find Author "LUO Xiaozhong" 4 results
  • EXPERIMENTAL STUDY OF TISSUE ENGINEERED BONE WITH CRYOPRESERVATON ON HEALING OF BONE DEFECTS

    Objective To investigate the effect of tissue engineered bone with cryopreservation on healing of bone defects and to explore feasibility of cryopreservation for tissue engineered bone. Methods Tissue engineeredbones were constructed with osteoblasts being seeded onto bio-derived materials made from freshhuman bones,and they were preserved at 4℃ and -196℃ for 3 months and 6 monthsrespectively.They were applied to repair segmental bone defects of rabbit’s radius while the tissue engineered bone without cryopreservation and bio-derived materials were brought into control groups.The experiment was divided into groups A3,A6,B3,B6,C and D(group A3:tissue engineered bones were preserved at 4℃ for 3 months; group A6:tissue engineered bones were preserved at 4℃ for 6 months;group B3:tissue engineered bones were preserved at -196℃ for 3 months; group B6:tissue engineered bones were preserved at -196℃ for 6 months; group C: tissueengineered bones without cryopreservation; group D: bio-derived materials). Macroscopical and histologial examination were done at the 2nd,4th,6th,12th weeks, X-ray examination was done at the 6th,12th weeks and biomechanics were determined at 12th weeks after operation respectively. Results Macroscopical observation showed no significant differences among group A3, A6, B3, B6 and C, but less new bone formation and more obvious boundary in group D were observed. Histological observation showed more collagen and new bone around the edge of implant of group A3, A6, B3, B6 and C than group D, and histological evaluation showed significant differences between group D and other groups(P<0.05). Radiographic observation showed no absorbability of the implant cortex and less new bone formation in group D, but the unity between implant and host bone, medullary cavity reopened, disappearance of fracture line and fine bone modelling were observed in other groups at 12 weeks after operation. Biomechanics between group D and other groups showed significant differences(P<0.05). Conclusion Cryopreservation (4℃ and -196℃) were capable of preserving tissue engineered bone for long time, and tissue engineered bone withcryopreservation has significant effect on healing of bone defects. The methods f it clinical application.

    Release date:2016-09-01 09:29 Export PDF Favorites Scan
  • Application of three-dimensional printing technology in treatment of internal or external ankle distal avulsed fracture

    ObjectiveTo explore the effectiveness and advantage of three-dimensional (3D) printing technology in treatment of internal or external ankle distal avulsed fracture.MethodsBetween January 2015 and January 2017, 20 patients with distal avulsed fracture of internal or external ankle were treated with the 3D guidance of shape-blocking steel plate fixation (group A), and 18 patients were treated with traditional plaster external fixation (group B). There was no significant difference in gender, age, injury cause, disease duration, fracture side, and fracture type between 2 groups (P>0.05). Recording the fracture healing rate, fracture healing time, the time of starting to ankle functional exercise, residual ankle pain, and evaluating ankle function recovery of both groups by the American Orthopaedic Foot and Ankle Society (AOFAS) score.ResultsAll patients were followed up 8-24 months, with an average of 15.5 months. In group A: all incisions healed by first intention, the time of starting to ankle functional exercise was (14±3) days, fracture healing rate was 100%, and the fracture healing time was (10.15±2.00) weeks. At 6 months, the AOFAS score was 90.35±4.65. Among them, 13 patients were excellent and 7 patients were good. All patients had no post-operative incision infection, residual ankle pain, or dysfunction during the follow-up. In group B: the time of starting to ankle functional exercise was (40±10) days, the fracture healing rate was 94.44%, and the fracture healing time was (13.83±7.49) weeks. At 6 months, the AOFAS score was 79.28±34.28. Among them, 15 patients were good, 2 patients were medium, and 1 patient was poor. During the follow-up, 3 patients (16.67%) had pain of ankle joint with different degrees. There were significant differences in the postoperative fracture healing rate, fracture healing time, the time of starting to ankle functional exercise, and postoperative AOFAS score between 2 groups (P<0.05).ConclusionApplication of 3D printing technology in treatment of internal or external ankle distal avulsed fracture is simple, safe, reliable, and effective. In particular, it is an ideal treatment for avulsed fracture.

    Release date:2018-02-07 03:21 Export PDF Favorites Scan
  • COMPARISON STUDY ON LOCKING COMPRESS PLATE EXTERNAL FIXATOR AND STANDARD EXTERNAL FIXATOR FOR TREATMENT OF TIBIAL OPEN FRACTURES

    Objective To compare the clinical results of locking compress plate (LCP) as an external fixator and standard external fixator for treatment of tibial open fractures. Methods Between May 2009 and June 2012, 59 patients with tibial open fractures were treated with LCP as an external fixator in 36 patients (group A), and with standard external fixator in 23 patients (group B). There was no significant difference in gender, age, cause of injury, affected side, type of fracture, location, and interval between injury and surgery between 2 groups (P gt; 0.05). The time of fracture healing and incision healing, the time of partial weight-bearing, the range of motion (ROM) of knee and ankle, and complications were compared between 2 groups. Results The incidence of pin-track infection in group A (0) was significantly lower than that in group B (21.7%) (P=0.007). No significant difference was found in the incidence of superficial infection and deep infection of incision, and the time of incision healing between 2 groups (P gt; 0.05). Deep vein thrombosis occurred in 5 cases of group A and 2 cases of group B, showing no significant difference (χ2=0.036, P=0.085). All patients were followed up 15.2 months on average (range, 9-28 months) in group A, and 18.6 months on average (range, 9-47 months) in group B. The malunion rate and nonunion rate showed no significant difference between groups A and B (0 vs. 13.0% and 0 vs. 8.7%, P gt; 0.05); the delayed union rate of group A (2.8%) was significantly lower than that of group B (21.7%) (χ2=5.573, P=0.018). Group A had shorter time of fracture healing, quicker partial weight-bearing, greater ROM of the knee and ankle than group B (P lt; 0.05). Conclusion The LCP external fixator can obtain reliable fixation in treating tibial open fracture, and has good patients’ compliance, so it is helpful to do functional exercise, improve fracture healing and function recovery, and reduce the complication incidence.

    Release date:2016-08-31 04:05 Export PDF Favorites Scan
  • Study on development and biomechanics test of plastic rod-hook plate

    ObjectiveTo develop a new type of internal fixation device which can be used to treat the minor avulsion fracture of the medial malleolus, lateral malleolus, the base of the fifth metatarsal, and the ulnar styloid process, and investigate the reliability and effectiveness of the device through biomechanical test.MethodsEighty human’s bone specimens with complete medial malleolus, lateral malleolus, the base of the fifth metatarsal, and the ulnar styloid process were selected and measured the anatomic indexes (the height, width, and thickness of medial malleolus, lateral malleolus, the base of the fifth metatarsal, and the ulnar styloid process). The CT three-dimensional reconstruction data of 200 healthy adults which including medial malleolus, lateral malleolus, the base of the fifth metatarsal, and the ulnar styloid process was also selected and measured the anatomic indexes by Mimics software. The plastic rod-hook plate was designed according to the measured results and prepared. Forty fresh porcine lower limb specimens were randomly divided into groups A and B (20 in each group), and 8 adult lower limb specimens including 4 left and 4 right were also randomly divided into groups A and B (4 in each group). All specimens were prepared for avulsion fracture of medial malleolus. Then, the fractures were fixed with plastic rod-hook plate in group A and wire anchor in group B. The load and axial torsion test of ankle joint were carried out by universal biomechanical testing machine.ResultsAccording to the anatomical characteristics, a plastic rod-hook plate was designed successfully. The biomechanical test results between animal and human specimens were consistent. There was a linear relationship between load and displacement in the ankle distal load test. The displacement when loaded to the maximum load was significantly lower in group A than in group B (P<0.05). The torsion angle and torque were significantly higher in group A than in group B when the internal fixation failed in the axial torsion test of the ankle joint (P<0.05), and the torsion angle was significantly smaller in group A than in group B when the torque was 1 N·m (P<0.05), and the maximum torque was also significantly higher in group A than in group B (P<0.05). However, there was no significant difference in torsion angle between the two groups in the maximum torque (P>0.05).ConclusionThe biomechanical properties of plastic rod-hook plate is obviously better than wire anchor, and the fixation of avulsion fracture with plastic rod-hook plate is easy to operate, which is expected to be used in the clinical treatment of minor avulsion fractures such as medial malleolus, lateral malleolus, base of the fifth metatarsal, and ulna styloid process.

    Release date:2019-11-21 03:35 Export PDF Favorites Scan