find Author "KONG Xiangpeng" 10 results
  • Opioids in primary total joint arthroplasty: Interpretation of 2020 AAHKS/ASRA/AAOS/THS/TKS clinical practice guidelines

    In 2020, the American Association of Hip and Knee Surgeons (AAHKS), the American Society of Regional Anesthesia and Pain Medicine (ASRA), the American Academy of Orthopaedic Surgeons (AAOS), the American Hip Society (THS), the American Knee Society (TKS) have worked together to develop clinical practice guidelines on the use of Opioids in primary total joint arthroplasty (TJA). This clinical practice guideline formulates recommendations for common and important questions related to the efficacy and safety of Opioids in primary TJA. This article interprets the guideline to help doctors make clinical decisions.

    Release date: Export PDF Favorites Scan
  • Application of quadriceps snip in complex total knee arthroplasty

    ObjectiveTo explore the safety and effectiveness of quadriceps snip in complex total knee arthroplasty (TKA).MethodsA clinical data of 19 cases (29 knees) with complex TKA assisted with quadriceps snip between January 2016 and May 2017 were retrospectively analyzed. There were 9 males (13 knees) and 10 females (16 knees). The age of patients ranged from 34 to 66 years (mean, 50.2 years). Four patients (8 knees) were ankylosing spondylitis, 5 patients (7 knees) were rheumatoid arthritis, and 10 patients (14 knees) were knee osteoarthritis. The average disease duration was 10.9 years (range, 8-15 years). There were 12 knees of Kellgren-Lawrence grade Ⅲ and 17 knees of Kellgren-Lawrence grade Ⅳ. The range of motion (ROM) of knee was (19.86±7.23)°. The clinical and function scores of knee society score (KSS) were 47.86±11.26 and 15.52±11.21, respectively. Postoperative complications, ROM, KSS scores, extensor lag, and prosthesis loosening were observed to evaluate the effectiveness.ResultsAll incisions healed by first intention, and no infection or cardiovascular and cerebrovascular accidents occurred. All patients were followed up 25-39 months (mean, 30.3 months). At last follow-up, the ROM of knee was (91.03±7.30) °, the KSS clinical score was 83.62±9.99 and functional score was 66.38±7.89, showing significant differences when compared with preoperative ones (P<0.05). Postoperative extensor lag (10°, 10°, 15°) occurred in 3 cases. There was no evidence of prosthesis loosening or osteolysis on X-ray films during follow-up.ConclusionThe application of quadriceps snip in complex TKA can effectively improve the operative field exposure and reduce incidence of complications such as patella tendon tearing, patella fracture, and quadriceps tendon injury. The surgical technique of Krackow tendon suture can effectively guarantee early rehabilitation without occurrence of other complications.

    Release date:2020-09-28 02:45 Export PDF Favorites Scan
  • A study of low back pain and changes in spinal sagittal parameters after total hip arthroplasty in patients with unilateral Crowe type Ⅳ developmental dysplasia of the hip

    Objective To investigate the changes of low back pain (LBP) and spinal sagittal parameters in patients with unilateral Crowe type Ⅳ developmental dysplasia of the hip (DDH) after total hip arthroplasty (THA). Methods The clinical data of 30 patients who met the selection criteria between October 2018 and March 2020 were retrospectively analyzed. Patients were divided into LBP group (16 cases) and control group (14 cases) according to whether there was LBP before operation. There was no significant difference between the two groups of patients in gender, age, body mass index, affected sides, preoperative Harris score (P>0.05). Full-length lateral X-ray films of the spine were taken within 1 week before operation and at 1 year after operation, and the following imaging indicators were measured: sacral slope (SS), lumbar lordosis (LL ), spinal tilt (ST), spine-sacral angle (SSA), sagittal vertebral axis (SVA). The visual analogue scale (VAS) score, lumbar Oswestry disability index (ODI), the Harris score of the hip joint before operation and at 1 year after operation, and the occurrence of postoperative complications were collected and analysed. Results In the LBP group, LBP was relieved to varying degrees at 1 year after operation, of which 13 patients (81.3%) had complete LBP remission; VAS score decreased from 4.9±2.3 preoperatively to 0.3±0.8, ODI decreased from 33.5±22.6 preoperatively to 1.3±2.9, the differences were all significant (t=7.372, P=0.000; t=5.499, P=0.000). There was no new chronic LBP in the control group during follow-up. The Harris scores of the two groups significantly improved when compared with those before operation (P<0.05); there was no significant difference between the two groups at 1 year after operation (t=0.421, P=0.677). There was no significant difference in imaging indexes between the two groups before operation and the difference between pre- and post-operation (P>0.05). At 1 year after operation, ST and SVA in the LBP group, SSA in the control group, and SS in the two groups significantly improved when compared with those before operation (P<0.05); there was no significant difference in the other indexes between the two groups before and after operation (P>0.05). Conclusion Unilateral Crowe type Ⅳ DDH patients with LBP before operation were all relieved of LBP after THA. The relief of LBP may be related to the improvement of spinal balance, but not to lumbar lordosis and its changes.

    Release date: Export PDF Favorites Scan
  • Effect of accuracy of phase 3 Oxford prosthesis positioning on short-term effectiveness of unicompartmental knee arthroplasty

    Objective To investigate the effect of accuracy of phase 3 Oxford prosthesis positioning on short-term effectiveness of unicompartmental knee arthroplasty (UKA). Methods The clinical data of 26 patients (26 knees) who were treated with UKA between September 2015 and November 2015 was retrospectively analyzed. The single-peg Oxford prosthesis was implanted in 15 patients (single-peg group), and twin-peg Oxford prosthesis was implanted in 11 patients (twin-peg group). There was no significant difference in gender, age, body mass index, Kellgren-Lawrence grading, and preoperative Hospital for Special Surgery (HSS) scores between 2 groups (P>0.05). HSS, knee society score (KSS), Western Ontario and McMaster University Osteoarthritis Index (WOMAC), and Oxford knee score (OKS) were used to evaluate the knee function. Radiographic criteria for Oxford UKA was used to evaluate the prosthesis position. The reason and treatment of bearing dislocations were recorded. Results All patients were followed up with mean follow-up time of 26.2 months in single-peg group (range, 24-27 months) and 25.2 months in twin-peg group (range, 24-26 months). The bearing dislocation occurred in 2 cases of twin-peg group during follow-up. At last follow-up, there was no significant difference in HSS, WOMAC, OKS, and KSS scores between 2 groups (P>0.05). There was no significant difference in radiographic scores of femoral component, tibial component, and overall components between 2 groups (P>0.05). No significant correlation was found between radiographic scores and postoperative functional outcome in 2 groups (P>0.05). Conclusion Within a safe range, the accuracy of phase 3 Oxford prosthesis positioning has limited influence on the short-term functional outcome.

    Release date:2018-12-04 03:41 Export PDF Favorites Scan
  • Research progress in unicompartmental knee arthroplasty

    ObjectiveTo summarize the clinical application and research progress in unicompartmental knee arthroplasty (UKA).MethodsThe literature related to UKA in recent years was reviewed and the emerging indications, implant options, comparisons between other surgical techniques, and recent advances were summarized.ResultsClinical studies show that UKA has many advantages, such as less trauma, faster recovery, and fewer postoperative complications. At present, the operative indication has been expanded. The body mass index more than 25 kg/m2, less than 60 years old, patellofemoral arthritis, and anterior cruciate ligament dysfunction are no longer considered as contraindications. The prosthesis type in UKA should be selected according to the patient’s condition. In recent years, the robot-assisted UKA can effectively improve the effectiveness, improve patient satisfaction, and reduce postoperative complications.ConclusionWith the development of surgical techniques, designs of prosthesis, and the robotic technology, UKA would be further applicated. As more long-term data on UKA become available, it will further guide clinicians in counseling patients on whether UKA should be performed.

    Release date:2020-02-20 05:18 Export PDF Favorites Scan
  • Application of Mako robot-assisted total hip arthroplasty in developmental dysplasia of the hip

    Objective To evaluate the early effectiveness and summarize the initial application experiences of Mako robot-assisted total hip arthroplasty (THA) for developmental dysplasia of the hip (DDH) in adults. Methods Between August 2018 and January 2020, 55 cases of DDH (75 hips) were treated with Mako robot-assisted THA. There were 10 males and 45 females with an average age of 51 years (range, 30-73 years). There were 35 cases of unilateral hip and 20 cases of bilateral hips. The DDH was classified as Crowe type Ⅰin 29 hips, type Ⅱ in 20 hips, type Ⅲ in 6 hips, and type Ⅳ in 20 hips. The modified Harris score was 54.8±16.0, the hip joint range of motion was 90° (80°, 100°), and the leg length discrepancy (LLD) was 22.0 (10.5, 47.0) mm. The preoperative surgical plan was made in the robot system based on the CT data. The reaming and installation of the acetabular cup were completed with the assistance of the robot system. The distance between the rotation center of the hip joint and the teardrop (horizontal distance, vertical distance), inclination angle, and anteversion angle were measured on the pelvic X-ray film to evaluate the position of the acetabular prosthesis. The above indicators were compared with preoperative planning to evaluate the accuracy of robotic-assisted surgery. The modified Harris score, the range of motion, and the LLD were used to evaluate the early effectiveness. Results The 75 hips of THAs were completed with the assistance of Mako robots. There was no significant difference in the acetabular inclination angle, the horizontal distance and the vertical distance of the rotation center between the preoperative planning and the postoperative measurement values (P>0.05); the acetabular anteversion angle was significantly smaller than the postoperative measurement value (t=–2.482, P=0.015). Four hips located beyond the Lewinnek safety zone, and 71 hips located within the Lewinnek safety zone. All patients followed up 6-24 months (mean, 13 months). All incisions healed by first intention. At last follow-up, the modified Harris score was 85.5±11.2, the hip joint range of motion was 120° (110°, 120°), and the LLD was 3.8 (2.0, 8.1) mm; all improved significantly compared with preoperative ones (P<0.05). Except for one nerve injury case, there was no other complication. Conclusion Mako robot-assisted THA is a safe and effective method for adult DDH, which can optimize the acetabular cup positioning, hip function, and leg length, but the long-term effectiveness needs to be confirmed by further studies.

    Release date: Export PDF Favorites Scan
  • A comparative study of three different fixation methods after subtrochanteric shortening osteotomy in total hip arthroplasty for Crowe type Ⅳ developmental dysplasia of the hip

    ObjectiveTo compare the effectiveness of three different fixation methods after subtrochanteric shortening osteotomy (SSO) in total hip arthroplasty (THA) for Crowe type Ⅳ developmental dysplasia of the hip (DDH). Methods A clinical data of 63 patients (78 hips) with Crowe type Ⅳ DDH, who underwent THA with SSO between November 2014 and May 2019, was retrospectively analyzed. Among them, 18 patients (20 hips) obtained stability by intramedullary pressure provided by the S-ROM modular prostheses (group A); 22 patients (30 hips) underwent prophylactic binding by stainless steel wire after osteotomy and before stem implantation (group B); 23 patients (28 hips) were fixed with autogenous cortical strut grafts and stainless steel wire or cables (group C). There was no significant difference in gender, age, body mass index, affected limb side, and preoperative Harris score between groups (P>0.05). The operation time, complications, imaging results, hip functional score of the three groups were recorded and compared. Results There was no significant difference in the operation time between groups (P>0.05). All incisions healed by first intention. All patients were followed up, and the follow-up time was 2.5-4.0 years (mean, 3.1 years) in group A, 1.5-5.5 years (mean, 3.2 years) in group B, and 1.0-5.0 years (mean, 1.6 years) in group C. There was no significant difference in Harris score or Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score between groups at 4 and 12 months after operation (P>0.05). X-ray films showed that there was no significant difference in osteotomy healing rate at 4, 8, and 12 months after operation and the osteotomy healing time between groups (P>0.05). There was no complications such as joint dislocation, prosthesis loosening, prosthetic joint infection, or heterotopic ossification during follow-up, except for the distal femoral fracture of 1 hip during operation in group B. Conclusion In THA for patients with Crowe type Ⅳ DDH, the stainless steel wire binding alone and autogenous cortical strut grafts combined with stainless steel wire or cable binding can not significantly promote the osteotomy healing compared with femoral prosthesis intramedullary compression fixation. For patients with nonmatched medullary cavity after SSO, it is recommended to apply autogenous cortical strut grafts with wire or cables for additional fixation.

    Release date: Export PDF Favorites Scan
  • Application of preoperative digital-template planning in total hip arthroplasty via direct anterior approach

    ObjectiveTo investigate the accuracy of preoperative digital-template planning in total hip arthroplasty (THA) via direct anterior approach (DAA) and its effect on the short-term effectiveness.MethodsThe clinical data of 77 patients (109 hips) with osteonecrosis of femoral head who underwent THA via DAA between January 2016 and May 2018 was retrospectively analyzed. According to the type of template, patients were divided into digital-template group (group A, 40 patients, 56 hips) and conventional-template group (group B, 37 patients, 53 hips). There was no significant difference in age, gender, body mass index, the stages of osteonecrosis of femoral head, and preoperative Harris hip score (HHS) (P>0.05). The operation time, intraoperative blood loss, frequencies of intraoperative fluoroscopy, and complications were recorded. Otherwise, the consistency rate of preoperative planning and practical prosthesis size was analyzed. Position of acetabular prosthesis and femoral prosthesis alignment were measured on anteroposterior X-ray film of the pelvis at 3 months after operation. HHS was used to evaluate clinical function.ResultsThe consistency rate of preoperative planning and practical acetabular prosthesis size was significantly higher in group A (80.4%, 45/56) than that in group B (62.3%, 33/53), showing significant difference (χ2=4.38, P=0.04). But there was no significant difference in the consistency rate of preoperative planning and practical femoral prosthesis size between group A (83.9%, 47/56) and group B (79.2%, 42/53)(χ2=0.40, P=0.53). The prosthesis abductions were (40.7±6.4)° in group A and (38.8±7.3)° in group B; the femoral prosthesis alignment deviations were (0.1±1.8)° in group A and (0.3±1.7)° in group B. There was no significant difference in the prosthesis abduction and femoral prosthesis alignment deviation between 2 groups (P>0.05). No prosthesis sinking or loosening occurred during follow-up. The operation time and frequencies of intraoperative fluoroscopy were less in group A than those in group B (P<0.05). But there was no significant difference in intraoperative blood loss between 2 groups (t=1.92, P=0.06). The complication occurred in 1 hip of group A and 6 hips of group B, with no significant difference (P=0.06). All patients were followed up 6-22 months (mean 13.8 months) in group A and 6-24 months (mean, 14.6 months) in group B. At last follow-up, the HHS scores were 91.8±3.1 in group A and 92.6±4.2 in group B, and the difference was not significant (t=1.14, P=0.26).ConclusionPreoperative digital-template planning in THA via DAA is accurate, which can reduce the operation time and frequencies of intraoperative fluoroscopy without enhancing the risk of complication.

    Release date:2019-11-21 03:35 Export PDF Favorites Scan
  • Measurement and analysis of leg length in adults with unilateral developmental dysplasia of the hip

    ObjectiveTo measure and analyze the radiographic characteristics of the leg length discrepancy in adult patients with unilateral developmental dysplasia of the hip (DDH).MethodsThe clinical data of 112 patients with unilateral DDH who met the selection criteria between January 2016 and June 2018 were retrospectively analyzed. There were 16 males and 96 females with an age of 20-76 years (mean, 42.9 years). According to the Crowe classification, there were 25 hips of type Ⅰ, 26 hips of type Ⅱ, 15 hips of type Ⅲ, and 46 hips of type Ⅳ (26 hips of type ⅣA without secondary acetabular formation, and 20 hips of type ⅣB with secondary acetabular formation). Full-length X-ray films of the lower limbs in the standing position were used to measure the following parameters: greater trochanter leg length (GTLL), greater trochanter femoral length (GTFL), lesser trochanter leg length (LTLL), lesser trochanter femoral length (LTFL), tibial length (TL), and intertrochanteric distance (ITD). The above parameters on the healthy and affected sides were compared and the difference of each parameter between the healthy and affected sides was calculated. Taking the difference of 5 mm between the healthy side and the affected side as the threshold value, the number of cases with the healthy side was greater than 5 mm and the affected side was greater than 5 mm were counted respectively. The difference of the imaging parameters between the healthy side and the affected side were compared between different Crowe types and between type ⅣA and type ⅣB.ResultsThere was no significant difference in GTLL and LTFL between healthy and affected sides (P>0.05); LTLL and TL of affected side were longer than healthy side, GTFL and ITD were shorter than healthy side, and the differences were significant (P<0.05). The constituent ratio of long cases on the affected side of TL and LTLL was greater than the constituent ratio of long cases on the healthy side, while the constituent ratio of long cases on the healthy side of GTFL and ITD was greater than the constituent ratio of long cases on the affected side; there was no obvious difference in the constituent ratio of long cases on the healthy side or the affected side of GTLL and LTFL. The comparison between different Crowe types showed that only the difference in TL between type Ⅰ and type Ⅳ was significant (P<0.05), the difference of each imaging parameter among the other types showing no significant difference (P>0.05). Compared with type ⅣB, the differences of GTLL, TL, and ITD of type ⅣA were bigger, and the differences were significant (P<0.05); the differences of other parameters between type ⅣA and type ⅣB were not significant (P>0.05).ConclusionIn adult unilateral DDH patients, the leg length on the healthy side and the affected side is different, and the difference mainly comes from the TL and ITD, which should be paid attention to in preoperative planning.

    Release date:2021-06-07 02:00 Export PDF Favorites Scan
  • Study on the accuracy of automatic segmentation of knee CT images based on deep learning

    Objective To develop a neural network architecture based on deep learning to assist knee CT images automatic segmentation, and validate its accuracy. Methods A knee CT scans database was established, and the bony structure was manually annotated. A deep learning neural network architecture was developed independently, and the labeled database was used to train and test the neural network. Metrics of Dice coefficient, average surface distance (ASD), and Hausdorff distance (HD) were calculated to evaluate the accuracy of the neural network. The time of automatic segmentation and manual segmentation was compared. Five orthopedic experts were invited to score the automatic and manual segmentation results using Likert scale and the scores of the two methods were compared. Results The automatic segmentation achieved a high accuracy. The Dice coefficient, ASD, and HD of the femur were 0.953±0.037, (0.076±0.048) mm, and (3.101±0.726) mm, respectively; and those of the tibia were 0.950±0.092, (0.083±0.101) mm, and (2.984±0.740) mm, respectively. The time of automatic segmentation was significantly shorter than that of manual segmentation [(2.46±0.45) minutes vs. (64.73±17.07) minutes; t=36.474, P<0.001). The clinical scores of the femur were 4.3±0.3 in the automatic segmentation group and 4.4±0.2 in the manual segmentation group, and the scores of the tibia were 4.5±0.2 and 4.5±0.3, respectively. There was no significant difference between the two groups (t=1.753, P=0.085; t=0.318, P=0.752). Conclusion The automatic segmentation of knee CT images based on deep learning has high accuracy and can achieve rapid segmentation and three-dimensional reconstruction. This method will promote the development of new technology-assisted techniques in total knee arthroplasty.

    Release date: Export PDF Favorites Scan