). X-ray films at 3 months after operation showed that the density of lunate bone was lower than that before operation. Satisfactory fusion of the scapho-trapezio-trapezoeid joint was achieved at 3-6 months after operation (mean, 4.5 months), and the wrist height ratio and the scapholunate angle after fusion significantly improved when compared with those before operation (P<0.05). Wrist pain relieved, scaphoid rotation and dislocation improved, and no radiocarpal joint degeneration was found during follow-up, and no internal fixator loosening, breakage, or lunate bone necrosis occurred. At last follow-up, the wrist radial deviation, ulnar deviation, dorsiflexion, and palmar flexion range of motion, VAS score, and grip strength of the affected side significantly improved when compared with those before operation (P<0.05); the grip strength of the affected side recovered to 99.00%±1.25% of the healthy side. Mayo score ranged from 72 to 93, with an average of 85; 14 cases were rated as excellent, 5 good, and 3 satisfactory, the excellent and good rate was 86.4%. ConclusionIn the treatment of stage Ⅲb Kienböck’s disease, the scapho-trapezio-trapezoeid joint usion using Ni-Ti memory alloy tripod fixator can effectively reduce pain, improve hand function, and prevent further deterioration, and achieve good long-term effectiveness.

    Release date: Export PDF Favorites Scan
  • PREPARATION OF CATIONIC VANCOMYCIN HYDROCHLORIDE MULTIVESICULAR LIPOSOMES AND ITS QUALITY

    Objective To prepare cationic Vancomycin hydrochloride multivesicular liposome (MVL) and to inspect its quality. Methods Cationic Vancomycin hydrochloride MVLs were prepared by double emulsion method, and the storing solution of Vancomycin was prepared. The analysis method of Vancomycin in vitro was established; the specificity, precision, and resorption rate were estimated. Reverse phase high performance liquid chromatography (RP-HPLC) was used to determine the concentration of Vancomycin, encapsulation efficiency, and release characteristics in vitro. The formulation and pharmaceutical process were optimized by single factor experiments and orthogonal experimental design with the factor of encapsulation efficiency as the criteria. The liposome morphology was observed by optical microscopy and transmission electron microscopy. The particle size and Zeta potential were determined by Malvern instrument. The stability was analyzed by dynamic analysis. Results An RP-HPLC method was established for the assay of Vancomycin. The analysis method was precise, simple, and reliable for the quality control of Vancomycin. Vancomycin hydrochloride MVLs were round and well-distributed. The average particle size and the encapsulation efficiency were 3.3 μm and 24.9%, respectively. Zeta potential was 24.53 mV, and 90.5% of Vancomycin hydrochloride was released after 264 hours in normal saline under 37℃. Cationic Vancomycin MVLs were stored for 1 month at 4 ℃, which mantained good stability. Conclusion Cationic Vancomycin hydrochloride MVLs have good appearance, high encapsulation efficiency, good stability, and significant sustained release properties.

    Release date:2016-08-31 04:07 Export PDF Favorites Scan
  • Establishment of micro-vessels model of cross-boundary perforator flap in rat via digital technology

    Objective To investigate the feasibility and application value of digital technology in establishing the micro-vessels model of cross-boundary perforator flap in rat. Methods Twenty 8-week-old female Sprague Dawley rats, weighing 280-300 g, were used to established micro-vessels model. The cross-boundary perforator flaps of 10 cm×3 cm in size were prepared at the dorsum of 20 rats; then the flaps were suturedin situ. Ten rats were randomly picked up at 3 and 7 days after operation in order to observe the necrosis of flap and measure the percentage of flap necrosis area; the lead-oxide gelatin solution was used for vessels perfusion; flaps were harvested and three-dimensional reconstruction of micro-vessel was performed after micro-CT scanning. Vascular volume and total length were measured via Matlable 7.0 software. Results The percentage of flap necrosis area at 3 days after operation was 19.08%±3.64%, which was significantly lower than that at 7 days (39.76%±3.76%;t=10.361, P=0.029). Three-dimensional reconstruction via the micro-CT clearly showed the morphological alteration of micro-vessel of the flap. At 3 days after operation, the vascular volume of the flap was (1 240.23±89.71) mm3 and the total length was (245.94±29.38) mm. At 7 days after operation, the vascular volume of the flap was (1 036.96±88.97) mm3 and the total length was (143.20±30.28) mm. There were significant differences in the vascular volume and the total length between different time points (t=5.088, P=0.000; t=7.701, P=0.000). Conclusion The digital technology can be applied to visually observe and objectively evaluate the morphological alteration of the micro-vessels of the flap, and provide technical support for the study of vascular model of flap.

    Release date:2017-12-11 12:15 Export PDF Favorites Scan
  • Progress in biocompatibility and surface modification of nickel titanium shape memory alloys

    Objective To summarize the research progress of biocompatibility and surface modification of nickel titanium shape memory alloys (Ni-Ti SMA). Methods The relative researches about Ni-Ti SMA at home and abroad were reviewed, collated, analyzed, and summarized. Results At present, Ni-Ti SMA as an internal fixation material has been widely used in clinic. It has the following advantages: the super elasticity, the shape memory characteristic, the good wear resistance, and the strong corrosion resistance. It also can effectively avoid the internal fixator rupture caused by stress shielding. After surface modification, the biocompatibility of Ni-Ti SMA has been improved. Conclusion The Ni-Ti SMA is the most promising alloy material for the long-term internal fixator because of its excellent material properties.

    Release date:2018-07-30 05:33 Export PDF Favorites Scan
  • Clinical application of digital technology in repairing of heel wound with peroneal artery perforator propeller flap

    ObjectiveTo study the effectiveness of digital technique in repairing of heel wound with peroneal artery perforator propeller flap.MethodsBetween March 2016 and March 2019, the heel wounds of 31 patients were repaired with the peroneal artery perforator propeller flaps. There were 21 males and 10 females, with an average age of 36 years (range, 12-53 years). Seventeen patients were admitted to hospital in emergency after trauma, the time from injury to admission was 6.0-12.5 hours, with an average of 8.5 hours; 14 patients were chronic infectious wounds and ulcer. The wound area ranged from 5 cm×4 cm to 12 cm×8 cm. Before flap repair, CT angiography (CTA) data of lower extremity was imported into Mimics19.0 software and three-dimensional reconstruction of peroneal artery perforator and skin model, accurate location of perforator, accurate design of perforator flap, and simulated operation according to the defect range and location were obtained.ResultsThe origin and course of peroneal artery perforator, the position of perforator, the diameter of perforator, and the maximum length of the naked perforator were determined based on the three-dimensional model. There was no significant difference in locating point of perforator, diameter of perforator, maximum length of naked perforator between the pre- and intra-operative measurements (P>0.05). The position of the lower perforator of the peroneal artery were on the posterolateral lateral ankle tip (5-10 cm) in 31 cases. The total incidence of perforating branches within 10 cm on the tip of lateral malleolus was 96.9%, and the length of vascular pedicle was (3.44±0.65) cm. The flap removal and transposition in 31 patients were successfully completed. The average operation time was 45 minutes (range, 30-65 minutes). After operation, vein crisis and partial necrosis occurred in 4 cases and 3 cases, respectively, which were survived after symptomatic treatment. All the grafts survived and the incisions healed by first intention. All the patients were followed up 3-18 months, with an average of 12 months. At last follow-up, according to the American Orthopaedic Foot and Ankle Society (AOFAS) score, 17 cases were excellent, 11 cases were good, and 3 cases were fair, and the excellent and good rate was 87.5%.ConclusionThe digital technique can improve the accuracy of perforator localization and the design of peroneal artery perforator propeller flap, and reduce the difficulty of operation, and the risk caused by the variation of vascular anatomy.

    Release date:2020-04-15 09:18 Export PDF Favorites Scan
  • Application of digital technology in superficial lateral sural artery perforator flap for tiny hand wounds reconstruction

    Objective To investigate the effectiveness of the digital technology in repairing tiny hand wounds with superficial lateral sural artery perforator flap. Methods Between August 2013 and October 2016, 10 cases of tiny hand wounds were treated with the superficial lateral sural artery perforator flap. There were 6 males and 4 females, aged 19 to 47 years (mean, 31.2 years). The causes included crushing injury by machine in 6 cases, traffic accident injury in 3 cases, and electric burning injury in 1 case. The location of the soft tissue defect was the first web in 2 cases, the thumb pulp in 3 cases, the index finger pulp in 1 case, the dorsal palms in 3 cases, and the dorsum of finger in 1 case. The time from injury to hospitalization was 4 hours to 10 days (mean, 3.5 days). The size of wound was from 4 cm×3 cm to 8 cm×7 cm. All defects were associated with exposure of tendon and bone. CT angiography (CTA) from aortaventralis to bilateral anterior and posterior tibial arteries was performed before operation, and the appropriate donor site as well as perforator was selected. Then the CTA data were imported into the Mimics15.0 software to reconstruct the three dimensional structure of the perforator artery, bone, and skin; according to flap size, the flap design and harvesting process were simulated. The flap was obtained on the basis of preoperative design during operation. The size of flaps varied from 5 cm×4 cm to 10 cm×8 cm. The donor site was sutured directly in 9 cases and repaired with skin grafting in 1 case. Results Superficial medial sural artery peforator was cut in 3 patients whose superficial lateral sural artery was too narrow, and the flaps were obtained to repair defects smoothly in the others. Venous crisis occurred in 1 flap, which survived after exploration of the vessel, thrombus extraction, and thrombolysis; the other flaps survived successfully. All wounds and incisions healed by first intention. All cases were followed up 3-18 months (mean, 10 months). The flaps had good shape. At last follow-up, the results were excellent in 6 cases, good in 3 cases, and fair in 1 case according to total active motion (TAM). Conclusion The preoperative individualized design of the superficial lateral artery perforator flap can realize through CTA digital technology and Mimics15.0 software; it can reduce the operation risk and is one of better ways to repair the tiny hand wounds.

    Release date:2017-05-05 03:16 Export PDF Favorites Scan
  • Biomechanical comparison of three kinds of fixation instruments for calcaneal osteotomy

    ObjectiveTo compare the biomechanical characteristics of self-made nickel-titanium shape memory alloy stepped plate with calcaneal plate and cannulated compression screws in fixing calcaneal osteotomy.MethodsCalcaneal osteotomy was operated on 6 fresh-frozen lower limbs collected from donors. Then three kinds of fixation materials were applied in random, including the self-made nickel-titanium shape memory alloy stepped plate (group A), calcaneal plate (group B), and cannulated compression screws (group C). Immediately after fixation, axial loading of 20-600 N and 20 N/s in speed was introduced to record the biomechanical data including maximum displacement, elastic displacement, and maximum load. Then fatigue test was performed (5 Hz in frequency and repeat 3 000 times) and the same axial loading was introduced to collect the biomechanical data. Finally, the axial compression stiffness before and after fatigue test were calculated.ResultsThere was no significant difference in the axial compression stiffness between pre- and post-fatigue test in each group (P>0.05). However, the axial compression stiffness was significant higher in group A than that in groups B and C both before and after fatigue test (P<0.05). No significant difference was found between group B and group C (P>0.05).ConclusionSelf-made nickel-titanium shape memory alloy stepped plate is better than calcaneal plate and cannulated compression screws in axial load stiffness after being used to fix calcaneal osteotomy.

    Release date:2018-02-07 03:21 Export PDF Favorites Scan