west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "Incisional hernia" 11 results
  • The Progression of Diagnosis and Treatment of Abdominal Incisional Hernia

    】ObjectiveTo review the recent studies on the diagnosis and treatment of abdominal incisional hernia. MethodsThe literatures in recent years on the etiological factor,pathology,epidemiology, diagnosis and therapeusis were reviewed and summarized. ResultsThe abdominal incisional hernia is a serious complication of abdominal operation which affect the patient’s quality of life severely. The etiological factors and treatments were complex. Conclusion Prophylaxis of abdominal incisional hernia is important. The tension free hernioplasty using synthetic materials is very popular and effective.

    Release date:2016-08-28 04:47 Export PDF Favorites Scan
  • PREVENTIVE EFFECT OF POLYPROPYLENE MESH BONDED NORVANCOMYCIN SLOW-RELEASE MICROSPHERE ON STAPHYLOCOCCUS AUREUS INFECTION OF INCISIONAL HERNIA REPAIR MODEL

    Objective Mesh infection may occur after incisional hernia repair using prosthetic mesh. Preparation of antibiotics-bonded meshes to prevent infection is one of the solutions. To evaluate the anti-infection effect of polypropylene mesh bonded norvancomycin slow-release microsphere by preparing the rat model of incisional hernia repair contaminatedwith Staphylococcus aureus. Methods The norvancomycin slow-release microspheres were prepared by emulsion and solvent evaporation method and they were bonded to polypropylene mesh (50 mg/mesh). The appearance of the microspheres was observed using scanning electronic microscope (SEM). The content of norvancomycin in microspheres and the release rate of the norvancomycin in norvancomycin-bonded polypropylene mesh were detected using high performance l iquid chromatography method. The rat models of incisional hernia were developed in 40 healthy Sprague Dawley rats, aged 10-11 weeks and weighing 200-250 g. The rats were divided randomly into the experimental group (norvancomycin-bonded polypropylene mesh repair, n=20) and the control group (polypropylene mesh repair, n=20). And then the mesh was contaminated with Staphylococcus aureus. The wound heal ing was observed after operation. At 3 weeks after operation, the mesh and the tissue around the mesh were harvested to perform histological observation and to classify the inflammatory reaction degree. Results The norvancomycin microsphere had integrated appearance and smooth surface with uniform particle diameter, 64% of particlediameter at 60 to 100 μm, and the loading-capacity of norvancomycin was 19.79%. The norvancomycin-bonded polypropylene patch had well-distributed surface and the loading-capacity of norvancomycin was (7.90 ± 0.85) mg/cm2. The release time of norvancomycin in vitro could last above 28 days and the accumulative release rate was 72.6%. The rats of 2 groups all survived to experiment completion. Wound infection occurred in 2 rats of the experimental group (10%) and 20 rats of the control group (100%), showing significant difference (χ2=32.727 3, P=0.000 0). The inflammatory reaction in experimental group was not obvious, grade I in 16 rats and grade II in 4 rats, and numerous inflammatory cell infiltration occurred in the control group, grade II in 3 rats and grade III in 17 rats, showing significant difference (Z=32.314, P=0.000). Conclusion The polypropylene mesh bonded norvancomycin slow-release microsphere has definite anti-infection effect in rat model of incisional hernia repair contaminated by Staphylococcus aureus.

    Release date:2016-08-31 05:44 Export PDF Favorites Scan
  • A NEW METHOD FOR REPAIR OF HUGE INCISIONAL HERNIA OF ABDOMINAL WALL

    OBJECTIVE To repair the huge incisional hernia of abdominal wall, a new surgical method was introduced. METHODS Eight cases of huge ventral incisional hernia, developed in 3 months to 12 months after operation, were treated in this new method with the defects ranged from 8 cm x 4 cm to 12 cm x 6 cm. RESULTS They were followed up for 6 months to 18 months after operation. The clinical results showed that all of the 8 cases recovered satisfactorily without recurrence. CONCLUSION The new method was recommendable for its advantages of easier manipulation, shortened time, no tissue reaction and less tissue trauma from operation.

    Release date:2016-09-01 11:04 Export PDF Favorites Scan
  • REPAIR OF HUGE INCISIONAL HERNIA OF AB DOMINAL WALL WITH SOFT—TISSUE—CUTA NEOUS FLAP ADJACENT TO HERNIA

    The soft-tissue-cutaneous flap adjacent to the abdominal incisional hernia was ultilized to repair huge hernia in 6 cases with success. Patients were followed up for 2y7 years without recurrence. The operative planning, the technique and the matters needing attention were introduced in details. The soft tissues and skin adjacent to hernia used for repair was easy to obtain and a simple technique. The adoption of this operation in hospitals at the grassroots level was feasible.

    Release date:2016-09-01 11:34 Export PDF Favorites Scan
  • Reoperation of Recurrent Incisional Hernia after Mesh Repair with Prosthetic Patch

    Objective To summarize the experiences and methods on reoperation of recurrent incisional hernia after mesh repair with prosthetic patch. Methods Sixteen patients who got reoperation from January 2007 to December 2010 because of recurrent incisional hernia after mesh repair were analyzed retrospectively. Results All patients received prosthetic patch repair for reoperation. Thirteen patients received new mesh repair accompanied with old mesh removal, repair conducted by suturing new mesh with old mesh together in two patients, and repair performed by new mesh overlapping the old mesh in one patient. All patients recovered with primary wound healing. Fluid upon the mesh occurred in 3 patients and cured by percutaneous puncture and pressure dressing. Postoperative hospital stay was 7 to 16 days and the average 9 days. The drainage was removed 2 to 7 days after operation and the average was 4 days. All the 16 patients were followed up. And during a follow-up range of 5 to 36 months and the average 20 months, there was slight foreign body sensation in one patient, no chronic pain in wound area occurred. And no abdominal wall hernia recurrence occurred. Conclusions Reoperation of recurrent incisional hernia after mesh repair need to consider the recurrent position, material of the previous mesh, and the previous surgical methods, and should select appropriate prosthetic patch and surgical procedure, then could gain satisfied results.

    Release date:2016-09-08 10:36 Export PDF Favorites Scan
  • Analysis on Curative Effect of Laparoscopic Repair for Suprapubic Incisional Hernia Using Composite Patch

    Objective To summarize the surgical technique and curative effect of laparoscopic repair for suprapubic incisional hernia using composite patch. Methods The clinical data of 25 cases performed laparoscopic repair of suprapubic incisional hernia using composite patch from March 2007 to October 2010 were reviewed retrospectively. There were 13 males and 12 females, and aged 35-83 years (median age was 52 years). Among them 2 patients were recurrences. The distance between the lower margin of hernia defect and pubic arc was less than 5 cm. The composite patch was fixed to the abdominal wall using spiral tacks (Protack) in direct vision. The lower margin of the patch was lower to the pubic arc in 2 cm, and to be fixed to the pubic arc and bilateral pectineal ligament, and it should be extended. Results Laparoscopic repair were successfully performed in all patients without convert to open repair. The max diameter of the hernia ring was 6.1-12.5cm and the average was 9.5 cm. The average operating time was 128 min (ranging from 90 to 180 min). And the total complication rate was 28% (7/25), including bladder damage during operation in 1 case, wound seroma upon the patch in 4 cases and cured by aspiration, pain in the operative area and disappeared within one month without intervention in 1 case. Twenty-two patients were followed-up with a follow-up rate of 88%. During a follow-up range of 6-48 months(average 30 months), one case recurrence occurred in 2 months after the repair with the recurrent rate of 4%. Conclusions Laparoscopic repair of suprapubic incisional hernia is a safe and feasible technique, and the patch should cover and exceed the margin of the defect for 5 cm in all direction. The lower margin of the patch should be fixed to the bilateral pectineal ligament so as to strengthen the fix, and lower the recurrence rate.

    Release date:2016-09-08 10:37 Export PDF Favorites Scan
  • Clinical Analysis of Laparoscopic Repair for Abdominal Giant Incisional Hernia

    Objective To study the clinical effect of laparoscopic repair of abdominal incision hernia. Methods The clinical data of 41 abdominal incision hernia patients undergone laparoscopic repair were retrospectively analyzed. Results 〗The operation was successfully performed for 38 cases, and 3 cases were conversed to open. Operative time ranged from 78 to 186 minutes, with an average of 95 minutes. Pain was minor after operation. The first flatus and defecation ranged from 25 to 41 hours, with an average of 32 hours. Food intake started on day 2 after operation. The average length of hospitalization was 6 days (range 5-7 days). After a mean follow-up of 9 (6-16) months, no incision hernia occurred. Conclusion 〗Laparoscopic abdominal incision repair with composite patch is a safe and effective method, which is worthy of clinical application.

    Release date:2016-09-08 10:57 Export PDF Favorites Scan
  • Investigation on Surgical Treatment of Abdominal Incisional Hernia(Analysis for 78 Cases)

    Objective To review the clinical operation methods of abdominal incisional hernia. Methods Classification, operation method and fellow-up of 78 patients with abdominal incisional hernia were retrospectively analyzed. Results The average time of fellow-up was 26 months. Nineteen cases were repaired with simple suture with 3 cases (15.8%) recurrence, 57 cases were repaired with man-made material with 2 case (3.4%) recurrence. Conclusions Individual operation method should be chosen according to body condition, classification of the size of abdominal loss and abdominal hypertension. It is an effective method to repair the hernia of abdominal incision with man-made material.

    Release date:2016-09-08 11:04 Export PDF Favorites Scan
  • Multivariate Analysis of Recurrence of Incisinonal Hernia Following Incisional Hernia Tension-Free Repair

    ObjectiveTo explore the risk factors of recurrence of incisional hernia following incisional hernia tension-free repair. MethodsThe clinical data of 162 patients with incisional hernia underwent tension-free repair were retrospectively analyzed in this hospital from January 2005 to January 2011. The relationships of incisional hernia recur-rence to gender, age, body mass index, hernia size, abdominal wall defect site, preoperative chronic comorbidities, type of tension-free repair, operation time, and wound healing disorders were analyzed by univariate and multivariate analysis. ResultsOne hundred and sixty-two patients were followed up 7-70 months with mean 34.5 months. The rate of recur-rence following incisional hernia tension-free repair was 9.26% (15/162). The results of univariate analysis showed that recurrence following incisional hernia tension-free repair was associated with the age (P < 0.05), body mass index (P < 0.05), type of tension-free repair (P < 0.05), hernia size (P < 0.05), and wound healing disorders (P < 0.05). The results of multivariate logistic regression revealed that the body mass index, type of tension-free repair, hernia size, and wound healing disorders were the independent risk factors associated with recurrence following incisional hernia tension-free repair. Fifteen recurrent patients were reperformed successfully. There was no recurrence following up with an average 23 months. ConclusionsIt is necessary to become familiar with the risk factors for recurrence of incisional hernia in order to eliminate or decrease their effects on the positive outcome of incisional herniorrhaphy. The patients with fat, hernia ring bigger, incorrect opera-tion or wound healing disorders might be easy to relapse. Surgical approach should be individualized for recurrence.

    Release date: Export PDF Favorites Scan
  • Efficacy comparison between ProGrip self-gripping mesh and polypropylene mesh for retromuscular repair of incisional hernias

    Objective To compare the efficacy of retromuscular repair of incisional hernia by using ProGrip self-gripping mesh and conventional polypropylene mesh. Methods A retrospective analysis was made on clinical data of 83 cases of incisional hernia between May 2012 and May 2016. Of 83 cases, ProGrip self-gripping mesh was used in 46 cases (self-gripping mesh group) and conventional polypropylene mesh (conventional mesh group) in 37 cases. There was no significant difference in gender, age, body mass index, types of incision hernia, hernia ring diameter, course of disease, and associated disease between 2 groups (P>0.05). The operative time, hospital stays, and visual analogue scale (VAS) were recorded and compared between 2 groups. Results The self-gripping mesh group was significantly lower than conventional mesh group in operative time and hospital stays (t=2.977,P=0.004;t=2.270,P=0.026). Primary healing of incision was obtained in 2 groups, with no seroma and mesh infection. The VAS score of self-gripping mesh group was significantly lower than that of conventional mesh group at 24 hours, 7 days, and 30 days after operation (P<0.05). The follow-up time was 5-53 months (mean, 25.8 months) in 43 patients of self-gripping mesh group, and was 7-54 months (mean, 27.4 months) in 33 patients of conventional mesh group. No chronic pain or hernia recurrence was found in both groups during follow-up time. Conclusion It is a safe and feasible curative way to use ProGrip self-gripping mesh for retromuscular repair of incisional hernia as it can reduce operative time, hospital stays, and postoperative pain.

    Release date:2017-04-01 08:56 Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content