Objective To investigate the awareness and clinical needs of wearable artificial kidney among maintenance hemodialysis (MHD) patients, and to analyze the related influencing factors. Methods MHD patients were recruited from 2 tertiary hospitals in Sichuan province between April and June 2021. The convenient sampling method was used to select patients. The factors influencing the awareness and demand of MHD patients for wearable artificial kidney were analyzed. Results A total of 119 MHD patients were included. The awareness of wearable artificial kidney among the patients was mainly “never heard” (61 cases) and “heard” (58 cases). Most MHD patients (60 cases) were willing to use and participate in clinical trials in the future. The results of logistic regression indicated that the cost on household economy and treatment effect on life quality were the influencing factors for MHD patients’ awareness of wearable artificial kidney (P<0.05). The average duration of single dialysis and the impact of treatment on working or studying were the influencing factors for MHD patients’ needs of wearable artificial kidney (P<0.05). Conclusions The awareness of wearable artificial kidney is low among MHD patients. However, most MHD patients showed great interest in the wearable artificial kidney after preliminary understanding, suggesting that the future clinical application of wearable artificial kidney has great demand.