west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "LIN Peng" 2 results
  • PRELIMINARY CLINICAL EFFECT OF PROXIMAL FEMORAL NAIL ANTI-ROTATION TO TREAT FEMORALINTERTROCHANTERIC FRACTURES

    Objective To evaluate the primary cl inical effect of proximal femoral nail anti-rotation (PFNAR) in treating femoral intertrochanteric fractures, to summarize operation skills and to analyze correlated curative effective influentialfactors. Methods From July 2006 to May 2007, 19 cases of intertrochanteric fractures (including 8 males, 11 females, aged45-87 years old) were treated with closed reduction and PFNAR fixation. Fractures were caused by fall ing. The locations were left sides in 10 cases and right sides in 9 cases. According to AO classification, there were 14 cases of type A2 and 5 cases of type A3. Operative time, volume of blood loss and weight bear time were analyzed, the condition of fracture union was observed and the hip function was evaluated using Harris criterion after 9 months of follow-up. Results Operative time ranged 23-78 minutes with an average time of 47 minutes, the volume of blood loss ranged 50-120 mL with an average volume of 85 mL, getting-outof- bed time ranged 2-14 days with an average time of 7.4 days; the weight bearing time ranged 10-14 weeks with an average time of 12.4 weeks. No intra-operative femoral fractures and no regional or deep infection occurred during hospital ization period. Seventeen cases were followed up from 3 months to 12 months with an average time of 9.4 months, and achieved bone heal ing within 15-18 weeks with an average time of 16.5 weeks. No compl ications such as delay heal ing, coxa vara or coxa valga, cut-out and screw extraction occurred. Fifteen cases were followed up over 9 months; according to the Harris criterion for evaluation, the results were excellent in 13 cases, good in 1 case and fair in 1 case, the excellent and good rate was 93.3%. Conclusion PFNAR has the advantages of micro invasion, easy-to-perform, less blood loss, less bone loss and stable fixation in treatment of unstable comminuted intertrochanteric fracture, especially in old patients with osteoporosis.

    Release date:2016-09-01 09:14 Export PDF Favorites Scan
  • Application of three-dimensional printed total scapula for reverse shoulder arthroplasty in treatment of scapular tumors

    ObjectiveTo investigate the effectiveness of three-dimensional (3D) printed total scapula for reverse shoulder arthroplasty in the treatment of scapular tumors. MethodsBetween November 2017 and December 2021, 5 patients with scapular tumors were treated by reverse shoulder arthroplasty with 3D printed total scapula. There was 1 male and 4 females. The age ranged from 44 to 59 years, with an average of 50.4 years. There were 2 cases of chondro sarcoma, 1 case of high-grade osteosarcoma, 1 case of lung cancer with scapular metastasis, and 1 case of ligamentoid fibromatosis recurrence. The disease duration was 4-8 months, with an average of 5.8 months. According to the Musculoskeletal Tumor Society (MSTS) scapular girdle classification criteria, 4 cases of tumors involved both S1 and S2 zones, and 1 case involved S2 zone. The tumor diameters ranged from 4.2 to 11.2 cm, with an average of 6.1 cm. The operation time, intraoperative blood loss, and blood transfusion were recorded. During follow-up, the MSTS score was used to evaluate the recovery of limb function of the patients. The sink depth of the affected shoulder, complications, and oncological outcomes were observed. The position of the prosthesis was reviewed by imaging. ResultsThe operation time ranged from 155 to 230 minutes, with an average of 189 minutes. The intraoperative blood loss was 100-1 500 mL, with a median of 600 mL. Two patients were received blood transfusion of 800 mL and 1 850 mL respectively during operation. All incisions healed by first intention, and no complications such as infection occurred. All patients were followed up 4-22 months, with an average of 13 months. Two patients died at 8 and 15 months after operation respectively due to multiple metastases and organ failure. At last follow-up, the MSTS score of all patients was 73%-83%, with an average of 77.4%. The affected shoulder was 2-4 cm lower than the contralateral side, with an average of 3 cm. Imaging examinations showed that no prosthesis loosening, dislocation, or fracture occurred during follow-up. Conclusion Reverse shoulder arthroplasty with 3D printed total scapula can obtain good shoulder function and appearance. Patients have high acceptance and satisfaction with this surgical method.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content