ObjectiveTo investigate and evaluate the effectiveness of the distal radius microplate locking plate for the treatment of displaced fracture of medial clavicle.MethodsBetween January 2013 and June 2017, 18 cases of obvious displaced fracture of medial clavicle were treated with distal radius microlocking plate. There were 10 males and 8 females, with an average age of 51.4 years (range, 18-88 years). Causes of injury included traffic accident injury in 15 cases, heavy object injury in 3 cases; all of them were closed injury. According to Edinburgh classification, 15 cases were ⅠB1 type and 3 cases were ⅠB2 type. Fracture displacement was 12-21 mm (mean, 16.3 mm). The time from injury to operation was 3-7 days (mean, 4.3 days). After operation, the clinical healing and complications of fracture were observed, and shoulder function was evaluated according to Rockwood’s scoring criteria.ResultsNo incisional infection, neurovascular injury, or other early complications occurred. All 18 patients were followed up 8-15 months (mean, 12 months). All fractures reached clinical osseous union, and the healing time was 8-24 weeks (mean, 16.6 weeks). Postoperative plate loosening occurred in 1 case, which was removed surgically, while other patients did not suffer from complications such as bone nonunion, displacement, internal fixator loosening, and loss of reduction. At last follow-up, according to Rockwood’s scoring criteria, the results were excellent in 12 cases and good in 6 cases.ConclusionThe distal radius microplate locking plate is effective for the treatment of displaced medial clavicle fracture, which has few complications, and is feasible for early functional exercise, and is helpful for the recovery of shoulder joint function.
ObjectiveTo investigate the effect of the screw blade position on the effectiveness of proximal femoral nail anti-rotation (PFNA) internal fixation for unstable intertrochanteric fractures in the elderly.MethodsA clinical data of 131 elderly patients with unstable intertrochanteric fractures who were treated with PFNA internal fixation between January 2010 and January 2017 was retrospectively analyzed. According to the anteroposterior X-ray films, the screw blades were placed in the middle of the femoral neck in 72 patients (group A) and at one-third of the femoral neck in 59 patients (group B). There was no significant difference between the two groups (P>0.05) in the gender, age, bone density, classification of fractures, other medical diseases, and the time between injury and operation. Multiple treatment indexes were analyzed, including complications, hip Harris score, the healing status of fracture, tip-apex distance (TAD), and the height of the tail nail.ResultsAll patients were followed up 11-14 months, with an average of 12.1 months. All incisions healed by first intention with no complications. All fractures healed and no significant difference in bone healing time between the two groups (Z=−0.190, P=0.849). At 6 months after operation, TAD was (2.23±0.07) cm in group A and (2.85±0.12) cm in group B, showing significant difference (t=−47.643, P=0.000); and the height of the tail nail was (1.72±0.14) cm in group A and (0.53±0.26) cm in group B, showing significant difference (t=31.031, P=0.000). According to the Harris score, the hip functions were rated as excellent in 48 cases, good in 15 cases, and poor in 9 cases in group A, while as excellent in 38 cases, good in 16 cases, and poor in 5 cases in group B, with no significant difference between the two groups (Z=−0.075, P=0.941).ConclusionFor the unstable intertrochanteric fracture in the elderly, the PFNA internal fixation with appropriated TAD and the screw blades placed in the middle or at one-third of the femoral neck can obtain good effectiveness.
ObjectiveTo evaluate the effectiveness of percutaneous retrograde pubic screw implantation assisted by hollow pedicle opener in pubic branch fractures.MethodsThe clinical data of 42 patients with pubic branch fractures treated by hollow screw fixation between March 2008 and March 2019 were analyzed retrospectively. According to the operation method, they were divided into the traditional operation group (20 cases in group A, fixed with traditional retrograde pubic screws) and the modified operation group (22 cases in group B, fixed with percutaneous retrograde pubic screws assisted by hollow pedicle opener). There was no significant difference (P>0.05) between the two groups in terms of gender, age, cause of injury, fracture classification, comorbidity, and time from injury to operation. The operation time, blood loss, incision length, screw length, and complications were recorded and compared between the two groups. The fracture reduction was evaluated according to Matta standard on the next day after operation, and the function was evaluated by Majeed score at 12 months after operation.ResultsThe operation was successfully completed in both groups. The operation time, blood loss, and incision length of group B were significantly less than those of group A (P<0.05); there was no significant difference in screw length between the two groups (t=0.793, P=0.437). All patients were followed up 8-24 months, with an average of 16.8 months. There was no complication in the two groups, such as injury of blood vessels and nerves, fracture of internal fixation, screw entering into joint cavity, and nonunion of fracture. There was no significant difference in the fracture healing time between the two groups (t=−1.068, P=0.299). There were 2 cases of incision infection, 1 case of incision fat liquefaction, 2 cases of lower extremity deep vein thrombosis in group A, the incidence of complications was 25.0%; there was only 1 case of lower extremity deep vein thrombosis in group B, the incidence of complication was 4.5%, which was lower than that in group A, but the difference was not significant (χ2=2.104, P=0.147). In group A, 1 case was found to be dislocated, but in group B, there was no dislocated fracture. There was no significant difference between the two groups in the evaluation of Matta imaging on the next day after operation and the evaluation of Majeed function at 12 months after operation (P>0.05).ConclusionPercutaneous retrograde pubic screw implantation assisted by hollow pedicle opener is effect for the pubic branch fractures with the advantage of smaller incision, shorter operation time, and less bleeding compared with traditional methods.
ObjectiveTo estimate the outcome of cerclage followed by a figure-of-eight tension band with a single titanium wire for the treatment of patellar fracture.MethodsA retrospective analysis was made on the clinical data of 46 patients with patellar fractures treated between June 2012 and November 2014. There were 30 males and 16 females, aged 20-86 years (mean, 54 years). The fracture causes included falling in 27 cases, traffic accident in 16 cases, and knock in 3 cases. There were 41 cases of closed fractures and 5 cases of open fracture. The injury located at the left side in 24 cases and the right side in 22 cases. According to AO classification, fracture was rated as type 34-A in 3 cases, as type 34-B in 1 case, as type 34-C1 in 7 cases, as type 34-C2 in 13 cases, and as type 34-C3 in 22 cases. The time between injury and operation ranged 1-12 days (mean, 3.7 days). During operations, a single titanium wire was used to pass around the patellar, followed a figure-of-eight wrapping, to tight and fix at the tension of 35 kg.ResultsAll incisions healed primarily. The patients were followed up 20.6 months on average (range, 6-24 months). Partial wire loosening was found in 2 cases, irritation of skin or soft tissue in 1 case. The X-ray examination showed bony healing at 3 months after operation, without breakage of titanium wire. The internal fixation was removed in 38 cases at 12 months after operation. According to the Böstman rating score, the mean score was 28.34 (range, 24-30) at 12 months after ope-ration; the results were excellent in 42 cases and good in 4 cases, with an excellent and good rate of 100%.ConclusionFor patellar fracture, cerclage followed by a figure-of-eight tension band with a single titanium wire is able to achieve an effective stability and to allow early motion for patient with less complication.