west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "LUOHongyan" 2 results
  • Design of Low-intermediate Frequency Electrotherapy and Pain Assessment System

    Aiming at the single treatment and the design separation between treatment and assessment in electrotherapy equipment, a kind of system including low-intermediate frequency treatment and efficacy evaluation was developed. With C8051F020 single-chip microcomputer as the core and the circuit design and software programming used, the system realized the random switch of therapeutic parameters, the collection, display and data storage of pressure pain threshold in the assessment. Experiment results showed that the stimulus waveform, current intensity, frequency, duty ratio of the system output were adjustable, accurate and reliable. The obtained pressure pain threshold had a higher accuracy (<0.3 N) and better stability, guiding the parameter choice in the precise electrical stimulation. It, therefore, provides a reliable technical support for the treatment and curative effect assessment.

    Release date: Export PDF Favorites Scan
  • Design of a Low-power-consuming Magnetoelastic Sensor Detecting System Based on STM32

    Magnetoelastic (ME) sensors, characterized by wireless, passive, low cost and high sensitivity, have widespread applications in various fields. However, its defects of large volume, high power consumption, poor portability and inconveniency for use limit the application prospects of the ME sensors. To solve this problem, the present paper shows a portable, low-power, resonance-type ME sensor detecting system based on STM32. The experimental results indicated that this detecting system allowed the ME sensor to complete the measurement of resonant frequency in different medium and different concentration, with a frequency resolution of less than 1 Hz, and the resonant frequency ratio of ME sensors in different sizes 0.933 8, closing the theoretical value of 0.942 3. Moreover, compared with the traditional impedance analyzer combined detecting system and the existing integrated detecting system, the present system has a power consumption of 0.68 W in operation and of only 2.20 mW in the dormancy mode. Therefore, the system can not only replace the original impedance analyzer combined detecting system, but also significantly improve the power control of the existing integrated detecting system, exhibiting the advantages of higher integration, portable measurement, and fine suitability for long-term monitoring.

    Release date:2016-10-24 01:24 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content