west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "LIU Yijun" 5 results
  • Prospective study of three-dimensional-printed in vitro guide plates assisted hip arthroscopy in treatment of Cam-type femoroacetabular impingement

    Objective A prospective study was conducted to investigate the feasibility and effectiveness of three-dimensional (3D)-printed in vitro guide plates assisted hip arthroscopy in the treatment of Cam-type femoroacetabular impingement (FAI). Methods The clinical data of 25 patients with Cam type FAI who met the selection criteria between December 2016 and September 2022 were collected. There were 13 males and 12 females with an average age of 42 years (range, 19-66 years). The disease duration ranged from 3 to 120 months, with an average of 22.2 months. The preoperative range of internal rotation-external rotation was (28.7±4.50)°, α angle was (69.04±0.99)°, visual analogue scale (VAS) score was 6.5±0.2, and modified Harris hip score (HHS) was 50.5±0.7. All patients were treated with hip arthroscopy assisted by 3D printed in vitro guide plate. The incidence of complications was observed postoperatively, the acetabular coverage and the α angle of the affected hip joint were measured by hip CT before and after operation, and the glenoid labrum injury was observed by MRI. The percentage of overlap between the Cam plasty area and the preoperative simulated grinding area was calculated by three-dimensional CT+reconstruction, and the difference between them was evaluated. The effectiveness was evaluated by VAS score and modified HHS score. ResultsPostoperative dorsalis pedis numbness occurred in 1 case, and the symptoms disappeared after 1 month of conventional drug treatment such as neurotrophy. Two cases of perineal skin injury occurred, and healed after symptomatic treatment. There was no male erectile dysfunction, deep incision infection, pulmonary embolism, or other serious complications occurred. The percentage of overlap between the Cam plasty area and the preoperative simulated grinding area was 81.6%-95.3%, with an average of 89.8%. All 25 patients were followed up 6-12 months, with an average of 8 months. At last follow-up, the range of internal rotation-external rotation was (40.10±2.98)°, the α angle was (43.72±0.84)°, the VAS score was 1.8±0.2, and the modified HHS score was 72.1±1.3, which significantly improved when compared with those before operation (P<0.05). ConclusionThe treatment of Cam-type FAI with 3D printed in vitro guide plates assisted hip arthroscopy is safe and feasible, and can achieve good effectiveness.

    Release date: Export PDF Favorites Scan
  • A study on the level of gastrin in patients with type 2 diabetes mellitus and gastroesophageal reflux disease

    Objective To investigate the gastrin level in patients with type 2 diabetes mellitus (T2DM) with gastroesophageal reflux disease (GERD), and analyze the possible mechanism of gastrin in the pathogenesis of T2DM combined with GERD. Methods Thirty-eight patients with T2DM combined with GERD treated between January 2013 and January 2015 were designated as group A; 40 patients with T2DM only were regarded as group B; 36 patients with GERD only were regarded as group C; and another 40 healthy volunteers who underwent physical examination at the same period were regarded as group D. The fasting serum levels of gastrin were measured and compared among the above four groups. Results The fasting serum level of gastrin was significantly higher in group A [(116.53±22.02) pg/mL] than group B [(101.89±20.76) pg/mL], group C [(90.04±21.16) pg/mL], and group D [(92.48±19.69) pg/mL] (P<0.01). The fasting serum level of gastrin in group B was significantly higher than group C and D (P<0.05). There was no significant difference between group C and D in terms of fasting serum level of gastrin (P>0.05). Conclusions There is a high level of gastrin in patients with GERD combined with T2DM. Abnormal secretion of gastrin may be closely related with the occurrence and development of T2DM and GERD.

    Release date:2017-03-27 11:42 Export PDF Favorites Scan
  • Effectiveness analysis of computer-aided technology in the treatment of primary elbow osteoarthritis combined with stiffness under arthroscopy

    Objective To explore the effectiveness of computer-aided technology in the treatment of primary elbow osteoarthritis combined with stiffness under arthroscopy. Methods The clinical data of 32 patients with primary elbow osteoarthritis combined with stiffness between June 2018 and December 2020 were retrospectively analyzed. There were 22 males and 10 females with an average age of 53.4 years (range, 31-71 years). X-ray film and three-dimensional CT examinations showed osteophytes of varying degrees in the elbow joint. Loose bodies existed in 16 cases, and there were 7 cases combined with ulnar nerve entrapment syndrome. The median symptom duration was 2.5 years (range, 3 months to 22.5 years). The location of bone impingement from 0° extension to 140° flexion of the elbow joint was simulated by computer-aided technology before operation and a three-dimensional printed model was used to visualize the amount and scope of impinging osteophytes removal from the anterior and posterior elbow joint to accurately guide the operation. Meanwhile, the effect of elbow joint release and impinging osteophytes removal was examined visually under arthroscopy. The visual analogue scale (VAS) score, Mayo elbow performance score (MEPS), and elbow range of motion (extension, flexion, extension and flexion) were compared between before and after operation to evaluate elbow function. Results The mean operation time was 108 minutes (range, 50-160 minutes). All 32 patients were followed up 9-18 months with an average of 12.5 months. There was no other complication such as infection, nervous system injury, joint cavity effusion, and heterotopic ossification, except 2 cases with postoperative joint contracture at 3 weeks after operation due to the failure to persist in regular functional exercises. Loose bodies of elbow and impinging osteophytes were removed completely for all patients, and functional recovery was satisfactory. At last follow-up, VAS score, MEPS score, extension, flexion, flexion and extension range of motion significantly improved when compared with preoperative ones (P<0.05). Conclusion Arthroscopic treatment of primary elbow osteoarthritis combined with stiffness using computer-aided technology can significantly reduce pain, achieve satisfactory functional recovery and reliable effectiveness.

    Release date: Export PDF Favorites Scan
  • Effectiveness of arthroscopic long head of biceps tendon transposition combined with Swivelock anchor double fixation for massive and irreparable rotator cuff tears

    Objective To investigate the effectiveness of arthroscopic long head of biceps tendon (LHBT) transposition combined with Swivelock anchor double fixation in treatment of massive and irreparable rotator cuff tears. Methods Between June 2019 and November 2021, 25 patients with massive and irreparable rotator cuff tears were treated by arthroscopic LHBT transposition combined with Swivelock anchor double fixation. There were 12 males and 13 females. The age ranged from 47 to 74 years (mean, 62.4 years). The disease duration ranged from 1 to 62 months (median, 7 months). The rotator cuff tears were classified as Hamada grade 2 in 25 cases and Goutallier grade 1 in 2 cases, grade 2 in 22 cases, and grade 3 in 1 case. Pre- and post-operative shoulder range of motion (ROM), visual analogue scale (VAS) score, University of California Los Angeles (UCLA) score, and Constant-Murley score were recorded. Postoperative complications were observed. The reconstructed tissue integrity was confirmed by MRI. Results All operations were successfully completed. The operation time was 120-330 minutes (mean, 189.6 minutes). All incisions healed by first intention. All patients were followed up 10-36 months (mean, 22.0 months). At last follow-up, the ROM in forward flexion, abduction, and external rotation, VAS score, UCLA score, and Constant-Murley score were superior to those before operation, and the differences were significant (P<0.05). According to UCLA scoring standard, shoulder joint function was rated as excellent in 5 cases, good in 18 cases, and poor in 2 cases, with an excellent and good rate of 92.0%. No other complications occurred except shoulder joint adhesion in 2 cases. At last follow-up, MRI examination showed no retear of rotator cuff, and LHBT was intact. Conclusion For massive and irreparable rotator cuff tears, arthroscopic LHBT transposition combined with Swivelock anchor double fixation can increase the force of pressing the humeral head, effectively relieve the pain, improve the ROM of joints, maximize the recovery of shoulder function, and do not increase the number of anchor nails.

    Release date: Export PDF Favorites Scan
  • The evaluation and handling of overlapping in umbrella reviews

    The overlap of literature in umbrella reviews can affect the reliability and accuracy of research conclusions, leading to results with a higher risk of bias. Therefore, it becomes crucial to assess the degree of overlapping and how to handle it. In order to avoid redundant calculations and reduce the risk of bias, researchers need to quantify the degree of literature overlap and adopt corresponding processing strategies. This paper provides a detailed introduction to the calculation methods of overlapping and different strategies for handling overlapping, aiming to provide a reference and guidance for domestic scholars' understanding and application of this method.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content