west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "LIU Taotao" 3 results
  • Study on the intervention of platelet biological activity by ultrasound

    Platelets are non-nucleated blood effector cells, which plays an important role in coagulation, hemostasis, and thrombosis. However, platelets are extremely susceptible to activation by external stimuli, which in turn damages the platelet’s natural biological activity and affects its biological function. Platelet biological activity has become a hotspot in the field of vascular diseases. In this study, ultrasound parameters (ultrasound intensity and duration time) were used to intervene in the biological activity of platelets. The response of platelets to ultrasound energy was explored from the aspects of platelet morphology, aggregation ability and particle release (the expression of P-selectin and the number of particles). The results showed that the ultrasound intensity of 0.25 W/cm2 (1 MHz, 60 s) had no effect on the morphology, aggregation ability and particle release of platelets. When the ultrasonic intensity was increased to greater than 0.25 W/cm2, the generation of platelet pseudopods, morphological changes, increase of particle release, as well as effect on aggregation were observed. When the ultrasound duration time was 60 s (1 MHz, 0.25 W/cm2), it had no effect on the biological activity of platelets. However, when the ultrasound time was greater than 60 s, the morphology, aggregation ability and microparticles release would been induced with no effect on the secretion of CD62P and total protein components. Therefore, when the ultrasound parameters were 1 MHz and 0.25 W/cm2 with 60 s duration time, the ultrasound energy had no effect on the biological activity of platelets. The results in this study are of great significant for ultrasound energy intervention for the treatment of platelet-related diseases.

    Release date: Export PDF Favorites Scan
  • Advanced methods of data extraction for continuous outcomes in meta-analysis

    Sample size, mean and standard deviation are necessary when conducting meta-analysis for continuous outcomes. Advanced methods of data extraction were needed if the mean and the standard deviation couldn’t be obtained from a literature directly. Eight methods were introduced and two examples were given to illustrate how to apply the methods.

    Release date:2017-01-18 07:50 Export PDF Favorites Scan
  • Methods of data extraction in meta-analysis of diagnostic accuracy study

    Receiving the amount of true positives, false positives, false negatives and true negatives is necessary when conducting meta-analysis of diagnostic tests. Advanced methods of data extraction are required if these data could not be directly obtained from a literature. We introduced three methods and discussed the theories. An example was then given to illustrate how to apply the methods.

    Release date:2018-09-12 03:22 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content