west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "LI Yiyang" 5 results
  • Effectiveness of shape memory alloy embracing device in treatment of Vancouver B2 periprosthetic femoral fracture

    Objective To analyze the effectiveness of shape memory alloy embracing device in the treatment of Vancouver B2 periprosthetic femoral fracture after primary hip arthroplasty. Methods The clinical data of 30 patients (30 hips) with Vancouver B2 periprosthetic femoral fracture after primary hip arthroplasty between January 2019 and January 2021 were analyzed retrospectively. Among them, 15 cases were treated with shape memory alloy embracing device for fracture fixation (group A) and 15 cases with titanium cable cerclage (group B). There was no significant difference in general data such as gender, age, body mass index, the cause of primary arthroplasty and surgical method, prosthesis type, the cause and side of femoral fracture, the time from injury to operation, and comorbidities between the two groups (P>0.05). The operation time, intraoperative blood loss, and hospital stay of the two groups were recorded. The fracture healing was examined by X-ray film, and the hip joint function was evaluated by Harris score. Results The operations in both groups were completed successfully, and the incisions healed by first intention after operation with no vascular or nerve injury. The operation time and hospital stay in group A were significantly shorter than those in group B (P<0.05), but there was no significant difference in intraoperative blood loss between group A and group B (t=−0.518, P=0.609). Patients were followed up 12-20 months (mean, 16.3 months) in group A and 12-22 months (mean, 16.7 months) in group B. X-ray film showed that all fractures healed, the healing time was (14.73±2.05) weeks in group A and (17.27±2.60) weeks in group B, and there was a significant difference between the two groups (t=−2.960, P=0.006). During follow-up, there was no complication such as prosthesis loosening, periprosthetic infection, joint stiffness, or internal fixator loosening. The Harris score of group A was significantly better than that of group B at 3, 6, and 12 months after operation (P<0.05). Conclusion Compared with titanium cable cerclage, using shape memory alloy embracing device to fix Vancouver B2 periprosthetic femoral fracture can accelerate fracture healing, shorten operation time, and reduce intraoperative blood loss. Patients can perform functional exercise earlier and restore joint function better.

    Release date: Export PDF Favorites Scan
  • Colon polyp detection based on multi-scale and multi-level feature fusion and lightweight convolutional neural network

    Early diagnosis and treatment of colorectal polyps are crucial for preventing colorectal cancer. This paper proposes a lightweight convolutional neural network for the automatic detection and auxiliary diagnosis of colorectal polyps. Initially, a 53-layer convolutional backbone network is used, incorporating a spatial pyramid pooling module to achieve feature extraction with different receptive field sizes. Subsequently, a feature pyramid network is employed to perform cross-scale fusion of feature maps from the backbone network. A spatial attention module is utilized to enhance the perception of polyp image boundaries and details. Further, a positional pattern attention module is used to automatically mine and integrate key features across different levels of feature maps, achieving rapid, efficient, and accurate automatic detection of colorectal polyps. The proposed model is evaluated on a clinical dataset, achieving an accuracy of 0.9982, recall of 0.9988, F1 score of 0.9984, and mean average precision (mAP) of 0.9953 at an intersection over union (IOU) threshold of 0.5, with a frame rate of 74 frames per second and a parameter count of 9.08 M. Compared to existing mainstream methods, the proposed method is lightweight, has low operating configuration requirements, high detection speed, and high accuracy, making it a feasible technical method and important tool for the early detection and diagnosis of colorectal cancer.

    Release date: Export PDF Favorites Scan
  • Research progress on the design of bone scaffolds with different single cell structures

    Objective To review the research progress of design of bone scaffolds with different single cell structures. Methods The related literature on the study of bone scaffolds with different single cell structures at home and abroad in recent years was extensively reviewed, and the research progress was summarized. ResultsThe single cell structure of bone scaffold can be divided into regular cell structure, irregular cell structure, cell structure designed based on topology optimization theory, and cell structure designed based on triply periodic minimal surface. Different single cell structures have different structural morphology and geometric characteristics, and the selection of single cell structure directly determines the mechanical properties and biological properties of bone scaffold. It is very important to choose a reasonable cell structure for bone scaffold to replace the original bone tissue. Conclusion Bone scaffolds have been widely studied, but there are many kinds of bone scaffolds at present, and the optimization of single cell structure should be considered comprehensively, which is helpful to develop bone scaffolds with excellent performance and provide effective support for bone tissue.

    Release date: Export PDF Favorites Scan
  • Research progress in influence of microstructure on performance of triply-periodic minimal surface bone scaffolds

    Objective To summarize the influence of microstructure on performance of triply-periodic minimal surface (TPMS) bone scaffolds. Methods The relevant literature on the microstructure of TPMS bone scaffolds both domestically and internationally in recent years was widely reviewed, and the research progress in the imfluence of microstructure on the performance of bone scaffolds was summarized. Results The microstructure characteristics of TPMS bone scaffolds, such as pore shape, porosity, pore size, curvature, specific surface area, and tortuosity, exert a profound influence on bone scaffold performance. By finely adjusting the above parameters, it becomes feasible to substantially optimize the structural mechanical characteristics of the scaffold, thereby effectively preempting the occurrence of stress shielding phenomena. Concurrently, the manipulation of these parameters can also optimize the scaffold’s biological performance, facilitating cell adhesion, proliferation, and growth, while facilitating the ingrowth and permeation of bone tissue. Ultimately, the ideal bone fusion results will obtain. Conclusion The microstructure significantly and substantially influences the performance of TPMS bone scaffolds. By deeply exploring the characteristics of these microstructure effects on the performance of bone scaffolds, the design of bone scaffolds can be further optimized to better match specific implantation regions.

    Release date: Export PDF Favorites Scan
  • Melatonin promotes osteogenesis of bone marrow mesenchymal stem cells by improving the inflammatory state in ovariectomized rats

    ObjectiveTo investigate the effects of melatonin (MT) on bone mass and serum inflammatory factors in rats received ovariectomy (OVX) and to investigate the effects of MT on the levels of inflammatory factors in culture medium and osteogenic ability of bone marrow mesenchymal stem cells (BMSCs) stimulated by lipopolysaccharide. Methods Fifteen 12-week-old Sprague Dawley (SD) rats were randomly divided into 3 groups. The rats in Sham group only received bilateral lateral abdominal incision and suture, the rats in OVX group received bilateral OVX, and the rats in OVX+MT group received 100 mg/(kg·d) MT oral intervention after bilateral OVX. After 8 weeks, the levels of serum inflammatory factors [interleukin-1β (IL-1β), IL-6, and tumor necrosis factor α (TNF-α)] were detected using ELISA assay. Besides, the distal femurs were detected by Micro-CT to observe changes in bone mass and microstructure, and quantitatively measured bone volume fraction, trabecular thickness, and trabecular number. The BMSCs were extracted from the femurs of three 3-week-old SD rats using whole bone marrow culture method and passaged. The 3rd-5th passage BMSCs were cultured with different concentrations of MT (0, 1, 10, 100, 1 000 µmol/L), and the cell viability was then detected using cell counting kit 8 (CCK-8) to select the optimal concentration of MT for subsequent experiments. Cells were devided into osteogenic induction group (group A) and osteogenic induction+1/5/10 μg/mL lipopolysaccharide group (group B-D). The levels of inflammatory factors (IL-1β, IL-6 and TNF-α) in cell culture medium were detected using ELISA assay after corresponding intervention. According to the results of CCK-8 method and ELISA detection, the cells were intervened with the most significant concentration of lipopolysaccharide for stimulating inflammation and the optimal concentration of MT with osteogenic induction, defining as group E, and the cell culture medium was collected to detect the levels of inflammatory factors by ELISA assay. After that, alkaline phosphatase (ALP) staining and alizarin red staining were performed respectively in groups A, D, and E, and the expression levels of osteogenic related genes [collagen type Ⅰ alpha 1 chain (Col1a1) and RUNX family transcription factor 2 (Runx2)] were also detected by real time fluorescence quantitative PCR (RT-qPCR). ResultsELISA and Micro-CT assays showed that compared with Sham group, the bone mass of the rats in the OVX group significantly decreased, and the expression levels of serum inflammatory factors (IL-1β, IL-6, and TNF-α) in OVX group significantly increased (P<0.05). Significantly, the above indicators in OVX+MT group were all improved (P<0.05). Rat BMSCs were successfully extracted, and CCK-8 assay showed that 100 µmol/L was the maximum concentration of MT that did not cause a decrease in cell viability, and it was used in subsequent experiments. ELISA assays showed that compared with group A, the expression levels of inflammatory factors (IL-1β, IL-6, and TNF-α) in the cell culture medium of groups B-D were significantly increased after lipopolysaccharide stimulation (P<0.05), and in a concentration-dependent manner. Moreover, the expression levels of inflammatory factors in group D were significantly higher than those in groups B and C (P<0.05). After MT intervention, the expression levels of inflammatory factors in group E were significantly lower than those in group D (P<0.05). ALP staining, alizarin red staining, and RT-qPCR assays showed that compared with group A, the percentage of positive area of ALP and alizarin red and the relative mRNA expressions of Col1a1 and Runx2 in group D significantly decreased, while the above indicators in group E significantly improved after MT intervention (P<0.05). ConclusionMT may affect the bone mass of postmenopausal osteoporosis by reducing inflammation in rats; MT can reduce the inflammation of BMSCs stimulated by lipopolysaccharide and weaken its inhibition of osteogenic differentiation of BMSCs.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content