west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "OUYANG Kan" 7 results
  • ARTHROSCOPIC REPAIR OF ROTATOR CUFF TEAR WITH FIVE DIFFERENT METHODS

    Objective To discuss and evaluate the diagnose and surgical techniques of rotator cuff tear with arthroscopic repair and its cl inical results. Methods From November 2006 to April 2008, 22 patients with rotator cuff tear were treated by arthroscopic repair using 5 different methods. There were 13 males and 9 females, aged 28-51 years old (mean37.9 years old). The locations were left shoulder in 6 cases and right shoulder in 16 cases. Eleven cases underwent shoulder joint injury and other 11 cases had no inducement. According to Bigl iani acromion classificatioin, there were 12 cases of type II and 10 cases of type III. There were 5 bursa-side tear, 3 articular-side tear, and 14 full thickness tear. The disease course was 5 months to 6 years (mean 16.6 months). After all the patients underwent acromioplasty, 4 cases were treated by debridement of rotator cuff, 7 cases by single roll suture anchor, 4 cases by double suture anchors, 3 cases by trible suture anchors, and 4 cases by transosseous technique suture. Results Incision healed by first intention and no compl ications occurred in all patients. Twenty-two cases were followed up 12-26 months (mean 15.6 months). The active forward flexion and abduction at the last follow-up were over 150° in 21 cases, 90-l20° in 1 case. Postoperatively, the forward flexion strength was grade 5 in 20 cases and grade 4 in 2 cases. The score of University of Cal ifornia Los Angeles, the pain score, the function score, the forward flexion score, the forward flexion strength were improved significantly when compared with preoperation (P lt; 0.05). The results were excellent in 13 cases and good in 9 cases, the excellent and good rate was 100%. Conclusion Depending on the correct diagnoses, 5 different methods of rotator cuff repair are used according to the different changes of shoulders, the outcome is good in all cases.

    Release date:2016-09-01 09:08 Export PDF Favorites Scan
  • Medium-term clinical outcome of encircled suture for repair of medial meniscus bucket-handle tear

    Objective To investigate the medium-term clinical outcome of encircled suture for repair of medial meniscus bucket-handle tear (BHT). Methods Between March 2011 and June 2013, 78 patients (78 knees) with medial meniscus BHT were treated with encircled suture under arthroscopy. There were 57 males and 21 females with a mean age of 28.3 years (range, 16-39 years). The causes included sports injury in 61 cases, traffic accident injury in 12 cases, and other trauma in 5 cases. Of 78 cases, 35 were acute injury and 43 were chronic injury; 65 cases had combined injury of anterior cruciate ligament rupture. International Knee Documentation Committee (IKDC) score, Lysholm score, and Tegner score were 48.2±6.3, 43.6±4.7, and 2.5±0.6, respectively. Barrett’s assessment standard, MRI, and arthroscopy examination were used for assessment of meniscus healing. IKDC score, Lysholm score, and Tegner score were used for assessment of knee function. Results Primary healing of incisions were achieved in all patients, and no complications occurred. All patients were followed up 26-63 months (mean, 42.8 months). BHT recurrence was observed in 2 patients within 1 year. Clinical healing of meniscus tear was obtained in 72 cases (92.3%) according to Barrett’s assessment standard. The IKDC score, Lysholm score, and Tegner score were significantly improved to 81.5±5.1, 86.9±3.9, and 6.2±0.5 respectively (t=–14.598,P=0.000;t=–18.478,P=0.000;t=–3.362,P=0.002). MRI results showed complete healing in 56 cases, incomplete healing in 15 cases, and unhealing in 7 cases at last follow-up, with a total healing rate of 91.0% (71/78) and a complete healing rate of 71.8% (56/78). In 21 cases undergoing arthroscopy at 18-49 months after operation, complete healing and incomplete healing were observed in 17 cases and 4 cases respectively, with a total healing rate of 100% (21/21) and a complete healing rate of 81.0% (17/21). No re-tear occurred. Conclusion Encircled suture for repair of medial meniscus BHT owns the advantage of firm suturing and good blood supply which can obtain satisfactory medium-term clinical results.

    Release date:2017-04-01 08:56 Export PDF Favorites Scan
  • EXPERIMENTAL STUDY ON FIXED ANGLE ADJUSTMENT IN SIMULTANEOUS RECONSTRUCTION OF ANTEPIOR AND POSTERIOR CRUCIATE LIGAMENTS

    Objective To explore the best flexion angle of the transplantation tendon for fixing joint in simultaneously reconstructing of the anterior cruciate l igament (ACL) and posterior cruciate l igament (PCL) using semitendinosus tendon as autologous graft. Methods Twenty-four clean level New Zealand White rabbits [(aged 6-8 months, male or female, and weighing (2.5 ± 0.2) kg] were selected and divided randomly into 3 groups (n=8) according to fixation angle of the reconstructed l igaments. The bilateral semitendinosus tendons of hind legs were used to reconstruct the PCL and ACL of right hind leg, and the reconstructed l igaments were fixed at knee flexion angles of 90° (group A), 60° (group B), and 30° (group A). The rabbit general situation was observed after operation, and the specimens of the knee joints (including 10 cmdistal end and 10 cm proximal end) were harvested for testing extension and flexion, displacement, and internal and external rotation at 3 months after operation. Results All the rabbits survived to the end of experiment. There was no significant difference in maximal displacements of ACL and PCL among 3 groups (P gt; 0.05). The anterior and posterior displacements of shift in 3 groups were less than 1 mm, suggesting good stabil ity. The anterior displacement and the posterior displacement at 30° flexion and 90° flexion in group A were significantly larger than those in group C (P lt; 0.05). There were significant differences in internal rotation angle and external rotation angle between group A and group C (P lt; 0.05), and there was no significant difference among other groups (P gt; 0.05). Conclusion When simultaneously reconstructing ACL and PCL, the knee flexion angle of 60° for fixing the reconstructed l igaments can achieve the best effect.

    Release date:2016-08-31 05:44 Export PDF Favorites Scan
  • Mid-term effectiveness of LU-tarjet procedure for recurrent anterior shoulder dislocation

    Objective To evaluate the mid-term effectiveness of limited unique coracoid osteotomy suture button fixation Latarjet (LU-tarjet) procedure in treatment of recurrent anterior shoulder dislocation. Methods Between March 2017 and February 2019, 56 patients with recurrent shoulder dislocation were treated with arthroscopic LU-tarjet procedure. There were 44 males and 12 females with an average age of 26.3 years (range, 18-41 years). Shoulder joint dislocation occurred 2-16 times, with an average of 7.5 times. The time from the initial dislocation to operation ranged from 6 months to 13 years, with a median of 4.6 years. Preoperative shoulder joint fear test and re-reduction test were positive in all patients. The Beighton score of joint relaxation ranged from 1 to 7, with an average of 4.1. The shoulder Instability Severity Index Score (ISIS) ranged from 5 to 10, with an average of 7.8. The size of glenoid defects on the affected side ranged from 15% to 32% (mean, 22.4%). All patients had Hill-Sachs injuries of varying degrees. Six patients had re-dislocation after Bankart surgery. The operation time, incision healing, and postoperative complications were recorded. The range of motion (shoulder flexion, extension, abduction, external rotation, 90° external rotation, and internal rotation) and muscle strength in shoulder flexion, abduction, external rotation, and internal rotation) of shoulder joint were compared between pre- and post-operation. The improvement of shoulder function was evaluated using the American Association for Shoulder and Elbow Surgery (ASES) score, Walch-Duplay score, and Rowe score. X-ray films and three-dimensional CT were used to analyze the location, healing, and remolding of bone graft, the repair of glenoid defect, and degenerative changes of the shoulder joint. Results All operations were successfully completed. The operation time ranged from 42 to 98 minutes, with an average of 63 minutes. All incisions healed by first intention. All patients were followed up 5-7 years (mean, 6.3 years). During follow-up, 2 patients experienced shoulder subluxation within 1 year after operation and 1 patient experienced recurrent shoulder joint pain. The remaining patients had no related complications. At last follow-up, there was no significant difference between the two groups (P>0.05) in range of motion (shoulder flexion, extension, abduction, external rotation, 90° external rotation, and internal rotation) and muscle strength in shoulder flexion, abduction, external rotation, and internal rotation). The ASES score, Rowe score, and Walch-Duplay score of shoulder significantly improved when compared with those before operation (P<0.05). Postoperative CT showed that 53 cases (94.64%) of coracoid bone masses were centered placed vertically, 2 cases (3.57%) were superior, and 1 case (1.79%) was inferior; 49 cases (87.50%) of the coracoid bone grafts were flush with the glenoid, 2 cases (3.57%) and 5 cases (8.93%) were medially and laterally positioned. The volume of coracoid bone graft decreased first and then increased, and the shape of the bone graft was continuously remodeling and gradually matched with the track of the humerus head (the optimal circle of the glenoid), all coracoid bone grafts healed. At last follow-up, the coverage rate of optimal glenoid circle was 89.6%-100%, with an average of 97.4%. The area of glenoid defect was 2.6%±1.3%, which significantly decreased when compared with preoperative (22.4%±5.4%) (P<0.05). At last follow-up, no obvious degenerative changes of shoulder joint was observed. ConclusionLU-tarjet procedure for recurrent anterior shoulder dislocation has good mid-term effectiveness with short operation time and few complications.

    Release date: Export PDF Favorites Scan
  • Histological properties of autogenous hamstring grafts after anterior cruciate ligament reconstruction

    ObjectiveTo investigate the histological characteristics of autogenous hamstring grafts after anterior cruciate ligament (ACL) reconstruction.MethodsThe patients who underwent arthroscopic single-bundle ACL reconstruction with autogenous hamstring tendons and were followed up at least 4 years and also underwent second-look arthroscopy between March 2017 and December 2017 and met the selection criteria were considered for enrollment. Graft quality under arthroscopy was evaluated as good remodeling group (GRG, the total scores were 4-6) and poor remodeling group (PRG, the total scores were 1-3) according to synovial and vascular coverage, the apparent tension of the grafts, the thickness and retear of the grafts. During the second-look arthroscopic procedures, ACL graft biopsies were performed. Normal ACL tissues harvested from the patients under 60 years old who underwent total knee arthroplasty were designated as normal controls. Graft vascularity, cellular morphology, cellular metabolism, and collagen fibril distribution were analyzed.ResultsThe 18 specimens (11 cases of GRG group and 7 cases of PRG group) and 9 native ACL biopsied tissue sample were enrolled into the study. Arthroscopy scores were 2-6 (mean, 4.7). The biology under light microscopy of GRG group was similar to that of native ACL in control group. There was no significant difference in the scores of graft vascularity and cellular morphology between GRG group and control group (P>0.05), while PRG group was significantly lower than the other two groups (P<0.05). Transmission electron microscope evaluation showed that GRG group and control group had better collagen fibril distribution and lower levels of cellular metabolism than PRG group (P<0.05). There was no significant difference in cellular metabolism between GRG and control groups (P>0.05), while collagen fibril distribution score of GRG group was significantly lower than that of control group (P<0.05).ConclusionWhile good remodeling grafts under arthroscopy in histological maturation period was proved to be more similar to normal ACL on ultrastructure properties under light and electron microscope, ultra structural differences regarding collagen fibril distribution still persist.

    Release date:2018-07-12 06:19 Export PDF Favorites Scan
  • A correlation study between the Mohawk expression level and the collagen fiber diameter of hamstring tendon graft after anterior cruciate ligament reconstruction

    ObjectiveTo evaluate the correlation between the Mohawk (MKX) expression level and the collagen fiber diameter of autologous hamstring tendon graft during the stable graft remodeling phase after anterior cruciate ligament (ACL) reconstruction.MethodsBetween January 2018 and August 2018, patients who underwent arth-roscopic single-bundle anatomical ACL reconstruction with autologous hamstring tendons for at least 48 months and also underwent second-look arthroscopy were enrolled in study. During the second-look arthroscopic procedures, ACL graft biopsies were performed from the surface of central part of the ligament. MKX expressions of ACL grafts were analysed by real-time fluorescent quantitative PCR (qRT-PCR). The ultrastructure of collagen fibers of grafts were evaluated by transmission electron microscopy, which included average diameter of collagen fibers (Dc), average diameter of large-diameter collagen fibers (DL), average diameter of small-diameter collagen fibers (DS), and large-small collagen fibers ratio (RL/S). The correlation between MKX expression level and graft collagen fiber diameter was calculated.ResultsTwenty-six patients met the selection criteria and their ACL graft specimens were enrolled in the study. The interval between ACL reconstruction and second-look arthroscopy was 52-128 months, with an average of 78.6 months. Arthroscopic graft remodeling score was 3-6 (mean, 4.8). There were 17 cases of excellent remodeling and 9 cases of fair remodeling. All ACL grafts showed typical bimodal distributions of both large-diameter collagen fibers and small-diameter collagen fibers, but the ultrastructural characteristics of the graft collagen fibers were different according to different remodeling status under arthroscopy. The DC, DL, DS, and RL/S of the graft specimens were (65.2±9.3) nm, (91.6±10.5) nm, (45.7±8.6) nm, and 0.73±0.12, respectively. The relative expression level of MKX was 1.42±0.11, which was positively linearly correlated with DC, DL, and RL/S, and the correlation coefficient was statistically significant (r=0.809, P=0.000; r=0.861, P=0.000; r=0.942, P=0.000), while there was no significant correlation between DS and relative expression level of MKX (r=0.147, P=0.238). Regression analysis showed that the relative expression level of MKX could predict the DC, DL, and RL/S results of the ACL graft specimens (P<0.05).ConclusionAfter autologous hamstring tendon grafts stepped into stabilized remodeling phase, MKX expression level could predict the diameter measurement results of collagen fibers and be used as an important evaluation basis for graft collagen anabolic metabolism.

    Release date:2019-08-23 01:54 Export PDF Favorites Scan
  • Effect of isokinetic training of thigh muscle group on graft remodeling after anterior cruciate ligament reconstruction

    ObjectiveTo investigate the effect of isokinetic training of thigh muscle group on graft remodeling after anterior cruciate ligament (ACL) reconstruction, and summarize the relevant rules to guide the clinic.MethodsBetween August 2016 and December 2016, forty patients underwent arthroscopic ACL reconstruction using hamstring tendon were randomly divided into isokinetic group and control group (n=20). The two groups of patients underwent staged rehabilitation treatment. The isokinetic group replaced the traditional intervention with the corresponding isokinetic strength training from 3 to 6 months after operation, and the traditional rehabilitation intervention was used in the control group. Finally, 12 cases of isokinetic group and 12 cases of control group with complete follow-up were enrolled in study. There was no significant difference in gender, age, body mass index, side of injury, the interval between injury and operation, and preoperative International Knee Documentation Committee (IKDC) score between the two groups (P>0.05). The peak torque (PT) of knee extension and flexion and hamstring quadriceps ratio (H/Q) were measured at 3 months, 6 months, 12 months, and the second-look arthroscopy. The MRI examination was performed at the same time to evaluate graft remodeling. The shape, tension, and degree of vascularization of grafts were observed under arthroscopy. The grafts were harvested and observed by HE staining.ResultsThe invertal between ACL reconstruction and the second-look arthroscopy was (23.57±3.23) months in isokinetic group and (23.22±3.56) months in control group, showing no significant difference between the two groups (P>0.05). At the second-look arthroscopy, the IKDC score was 90.45±4.73 in isokinetic group and 89.32±4.54 in control group, showing significant differences when compared with preoperative scores in the two groups (P<0.05). But there was no significant difference between the two groups (t=0.868, P=0.404). At 3 months after operation, there was no significant difference in the PT of knee extension and flexion between the two groups (P>0.05). At 6 months, 12 months, and the second-look arthroscopy, the PT of knee extension and flexion in isokinetic group were higher than those in control group (P<0.05). The H/Q at 6 months and 12 months were higher in isokinetic group than in control group, and the differences were significant (P<0.05). There was no significant difference in MRI score between the two groups at 3 months, 6 months, and the second-look arthroscopy (P>0.05). The MRI score at 12 months was significantly higher in isokinetic group than in control group (P<0.05). At the second-look arthroscopy, there was no significant difference in the arthroscopic score between the two groups (P>0.05), and the histological score of the isokinetic group was superior to the control group (P<0.05).ConclusionOn the basis of regular rehabilitation training, using the isokinetic training system to develop a suitable post-surgical isokinetic rehabilitation training program is helpful in early muscle strength recovery, early graft remodeling, and even long-term histological results after ACL reconstruction.

    Release date:2019-08-23 01:54 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content