west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "Intervertebral fusion" 6 results
  • CONTRASTIVE ANALYSIS OF NECK AXIAL SYMPTOMS AFTER HYBRID SURGERY OR TRADITIONAL ANTERIOR CERVICAL DISCECTOMY AND FUSION FOR TREATMENT OF TWO-LEVEL CERVICAL DISEASE

    Objective To explore the occurrence condition of the neck axial symptom (AS) after cervical Bryan artificial disc replacement combined with anterior cervical discectomy and fusion (Hybrid surgery) and traditional anterior cervical discectomy and fusion (ACDF surgery) to treat the two-level cervical disease, and to do contrastive analysis. Methods Between August 2006 and March 2010, 18 patients underwent Hybrid surgery (group A) and 30 patients underwent two-level ACDF surgery (group B). There was no significant difference in age, gender, disease duration, type, and operated segment between 2 groups (P gt; 0.05). The Japanese Orthopaedic Association (JOA) score, neck disability index (NDI) score, cervical curvature of the operated segment, total range of motion (ROM) of C2-7, ROM of the adjacent segment, and incidence of neck AS were recorded and compared between before operation and at last follow-up. Results All the patients were followed up 18-34 months (24.1 months on average). In both groups, the JOA and NDI scores at last follow-up had significantly improvement when compared with preoperative scores (P lt; 0.01), but there was no significant difference between 2 groups at preoperation and last follow-up (P gt; 0.05). The kyphosis incidence of the operated segment in group B was significantly higher than that in group A (χ2=5.333, P=0.021). There was no significant difference in the total ROM of C2-7 between at preoperation and last follow-up in group A (t=0.410, P=0.685); the total ROM of C2-7 at last follow-up was significantly lower than that at preoperation in group B (t=3.007, P=0.006); and significant difference was found between 2 groups at last follow-up (t=2.664, P=0.013). At last follow-up, ROM of the superior and inferior adjacent segments in group B increased obviously (P lt; 0.05) and was significantly higher than that in group A (t=2.252, P=0.033; t=2.203, P=0.037). The incidence of neck AS were 16.7% in group A and 46.7% in group B, showing significant difference at last follow-up (χ2=4.427, P=0.035). Conclusion Compared with two-level ACDF surgery, Hybrid surgery has good outcomes. At the same time, it can maintain the curvature of operated segments and total ROM, avoid excessive increased ROM of the adjacent segments, and reduce the incidence of neck AS.

    Release date:2016-08-31 04:05 Export PDF Favorites Scan
  • BIOMECHANICAL RESEARCH ON MORPHOMETRIC CHANGES IN ADJACENT INFERIOR CERVICAL INTERVERTEBRAL FORAMEN AFTER ARTIFICIAL DISC REPLACEMENT

    Objective To explore changes in the height and width of the cervical intervertebral foramina of C6,7 before and after the C5,6 discetomy, the replacement or the anterior intervertebral fusion so as to provide the theoretical basis for the clinical practice. Methods Eleven fresh cervical spinal specimenswere obtained from young adult cadavers. The specimens of C5,6 were divided into the integrity group, the discectomy group, the artificial disc replacement group, and the intervertebral fusion group. The range of variety (ROV) of the C6,7 intervertebral foramen dimensions (height, width) before and after the loading tests (0.75, 1.50 Nm) were measured in the 4 groups. Results The C6,7 intervetebral foramen height and width increased significantly during flexion (Plt;0.01) but decreased significantly during extension (Plt;0.01). There was a significantdifference between the two test conditions in each of the 4 groups (Plt;0.01). However, in the two test conditions there was no significant difference in ROV of the C6,7 intervetebral foramen height and width during flexion and extension betweenthe integrity group, the discectomy, and the artificial disc replacement group(Pgt;0.05), but a significant difference in the above changes existed in the intervertebral fusion group when compared with the other 3 groups (Plt;0.05). In the same group and under the same conditions, the ROV of the C6,7 intervetebral foramen height and width was significantly different in the two test conditions (Plt;0.01). Conclusion The results have indicated thatartificial disc replacement can meet the requirements of the normal cervical vitodynamics. The adjacent inferior cervical intervetebral foramen increases during flexion but decreases during extension. The intervertebral fusion is probably one of the causes for the cervical degeneration or the accelerated degeneration and for the cervical spondylotic radiculopathy and the brachial plexus compression.

    Release date:2016-09-01 09:20 Export PDF Favorites Scan
  • TREATMENT OF LUMBAR SPONDYLOLISTHESIS WITH AF DEVICE FIXATION SYSTEM AND PROSPACE INTERBODY FUSION CAGE

    BJECTIVE: To discuss the clinical effect and the application of AF device fixation system and PROSPACE interbody fusion cage on treating lumbar spondylolisthesis. METHODS: Twenty-one cases of lumbar spondylolisthesis treated by operation from 1999 to 2002 were analyzed retrospectively (13 males and 8 females, 25-66 years old averaging 42 years). We had thorough decompression on the part of nerve compression and had replacement and fixation of the slippage vertebral body with the AF transpedicular screw/rod system so that the normal spine physiological curvature could be recovered, and then performed the posterolateral interbody fusion with implanting the PROSPACE filled with autograft bones. RESULTS: All the patients were followed up for 3 months to 3 years with an average of 15 months. The preoperation symptoms improved in 20 cases (95.2%). CONCLUSION: The combination of AF device fixation system and PROSPACE interbody fusion cage can relieve effectively nerve compression, recover the normal spinal physiological curvature, maintain the height of interbody and promote the nerve fusion. It is reliable and effective in the treatment of spondylolisthesis.

    Release date:2016-09-01 09:35 Export PDF Favorites Scan
  • SURGICAL TREATMENT OF LUMBAR SPONDYLOLISTHESIS WITH CAGES AND TRANSPEDICAL SCREWS

    Objective To observe the effect of threaded titanium cage and transpedical screw for the treatment of lumbar spondylolisthesis. Methods Eighteen patients with lumbar spondylolisthesis were adopted in this study. Among them, there were 8 males and 10 females, aged from 43 to 62 years old .Roentgenogramshowed that there were 6 cases of Ⅰ° spondylolisthesis, 11 cases of Ⅱ° and 1 case of Ⅲ°. All patients were treated with cages for intervertebral fusion after total laminectomy and pedicle screws for the reduction. Results The cases were followed up from 6 to 12 months with an average of 11 months. The clinical results were excellent in 13 cases and good in 5 cases. All patients achieved successful fusion and bony union . There were no pedicle screw loosening or broken or peripheral nerve dysfunction in this series. Conclusion This method has been proved to be an effective and reliable procedure for treatment of lumbar spondylolithesis. It produces a high fusion rate and clinical success.

    Release date: Export PDF Favorites Scan
  • EXPERIMENTAL STUDY ON APPLICATION OF ALLOGENEIC BONE MATRIX GELATIN IN THE INTERVERTEBRAL FUSION

    OBJECTIVE To testify the inductive osteogenesis of allogeneic bone matrix gelatin (BMG) in promoting intervertebral fusion. METHODS The gelatin sponge, allogeneic BMG, decalcified bone matrix (DBM) and alcohol conserved bone were implanted respectively into the intervertebral space of rabbit, whose intervertebral discs were removed before implantation. The intervertebral spaces were evaluated by X-ray and histological examination at 4, 8, and 12 weeks after operation. RESULTS No obvious immune rejection was observed. Amounts of new bone were formed in the intervertebral spaces at 4 and 8 weeks. And complete infusion of the intervertebral spaces were appeared at 12 weeks. CONCLUSION Allogeneic BMG can promote bone fusion of intervertebral spaces through osteoinduction, which suggests that allogeneic BMP is an ideal substitute for bone replacement.

    Release date:2016-09-01 10:25 Export PDF Favorites Scan
  • Research progress of three-dimensional printing technology for clinical application in intervertebral fusion region

    With the development of three-dimensional (3D) printing technology, more and more researches have focused on its application in the region of intervertebral fusion materials; the prospects are worth looking forward to. This article reviews the researches about 3D printing technology in spinal implants, and summarizes the materials and printing technology applied in the field of spinal interbody fusion, and the shortcomings in the current research and application. With the rapid development of 3D printing technology and new materials, more and more 3D printing spinal interbodies will be developed and used clinically.

    Release date:2018-09-25 02:22 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content