west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "HUANG Wei" 48 results
  • BCGpolysaccharide Nucleic Acid Combined with Runzao Antipruritic Capsule in Treating Chronic Urticaria

    目的:观察卡介菌多糖核酸联合润燥止痒胶囊治疗慢性荨麻疹的疗效。方法: 将2008年4月~2009年4月门诊就诊的86例慢性荨麻疹患者随机分成两组,治疗组44例采用卡介菌多糖核酸2 mL肌注,隔日1次,18次为1疗程;同时予口服润燥止痒胶囊4粒,3次/d,连续治疗36天;对照组42例单独口服润燥止痒胶囊,方法疗程同治疗组。结果: 治疗组有效率为90.91%,对照组为7143%。两组比较差异有显著性(Plt;005)。结论: 卡介菌多糖核酸联合润燥止痒胶囊治疗慢性荨麻疹疗效确切。

    Release date:2016-08-26 02:21 Export PDF Favorites Scan
  • Acids-Suppressive Drugs and Ventilator-Associated Pneumoni

    为预防应激性溃疡和消化道出血, 质子泵抑制剂( PPI) 、组胺H2 受体拮抗剂( H2 RA) 以及硫糖铝在ICU中的应用非常普遍。既往的研究认为以PPI 或H2RA 为代表的抑酸剂( ASD) 可致胃液pH 值增高, 为细菌在胃腔内定植创造了条件, 并进而增加医院获得性肺炎( HAP) , 尤其是呼吸机相关性肺炎( VAP) 发生的风险。我们通过文献复习发现,ASD 与VAP 的关联性迄今仍无明确的证据, 已有的临床研究结论互为矛盾; 另一方面, 既往研究多集中于硫糖铝与H2RA 的比较, 有关PPI 和H2RA 导致VAP 的风险比较研究仍然缺乏, PPI 是否比H2 RA 更易发生VAP 也缺乏研究可资证明。为此我们将有关内容综述如下, 以供同道参考。

    Release date:2016-09-14 11:25 Export PDF Favorites Scan
  • Discrimination of HER2 expression in gastric cancer by texture analysis based on plain CT images: a feasibility study

    ObjectiveTo explore the correlation between the texture features of gastric cancer plain CT images and the expression of HER2.MethodsA retrospective collection the datas of 62 patients with gastric cancer who underwent CT scans of the upper abdomen and (or) the whole abdomen from January 2017 to January 2021 in Leshan City People’s Hospital. The treatment method was surgery. The HER2 expression of gastric cancer tissue was detected after the operation. There were 45 male patients and 17 female patients. Lauren classification: 18 cases of intestinal type, 30 cases of diffuse type, and 14 cases of mixed type. Fifty-two cases were HER2 expression negative [age: (63.54±10.32) years], and 10 cases were HER2 expression positive [age: (61.70±11.70) years]. The MaZda module in the MaZda 4.6 version software was used to perform the image normalization, interest area delineation, texture feature extraction, and texture feature selection on the CT plain scan image, and perform texture feature discrimination and misjudgment rate analysis in the B11 module.ResultsThere was no correlation between HER2 expression and age, gender of patients and Lauren classification of tumors (P>0.05). The analysis methods of nonlinear discriminant analysis (NDA)/artificial neural network (ANN), linear discriminant analysis (LDA)/1-nearest-neighbor (1-NN), principal component analysis (PCA)/1-NN, and raw-data analysis (RDA)/1-NN can better correspond to the CT plain scan texture feature parameters of gastric cancer and the expression level of HER2.ConclusionsTexture analysis based on CT plain images has the potential to non-invasively detect the HER2 expression in gastric cancer. The best comprehensive performance texture discrimination method is NDA/ANN and LDA/1-NN.

    Release date:2021-10-18 05:18 Export PDF Favorites Scan
  • Attachments for Mandibular Implant-supported Overdenture: A Systematic Review

    Objective To evaluate clinical outcomes, patient satisfaction, and maintenance after treatment from mandibular implant-supported overdentures with different attachment types. Methods We searched six electronic databases: the Cochrane Central Register of Controlled Trials (CENTRAL, The Cochrane Library, Issue 4, 2005), Current Controlled Trials, MEDLINE (1966 to Sept. 2005), EMBASE (1984 to Sept. 2005), and Chinese biomedical database disk (1978 to Sept. 2005). Eleven Chinese professional journals in oral health were also handsearched from their first published issues. Three authors screened and selected the studies, appraised their methodological quality and extracted data from the studies. The results were presented narratively by meta-analysis. Results After strict screening, 12 trials involving 282 patients were included. Two of the trials were included in a meta-analysis with 27 patients in bar-clip group, 29 patients in ball-spring group, and the other trials were described thoroughly. The findings seemed to indicate that the bar-clip group had the highest retention but more oral mucosa complications, while the ball-spring group had good retention and less oral mucosa complications but needed more aftercare treatments, and the magnetic group had less retention but better peri-implant outcomes. Conclusions There is inadequate evidence to prove which is the best choice for mandibular implant-supported overdentures among bar-clip, ball-spring and magnetic attachments. More controlled clinical trials are required to guide clinicians on the choice of the type of attachment in mandibular implant-supported overdenture.

    Release date:2016-09-07 02:18 Export PDF Favorites Scan
  • Citespace-based visualization analysis of the imaging research progress of gastric cancer

    ObjectiveTo realize the current status and hot issues in the field of gastric cancer imaging research, and to provide references for radiologists and gastrointestinal surgeons to grasp the overall overview of gastric cancer imaging.MethodWe downloaded the relevant literatures of gastric cancer imaging published in 2010–2020 in the Web of Science database, and used Citespace 5.7.R3 software for related visual analysis.ResultsA total of 726 articles in the field of gastric cancer imaging research were retrieved and screened. The number of gastric cancer imaging studies published from 2010 to 2020 was on the rise, with the top three countries published in China, Japan, and the United States. The clusters of co-cited literature on gastric cancer imaging: confocal laser microendoscopy, gastric cancer, gastric mucosal intestinal metaplasia, preoperative T staging, convolutional neural network, deep learning, advanced gastric cancer, in vivo differentiation, early stage gastric cancer, surgical treatment, perigastric lymph nodes, nearest neighbor algorithm, and so on. Hot words in recent research fields included: risk factors, characteristics, deep learning, chemotherapy, and neural networks.ConclusionThe imaging diagnosis of early gastric cancer and the application of artificial intelligence are the research hotspots in this field.

    Release date:2021-02-08 07:10 Export PDF Favorites Scan
  • Application of image texture analysis in diagnosis and treatment of gastric cancer

    ObjectiveTo summarize the application of image texture analysis in the diagnosis and treatment of gastric cancer.MethodsReviewed the literatures on the application of image texture analysis related methods in the diagnosis and treatment of gastric cancer, and summarized the value of texture analysis in the diagnosis and treatment of gastric cancer in terms of diagnosis, staging, curative effect evaluation, and prognosis prediction.ResultsImage texture analysis had been widely used in diagnosis, staging, curative effect evaluation, prognosis prediction of gastric cancer, and other related diagnosis and treatment applications.ConclusionsImage texture analysis is an important part of the diagnosis and treatment of gastric cancer, which has a good development prospect.

    Release date:2021-09-06 03:43 Export PDF Favorites Scan
  • Methodological Evaluation of Clinical Randomized Controlled Trials in Clinical Anesthesiology

    Objective To evaluate the current situation of the design of the randomized controlled trials (RCTs) in Clinical Anesthesiology, Chinese Journal of Anesthesiology and Chinese Journal of Pain Medicine from 1999 to September in 2003. Method The clinical therapeutic studies in the three journals from 1999 to September of 2003 were hand searched over page by page to identify strictly the randomized controlled trials according to Chinese Cochrane Center hand search guideline. Results 412, 378 and 142 papers of the three journals were published, among which, there were 237, 221 and 68 papers of RCT. Conclusions Although the quality of RCT in the three journals has been increased significantly year by year, but there still exist some problems. The quality of RCT papers needs more improvement to guarantee RCT to be more precise as it demands.

    Release date:2016-09-07 02:27 Export PDF Favorites Scan
  • Effects of freeze-drying bovine pericardium using a combination of polyethylene glycol and trehalose

    The freeze-drying is a technology that preserves biological samples in a dry state, which is beneficial for storage, transportation, and cost saving. In this study, the bovine pericardium was treated with a freeze-drying protectant composed of polyethylene glycol (PEG) and trehalose (Tre), and then freeze-dried. The results demonstrated that the mechanical properties of the pericardium treated with PEG + 10% w/v Tre were superior to those of the pericardium fixed with glutaraldehyde (GA). The wet state water content of the rehydrated pericardium, determined using the Karl Fischer method, was (74.81 ± 1.44)%, which was comparable to that of the GA-fixed pericardium. The dry state water content was significantly reduced to (8.64 ± 1.52)%, indicating effective dehydration during the freeze-drying process. Differential scanning calorimetry (DSC) testing revealed that the thermal shrinkage temperature of the pericardium was (84.96 ± 0.49) ℃, higher than that of the GA-fixed pericardium (83.14 ± 0.11) ℃, indicating greater thermal stability. Fourier transform infrared spectroscopy (FTIR) results showed no damage to the protein structure during freeze-drying. Hematoxylin and eosin (HE) staining demonstrated that the freeze-drying process reduced pore formation, prevented ice crystal growth, and resulted in a tighter arrangement of tissue fibers. The frozen-dried bovine pericardium was subjected to tests for cell viability and hemolysis rate. The results revealed a cell proliferation rate of (77.87 ± 0.49)%, corresponding to a toxicity grade of 1. Additionally, the hemolysis rate was (0.17 ± 0.02)%, which is below the standard of 5%. These findings indicated that the frozen-dried bovine pericardium exhibited satisfactory performance in terms of cytotoxicity and hemolysis, thus meeting the relevant standards. In summary, the performance of the bovine pericardium treated with PEG + 10% w/v Tre and subjected to freeze-drying could meet the required standards.

    Release date:2024-04-24 09:50 Export PDF Favorites Scan
  • Clinical histopathological and misdiagnostic analysis of 359 cases of intraocular tumors

    Objective To probe the clinical character,the histopathological classification and misdiagnoses of intraocular tumors. Methods The clinical and pathological data of 359 patients with intraocular tumor diagnosed clinically between 1980~2000 were retrospectively analyzed. Results There were 300 cases of malignant tumor and 23 cases of benign tumor respectively. Non-oncologic malady and benign tumor misdiagnosed as tumor or malignant tumor were 40 cases. The two leading malignant tumors were retinoblastoma and melanoma. Conclusion The clinical and pathological analysis of intraocular tumor is beneficial to the correct clinical diagnosis and treatment. (Chin J Ocul Fundus Dis,2002,18:28-30)

    Release date:2016-09-02 06:01 Export PDF Favorites Scan
  • Development and application of miniaturized and portable ion continuous monitoring technology

    There are already many ion detection methods available, and their development in long-term application practice has become very mature, which can achieve high-precision monitoring of different ion types and ion concentrations. However, in order to meet the requirements of modern smart healthcare, portable ion continuous monitoring methods with good portability, low operational difficulty, and high detection efficiency urgently need to be developed. However, existing detection methods are far from meeting the requirements of real-time and long-term health monitoring due to factors such as detection principles. In recent years, breakthroughs have been made in miniaturized and portable ion continuous monitoring technology, among which high-sensitivity and high-specificity miniature ion sensing components and miniaturized low-power driving measurement circuits have become the main research contents of this technology. This article starts with high-performance ion sensors in the front-end and high-level integrated driving measurement circuits in the back-end, summarizes the current development of miniaturized and portable ion continuous monitoring technology, reviews its applications, and looks forward to the possible development directions of portable ion monitoring technology in the future.

    Release date:2024-08-21 02:11 Export PDF Favorites Scan
5 pages Previous 1 2 3 4 5 Next

Format

Content