west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "LIANG Xi" 3 results
  • LONG PHILOS LOCKING COMPRESSION PLATE FOR TREATMENT OF PROXIMAL HUMERUS AND HUMERAL SHAFT FRACTURES

    Objective To investigate the therapeutic effect of long PHILOS locking compression plate on the proximal humerus and humeral shaft fractures. Methods From March 2005 to December 2007, 35 cases with the proximal humerus and humeral shaft fractures were treated with long PHILOS locking compression plate, including 16 males and 19 females aged 29-68 years old (average 54.5 years old). There were 34 cases of fresh and close fracture, and the time from injury to operation was 3-9 days. One case had delayed union of fracture 5 months after receiving T-plates and internal fixation with steel plate. For the proximal humerus fracture, 7 cases had 2 parts of fracture, 19 had 3 parts of fracture, and 9 had 4 parts of fracture according to Neer classification; while for the humeral shaft fracture, 3 cases were classified as A1, 5 as A2, 10 as B1, 3 as B2, 6 as B3, 7 as C1 and 1 as C3 according to AO classification. Postoperatively, Neer scoring system was employed to evaluate the function of shoulder joint and HSS scoring system was adopted to evaluate the function of elbow joint. Results All incisions healed by first intension, and 30 cases were followed up for 12-33 months (average 18.2 months). Postoperatively, 2 cases had symptoms of radial nerve paralysis, which disappeared within 3 weeks; 1 case suffered from humeral head necrosis and received the secondary operation of humeral head replacement; humeral head was reduced evenly in 1 case, and 2 cases felt chronic sl ight pain in shoulder joints and received no further treatment. X-ray films showed 29 cases had fracture heal ing 6 months after operation, and all the patients had bone union 12 months after operation except 1 case receiving humeral head replacement. No such compl ications as screw lossening and internal fixation loosening occurred. By Neer scoring system, 6 cases were graded as excellent, 19 as good, 3 as fair, 2 as poor, and the excellent and good rate was 83.3%. By HSS scoring system, 16 cases were gradedas excellent, 14 as good, and the excellent and good rate was 100%. Conclusion Applying long PHILOS locking compression plate in the treatment of the proximal humerus and humeral shaft fractures provides a sol id fixation and high satisfactory rate with minor compl ications.

    Release date:2016-09-01 09:05 Export PDF Favorites Scan
  • Anatomical study of anterior cruciate ligament and its effect on reconstruction technique

    Objective To summarize the current research progress of anterior cruciate ligament (ACL) anatomy, and discuss its effect on the reconstruction technique. Methods The literature concerning ACL anatomy and reconstruction at home and abroad was extensively reviewed and summarized. Results The anatomy and morphology of ACL has gained new recognition in recent years, and the " Ribbon-like” ACL has gradually been paid attention to by researchers. In present researches, it seems the " Ribbon-like” anatomy theory has advantages in theory when compared with the previous anatomy theory. It is more in line with the anatomy and isometric reconstruction. Conclusion The understanding of ACL anatomy guided the development of ACL reconstruction. The " Ribbon-like” ACL anatomy theory is the different understanding of the anatomy theory, which remains controversy. The " Ribbon-like” reconstruction maybe has more advantages in theory, but further study is needed.

    Release date:2018-03-07 04:35 Export PDF Favorites Scan
  • Clinical analysis of 31 lung metastases patients by percutaneous thermal ablation in a single center

    ObjectiveTo explore the factors that affect the accuracy of percutaneous thermal ablation of lung metastases and coping strategies.MethodsWe retrospectively analyzed the clinical data of 31 patients who met the conditions for thermal ablation of lung metastases in Ninth People’s Hospital affiliated to Shanghai Jiao Tong University School of Medicine between October 2019 and December 2020. There were 19 males and 12 females with a mean age of 40-81 (62.8±10.3) years. A total of 33 metastases tumors were thermally ablated, 12 were radiofrequency ablation and 19 were microwave ablation.ResultsOf the 33 metastatic tumors, 5 targets showed significant puncture deviation, 4 of them completed the ablation after adjustment and 1 failed. The result of the univariate logistic regression showed the distance within the lung parenchyma (P=0.043) and the maximum diameter of the tumor (P=0.025) were independent risk factors for the accuracy of percutaneous thermal ablation. In terms of correlation, there was a positive correlation between the accuracy of percutaneous thermal ablation and the distance within the lung parenchyma (P=0.033), and a negative correlation between the maximum diameter of metastases tumor (P=0.004) and hemoptysis (P=0.015). Complete ablation rate was 87.8% (29/33).ConclusionWhen we perform CT-guided percutaneous thermal ablation of lung metastases, we must fully prepare the deviation plan for the small diameter tumor, the long travel distance in the lung parenchyma, and hemoptysis during puncture. Complete ablation can be achieved by fully identifying the anatomical features of the tumor and its surrounding structures, shortening the travel distance in the lung parenchyma and increasing the ablation range.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content