Objective To review the present clinical research situation of adjacent segment degeneration (ASD) after lumbar spinal fusion. Methods The recent literature concerning ASD in the concept, the incidence, the risk factors, and prevention was reviewed. Results The concept of ASD includes radiographic ASD and clinical ASD. The incidences of radiographic ASD and clinical ASD were 8%-100% and 5.2%-18.5%, respectively. The risk factors for ASD include both patient and surgical factors. Patient factors include age, gender, preoperative condition, and so on. Surgical factors include the length of the fusion, mode of fusion, internal fixator, sagittal balance, excessive distraction of disc space, and so on. It can prevent ASD to reduce the length of the fusion, to keep sagittal balance, and to use the non-fusion technology. Conclusion Many researches have proved that the incidence of ASD is increased after lumbar spinal fusion, and it can be reduced by the non-fusion technology. Non-fusion technology has obtained good short-term results. But the long-term results should be further observed because there are some complications.
Objective To investigate the result of the arthroscopicrepair of the meniscus tears with the absorbable sutures. Methods From June 1998 to May2003,the meniscus tears in 110 patients (78 males, 32 females; aged 1466 years, averaged 27.5 years) were repaired with absorbable sutures under an arthroscope. In the patients, there were 93 vertical split injuries, 12 transverse split injuries, and 5 hidden split injuries. There were 78 tears in the lateral margin of the meniscus, 23 tears in the anterior angle of the meniscus, and 9 tears in the posterior angle of the meniscus. Ninetyone patients had 2 sutures, 13 patients had 4 sutures, 4 patients had 6 sutures, and 2 patients had 8 sutures. The rehabilitation program was performed in all the patients postoperatively, and the clinical outcome was observed. The Lysholm score was 57±12 preoperatively. Results Thefollow-up for an average of 26 months (range,12-67 months) showed that 3 patients had a light pain on exertion in the surgically-treated knee;1 patientunderwent an operation again for recurrence of the symptoms due to a failure in the healing of the meniscus tear, so a second arthroscopic operation was performed; and the other patients had a satisfactory result with an excellent knee function. The Lysholm score was 92±7 after operation. Conclusion The arthroscopic repair of the meniscustears has advantages of safety and reliability in the suturing and easier to perform. The repaired meniscus can play much better physiological and biomechanical functions, and will not limit the normal movement of the meniscus during the knee flexion after the sutures are absorbed.
【Abstract】 Objective To evaluate the effectiveness of percutaneous fixation of pelvic fracture by Acutrak full thread headless hollow compression screw. Methods Between March 2008 and April 2010, 31 patients with pelvic fracture underwent percutaneous fixation surgery with Acutrak full thread headless hollow compression screw (surgical group). The effectivenss was compared with those of 14 patients with pelvic fracture treated conservatively (control group). There was no significant difference in age and sex between 2 groups (P gt; 0.05). The injury was more severe in surgical group than in control group. The standard of short-term recovery was active turning over and walking for 5 steps with walking aids. The standard of long-term recovery was pain, gait, fracture healing, and function recovery. Results In surgical group, the other patients reached the standard of short-term recovery at 1-4 days after injury except 1 patient who had sacral plexus injury; in control group, the patients could turn over at 9-13 days (Tile type A2) and 17-25 days (Tile type B2) respectively, and could walk at 17-21 days (Tile type A2) and at 45-57 days (Tile type B2) respectively. The patients of 2 groups were followed up 6-19 months. The time of fracture healing was 2-6 months. The long-term results were excellent in 29 cases and good in 2 cases in surgical group, and were excellent in 8 cases and good in 6 cases in control group, showing significant difference between 2 groups (χ2=6.636, P=0.017).Conclusion Percutaneous internal fixation combined with Acutrak full thread headless hollow compression screw can provide more effective treatment. It can alleviate patients, pain quickly, improve life quality, and has better long-term effectiveness.
Objective To observe the effect of radiofrequency ablation technology for the treatment of infected wounds in minipigs. Methods Infected wounds of full-thickness skin defects (about 6.15 cm2/wound) were prepared in 8 6-month-old minipigs (weighing, 30-35 kg) using the method of Davis et al. The 160 wounds were randomly divided into 4 groups (n=40). Infected wounds were debrided with the radiofrequency ablation technology in group A, with the electric knife in group B, and with the scalpel in group C; no treatment was done in group D as a control. The healing rate, healing time, and tissue filling rate were observed; bacterial quantitative examination and histological examination were done at 0, 2, 7, and 14 days after operation. Results All infected wounds were successfully established after 48 hours when Staphylococcus aureus dilution were inoculated. The wounds after radiofrequency ablation technology treatment were fresh and flat with slight bleeding; the healing time of group A was significantly shorter than that of groups B, C, and D (P lt; 0.05), and the healing rate of group A was significantly higher than that of groups B, C, and D at 7 and 14 days after operation (P lt; 0.05). The tissue filling rate of group A was significantly higher than that of groups B, C, and D at 2 days after operation (P lt; 0.05); the tissue filling rates of groups A, B, and C were significantly higher than that of group D at 7 and 14 days after operation (P lt; 0.05). At 0, 2, 7, and 14 days, there were significant differences in the bacterial count per gram tissue among 4 groups (P lt; 0.05), the order from low to high was groups A, B, C, and D. The histological observation showed that the surface of wound was smooth in group A at 0 day, and group A was better than the other groups in wound healing; at 2 days, some exudates were observed in 4 groups, but it was least in group A. There was inflammatory cell infiltration in various degrees in 4 groups at 7 and 14 days; it was lightest in group A with thick epithelium and dense collagen bundles, followed by groups B and C, and it was severe in group D. Conclusion The radiofrequency ablation technology can effectively remove the necrotic tissues of infected wounds, remarkably reduce the number of bacteria, improve the healing rate, and shorten the healing time of wounds.