Abstract: Objective To analyze clinical outcomes of intra-aortic balloon pump (IABP) application for high-risk patients before undergoing off-pump coronary artery bypass grafting (OPCAB), and summarize our experience and weaning indications of IABP. Methods We retrospectively analyzed clinical data of 102 high-risk patients with coronary artery disease who underwent IABP implantation before OPCAB from January 2008 to July 2011 in Zhongshan Hospital of Fudan University. There were 71 male patients and 31 female patients with their average age of 63.0±8.2 years in this IABP group. We also chose another 100 patients without IABP implantation before undergoing OPCAB as the control group, including 55 male patients and 45 female patients with their average age of 64.1±9.5 years. Postoperative systolic arterial blood pressure (SABP), mean arterial blood pressure (MABP), mechanical ventilation time, length of intensive care unit(ICU) stay, morbidity, duration of IABP treatment and in-hospital mortality of two groups were compared. Left ventricular ejection fraction (LVEF) was evaluated with echocardiography 3 months after surgery. Results Postoperative SABP (95.3±12.2 mm Hg vs. 80.1±11.7 mm Hg;t=8.440, P=0.000) and MABP (78.9±13.5 mm Hg vs. 52.3±15.1 mm Hg; t=12.410, P=0.000) of the IABP group were significantly higher than those of the control group. Mechanical ventilation time, length of ICU stay and duration of inotropic support of the IABP group were significantly shorter than those of the control group. The incidence of ventricular arrhythmia, low cardiac output syndrome, perioperative myocardial infarction and dialysis-requiring acute kidney failure of the IABP group were significantly lower than those of the control group. In-hospital mortality of the IABP group was significantly lower than that of the control group [5.9% (6/102) vs. 17.0% (17/100), χ 2 =6.180, P=0.020]. Ninety-six patients in the IABP group and 83 patients in the control group were followed up for 3 months. Three months after surgery, echocardiography showed that LVEF of the IABP group was significantly higher than that of the control group(45.3%±12.0% vs. 39.1%±8.2%, t=3.950, P=0.000). Conclusion Preoperative prophylactic IABP implantation and optimal timing of weaning from IABP support can not only significantly reduce surgical risk and improve surgical outcomes and postoperative recovery of high-risk patients undergoing OPCAB, but also considerably ameliorate patient heart function and reduce perioperative morbidity and mortality.
Abstract: Objective To estimate the effectiveness and safety of intra-aortic balloon pump (IABP)in the patients with mild or mild to moderate aortic regurgitation. Methods A total of 15 patients with mild or mild to moderate aortic regurgitation and low left ventricular ejection fraction (LVEF< 40.00%) including 11 males and 4 females, who underwent IABP application after cardiac surgery between September 2006 and January 2011, were included in this study. Their age ranged from 50 to 74 years with an average age of 63.60 years. There were 9 patients with mild aortic regurgitation and 6 patients with mild to moderate aortic regurgitation, all with LVEF < 40.00%. IABP catheters were inserted before operation and IABP worked after heart the recovery of heart beat. Mean aortic pressure (MAP), cardiac index (CI), systemic vascular resistance index (SVRI), pulmonary vascular resistance index (PVRI), LVEF , and aortic regurgitation volume before the use of IABP and after stopping use of it were compared. Results The total mortality was zero. The patients’ CI significantly improved from 1.99±0.23 L/(min.m2) to 3.30±0.29 L/(min.m2) after IABP (t =48.30,P=0.00). Their LVEFs were significantly improved after use of IABP (37.20%±1.37% versus 42.60%±2.87%, t =11.34,P=0.00). Their SVRI improved significantly (2 347.00±190.00 dyn·s/(cm5·m2) versus 2 128.00±204.00 dyn·s/(cm5 · m2),t=20.60, P=0.00)after use of IABP. However, their aortic regurgitation volume were not significantly increased(χ2=0.60, P=0.44). Conclusion Application of IABP in patients with mild or mild to moderate aortic regurgitation and low LVEF can obtain good circulation support after operation without increasing their aortic regurgitation.
ObjectiveTo summarize the experience of intra-aortic balloon pump (IABP) application on coronary artery bypass grafting(CABG)during perioperative period. MethodsWe retrospectively analyzed the data of 82 patients undergoing simple CABG operation in Wuhan Asia Heart Hospital between January 2011 and December 2013. There were 50 male and 32 female patients at age of 49-75 (63.6±11.5) years. The patients were divided into three groups including a group A (12 patients, preoperative-placed IABP), a group B(39 patients , postoperative active placed IABP), and a group C (31 patients, postoperative passive placed IABP). The clinical effects of the three groups were compared. ResultsThere were significantly statistic differences in sequential organ failure assessment (SOFA) score after postoperative 48 hours, ventilator supporting time, IABP supporting time, catecholamine drug usage time, infection incidence, incidence of ventricular arrhythmia, ICU retention time, postoperative hospital stay, CBP usage rate, and postoperative mortality (P<0.05) among the three groups with worse effect in the group C. ConclusionTaking IABP support during CABG perioperative period is an effective treatment. Preventively preoperative and actively postoperative placing IABP can improve the treatment effects significantly. Therefore, patients should apply CABG as soon as possible without hesitation when IABP indications occur.
ObjectiveTo systematically review the efficacy and safety of prophylactic use of intra-aortic balloon pump counterpulsation (IABP) before coronary artery bypass grafting (CABG) in high risk patients. MethodsDatabases including The Cochrane Library (Issue 2, 2014), PubMed, EMbase, CBM, CNKI, WanFang Data and VIP were electronically searched from inception to July 2014, to collect randomized controlled trials (RCTs) and cohort studies about prophylactic use of IABP before CABG in high risk patients. Two reviewers independently screened literature, extracted data and assessed the risk of bias of included studies. Then, meta-analysis was performed by using RevMan 5.2 software. ResultsA total of 6 RCTs and 6 cohort studies involving 1 359 patients were included, of which 633 prophylactically used IABP before CABG (the IABP group) and 736 didn't prophylactically use IABP before CABG (the control group). The results of meta-analysis showed that: compared with the control group, prophylactic use of IABP could significantly reduce perioperative mortality (RCT: OR=0.15, 95%CI 0.06 to 0.38, P<0.000 1; cohort study: OR=0.36, 95%CI 0.19 to 0.67, P=0.001) and postoperative LCOS (RCT: OR=0.23, 95%CI 0.12 to 0.43, P<0.000 01; cohort study: OR=0.21, 95%CI 0.10 to 0.43, P<0.000 1); there was no significant difference between two groups in incidence rate of postoperative myocardial infarction (MI) (RCT: OR=0.34, 95%CI 0.10 to 1.11, P=0.07; cohort study: OR=0.56, 95%CI 0.26 to 1.24, P=0.15); the results of combined analyses of RCTs showed that, prophylactic use of IABP could significantly reduce postoperative ICU stay (MD=-42.94, 95%CI -56.11 to -29.76, P<0.000 01) and postoperative hospital stay (MD=-3.83, 95%CI-5.82 to -1.85, P=0.0002), but these differences were not found in the results of combined analyses of cohort studies (MD=-4.68, 95%CI 20.69 to 11.33, P=0.57; MD=-0.77, 95%CI -1.80 to 0.26, P=0.14). ConclusionProphylactic use of IABP before CABG in high risk patients can significantly reduce the perioperative mortality, postoperative LCOS and the length of ICU stay, however it cannot reduce postoperative MI. Due to the limited quantity and quality of included studies, the above conclusions still need to be verified by more high quality studies.
Objective To investigate the changes of hemodynamics in patients weaning intra-aortic balloon pump (IABP) by using progressive volume deflation followed by rate reduction. Methods We retrospectively analyzed the clinical data of 36 patients aged 68.9±4.7 years, 22 males and 14 females, who underwent progressive volume deflation followed by rate reduction for IABP weaning in Xinhua Hospital between September 2006 and January 2016. Progressive volume deflation followed by rate reduction was used to wean IABP and collect hemodynamics parameters of each time point. Results All the patients successfully weaned IABP. One patient got re-IABP assistant 36 hours after the first successful weaning. One early death and three patients (8%) with postoperative IABP-related complications were embolization of the toe artery. One was in ipsilateral limb, and two of contralateral limb. One patient with acute hepatic insufficiency and one patient with acute renal insufficiency cured after treatment. Conclusion Intra-aortic balloon pump weaning is successful by using volume deflation followed by rate reduction which allowed better hemodynamic parameters.