  • Evaluation of the Application of UF-1000i Automatic Urine Dreg Analyzer in Excluding Urinary Tract Infection

    目的 评价UF-1000i全自动尿沉渣分析仪中沉渣定量模块中白细胞和细菌参数阈值在排除尿路感染的应用价值。 方法 选取2 580份清洁中段尿液, 同时进行细菌培养菌落计数和UF-1000i尿沉渣白细胞和细菌定量分析,建立ROC曲线确定白细胞参数与细菌参数阈值。 结果 以尿定量培养菌落计数G?菌≥105 cfu/mL,G+菌≥104 cfu/mL为阳性参考标准,当白细胞沉渣定量为100/μL时,UF-1000i尿沉渣分析仪检测灵敏度为64%,特异度为75%,阴性预测值为96%;当UF-1000i细菌计量为901/μL时,检测灵敏度为68.3%,特异度为92.8%,阴性预测值为97%。 结论 UF-1000i检测新鲜尿标本白细胞的测定值lt;100/μL,细菌值lt;901/μL时能够作为临床早期排除尿路感染的依据之一。

    Release date:2016-09-07 02:37 Export PDF Favorites Scan
  • Clinical evaluation of three chemiluminescence immunoassays for human immunodeficiency virus antigen and antibody screening

    Objective To evaluate the performance of i3000 direct chemiluminescence detection of human immunodeficiency virus (HIV) antigen and antibody (Ag/Ab) screening assay (Maccura), compared with E170 electrochemiluminescence method (Roche, Elecsys® HIV Combi PT assay) and IS1200 indirect chemiluminescence method (Maccura). Methods Ten HIV seroconversion panels and 11 p24 antigen positive samples from West China Hospital of Sichuan University from April to December 2017 were used to evaluate the sensitivity of those three assays. A total of 351 samples were collected for consistency evaluation, including 350 HIV Ag/Ab test samples (200 HIV-1 positive plasma samples and 150 HIV 1+2 negative plasma samples) from West China Hospital of Sichuan University from April to December 2017, and one commercial HIV-2 sera. A total of 98 interfere samples for HIV testing were collected from West China Hospital of Sichuan University from April to December 2017. Results In the sensitivity evaluation, there were 63 samples from the 10 seroconversion panels, in which Roche E170 detected 25 samples, Maccura i3000 detected 23 samples, and Maccura IS1200 detected 22 samples; Maccura i3000 and Roche E170 assays detected all the p24 antigen positive samples (11, 100%), while Maccura IS1200 only detected 10 samples. In the consistency evaluation, Maccura i3000 had nice consistency with both Roche E170 and Maccura IS1200 (kappa>0.9, P<0.001). In the interference evaluation, there were two false positives in Maccura i3000 detection, one case of rheumatoid arthritis and one case of syphilis. Conclusion In addition to high throughput and good consistency, Maccura i3000 direct chemiluminescence reagent has high sensitivity and a short window period, which can meet clinical needs.

    Release date: Export PDF Favorites Scan
  • Clinical application of combining human immunodeficiency virus antigen/antibody assay screening and Western blot or human immunodeficiency virus nucleic acid

    ObjectiveTo evaluate the clinical significance of human immunodeficiency virus (HIV) testing algorithm combining antigen/antibody assay screening with Western Blot (WB) or HIV nucleic acid.MethodsData of HIV antigen and antibody screening samples in West China Hospital of Sichuan University in 2018 were retrospectively analyzed. The 4th generation antigen and antibody reagents were used for initial screening, and the 3rd generation antibody reagents were used for reexamination. WB or HIV nucleic acid detection was performed as supplementary test.ResultsA total of 217 803 samples were initially screened, 718 samples were positive in initial screening (0.33%) and 513 samples were confirmed positive (0.24%). The 718 initial positive samples were confirmed by WB, among them, 513 (71.45%) were positive, 163 (22.70%) were negative, and 42 (5.85%) were indeterminate. Fifteen samples which were negative or indeterminate were detected by HIV RNA, as a result, 6 were positive. Two of four patients turned into positive during follow-up. Among the 536 samples which were positive in both the 4th and 3rd generation assay, there were 513 (95.71%) positive, 6 (1.12%) negative, and 17 (3.17%) indeterminate confirmed by WB; among the 182 samples which were positive in the 4th generation assay but negative in the 3rd generation assay, there were none (0.00%) positive, 157 (86.26%) negative, and 25 (13.74%) indeterminate confirmed by WB. The positive rate of confirmation test of samples positive in the 4th and 3rd generation assay (95.71%, 513/536) was significantly higher than that of samples positive in the 4th generation assay but negative in the 3rd generation assay (0%, 0/182), and the difference was statistically significant (χ2=610.091, P<0.001). WB band types for positive samples were dominated by the whole bands and sub-bands, accounting for 82.26%. The cut off index in ≥5 bands group was higher than that in < 4 bands group (P<0.001).ConclusionsSamples with both the 4th and 3rd generation assay positive have a high positive rate of confirmation test, and a supplementary test is needed to be done as soon as possible to confirm the diagnosis. Samples with only the 4th generation assay positive have a low positive rate of confirmation test. But for patients with a high-risk history, HIV nucleic acid should be done as soon as possible for early diagnosis.

    Release date:2020-08-25 10:08 Export PDF Favorites Scan
  • The correlation between post-traumatic stress disorder and perceived stress in suspected COVID-19 patients quarantined in hospital

    ObjectiveTo understand the relationship between post-traumatic stress disorder (PSTD) and perceived stress in suspected coronavirus disease 2019 (COVID-19) patients quarantined in hospital.MethodsA cross-sectional study of 93 suspected COVID-19 patients in one of grade-A tertiary hospital in Southwest China was carried out to evaluate the incidence of perceived stress and post-traumatic stress symptoms among these patients using the standardized Perceived Stress Scale-10 (PSS-10) and PTSD Checklist-5 (PCL-5), respectively. Pearson correlation was used to analyze the correlation between PCL-5 and PSS-10 scores.ResultsTotal PSS-10 and PCL-5 scores were 16.7±5.2 and 17.0±11.6 in 93 suspected COVID-19 patients, respectively. Positive correlations between PSS-10 and PCL-5 scores were detected (Pearson’s r=0.722, P=0.000).ConclusionsThe occurrence and development of PSTD of suspected COVID-19 patients have the relationship with the early perceived pressure. It suggests that medical staff should identify and intervene the perceived pressure level of patients who are under quarantine as suspected COVID-19 early and effectively, so as to reduce the occurrence of PTSD.

    Release date:2020-09-27 06:38 Export PDF Favorites Scan
  • The construction and evaluation of heart preservation model for jumping donor heart based on extracorporeal membrane oxygenation technology

    ObjectiveTo explore the construction of heart preservation model of empty beating donor based on extracorporeal membrane oxygenation (ECMO). MethodsFrom January 2022 to August 2023, 20 Guangxi Bama miniature pigs weighing 25-30 kg were selected, half male and half female. Under general anesthesia and heparinization, a midline thoracotomy was performed. The pericardium was cut after freeing the anterior and posterior vena cavae, and a perfusion needle was inserted near the brachiocephalic artery in the ascending aorta, connected to a blood collection bag to collect 500-600 mL of blood. The anterior and posterior vena cavae were ligated, the aorta was blocked and perfused with HTK solution to stop the heart beating. The superior and inferior vena cavae were cut off, the right pulmonary vein was decompressed, the aorta and left and right pulmonary arteries and veins were cut off, and the whole heart was removed. An ECMO device was used to continuously perfuse a cardioprotective solution mainly composed of oxygenated warm blood, maintaining the isolated pig heart beating for 8 hours, monitoring (once/hour) ECMO perfusion parameters, blood gas indicators, perfusate electrolytes, detecting inflammatory factors, myocardial enzymes, myoglobin, and troponin levels. Myocardial tissue was taken for hematoxylin-eosin (HE) staining to observe myocardial cell damage and evaluate the quality of heart preservation. ResultsAmong the 20 isolated beating preservation pig hearts, 17 successfully resumed beating, 3 experienced ventricular fibrillation, resuscitated after intracardiac electrical defibrillation, and all 20 pig hearts successfully beat for 8 hours. There was no statistical difference in ECMO perfusion parameters, blood gas indicators, perfusate electrolytes, and inflammatory factors at each time point (P>0.05). There were statistical increases in myocardial enzymes, myoglobin, and troponin levels (P<0.05). HE staining results suggested that there was no severe myocardial damage. ConclusionECMO technology can be used for pig heart preservation with good results, and this study provides experimental evidence for improving heart preservation research in clinical heart transplantation.

    Release date: Export PDF Favorites Scan