  • Influence of valve height on the opening/closure performance of transplanted aortic valve

    Valve transplantation is often used in the treatment of aortic valve insufficiency. However, after surgery, the reconstructed aortic roots have an expansion phenomenon, in which the lack of valve height causes the aortic valve to close again. In this paper, the effects of different aortic valve height design on valve opening and closing performance were studied. The optimal surgical plan was obtained by in vitro numerical simulation, providing technical support and theoretical basis. In this paper, six groups of three-dimensional geometric models with a valve height increment of ± 0.5 mm were established with a root diameter of 26.0 mm and a valve height of 14.0 mm. Through the structural mechanics calculation and analysis of the parameters such as maximum stress, valve area and contact force of the model, reasonable geometrical dimensions are obtained. The study found that the maximum stress values of the six groups of models ranged from 640 to 690 kPa, which was consistent with the results of the literature; the three-group models with valve heights of 13.5 mm, 14.0 mm, and 14.5 mm were within a reasonable range. The contact force value of the 6 groups of leaflets increased with the increase of valve height. Studies have shown that the height of the aortic valve has an effect on the aortic valve closure performance. A valve height that is too small or too large will reduce the aortic systolic valve area and affect the aortic function.

    Release date:2019-04-15 05:31 Export PDF Favorites Scan
  • Effect of sinus diameter on the opening and closing performance of aortic valve under the expansion of aortic root

    This study aims to explore the effect of aortic sinus diameter on aortic valve opening and closing performance in the case of no obvious disease of aortic valve and annulus and continuous dilation of aortic root. A total of 25 three-dimensional aortic root models with different aortic sinus and root diameters were constructed according to the size of clinical surgical guidance. The valve sinus diameter DS is set to 32, 36, 40, 44 and 48 mm, respectively, and the aortic root diameter DA is set to 26, 27, 28, 29 and 30 mm, respectively. Through the structural mechanics calculation with the finite element software, the maximum stress, valve orifice area, contact force and other parameters of the model are analyzed to evaluate the valve opening and closing performance under the dilated state. The study found that aortic valve stenosis occurs when the DS = 32 mm, DA = 26, 27 mm and DS = 36 mm, DA = 26 mm. Aortic regurgitation occurs when the DS = 32, 36 and 40 mm, DA = 30 mm and DS = 44, 48 mm, DA = 29, 30 mm. The other 15 models had normal valve movement. The results showed that the size of the aortic sinus affected the opening and closing performance of the aortic valve. The smaller sinus diameter adapted with the larger root diameter and the larger sinus diameter adapted with the smaller root diameter. When the sinus diameter is 40 mm, the mechanical performance of the valve are good and it can well adapt with the relatively large range of aortic root dilation.

    Release date:2019-12-17 10:44 Export PDF Favorites Scan
  • Experimental study of the effects of sinotubular junction taper on artificial bioprosthesis valve in pulsatile flow condition

    The aim of the present experimental study is to determine the effects of sinotubular junction diameter on artificial bioprosthesis valves. An experimental study was performed for aortic root models with different sinotubular junction taper under pulsatile flow condition. The sinotubular junction diameters were modified to create four models with different sinotubular junction tapers with 0, 1, 3 and 5 degrees, respectively, using three dimensional printing techniques. After installing the testing bioprosthesis valve on the aortic root models, we conducted experiments of the pulsatile flow testing with different stroke volume in the pulsatile circulation simulation system. The testing condition was set at the pulse frequency of 70 beats/min and the stroke volume of 2–7 L/min. The status of the valves in 10 continuous pulse cycles was tested and the average results were obtained for each stroke volume. The results of testing showed that the mean transvalvular pressure gradients agreed well with the national standard, and all smaller than 10 mm Hg. The sinotubular junction taper had an influence on regurgitation fraction of the artificial bioprosthesis valve. The smaller sinotubular junction taper showed beneficial effect to decrease the regurgitation fraction. In the case of smaller stroke volume, the smaller sinotubular junction taper was beneficial to increase the effective valve orifice area. In the case of larger stroke volume, the larger sinotubular junction taper was beneficial to increase the effective valve orifice area. This study indicates that a doctor should consider the smaller sinotubular junction taper in the case of smaller stroke volume more. In the case of larger stroke volume, the doctor should consider the larger sinotubular junction taper more.

    Release date:2017-06-19 03:24 Export PDF Favorites Scan