west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "Patellar tendon" 3 results
  • MANAGEMENT OF INFERIOR POLAR COMMINUTED FRACTURES OF PATELLA AND PATELLAR TENDON INJURY

    Objective To investigate the treatment and effectiveness of inferior polar comminuted fractures of patella and patellar tendon injury. Methods Between January 2003 and December 2008, 5 patients with inferior polar comminuted fractures of patella and patellar tendon injury were treated with Nitinol Patellar Concentrator and fascia lata allograft. There were 3 males and 2 females with a mean age of 33.7 years (range, 20-48 years). The interval of injury and operation was 1-5 days. Fracture degree: 3 cases had 3 fractures of patella, 2 cases had 4 fractures; patellar tendon injury degree: 3cases had horizontal rupture of middle l igament, 1 case had obl ique rupture of tibial tubercle, and 1 case had longitudinal partial rupture. Results Heal ing of incision by first intention was achieved in all patients, and no compl ication of infection or deep venous thrombosis occurred. The X-ray films at 2 days after surgery showed that patella recovered to normal height, which meaned ratio of patella height to patellar tendon length recovered to 1 : 1. Five cases were followed up 18 months on average (range, 10-22 months). At 3-12 weeks after surgery, the knee function of the injury side almost reached that of the normal side in 4 patients, and the knee range of motion was about 100° in 1 patient. The fracture heal ing time was 3-5 months. At 12-15 months after surgery, patella holder was taken out and no lost of reduction or refracture occurred. During follow-up, there was no fracture displacement, loosening and breakage of implant, or rerupture of patellar tendon. According to ZHANG Chuncai’ s criterion for knee joint function, the results were excellent in 3 cases, good in 1 cases, and fair in 1 case with an excellent and good rate of 80%. According to XU Shaoting’s criterion for knee joint function, the results were excellent in 2 cases, good in 2 cases, and fair in 1 case with an excellent and good rate of 80%. Conclusion Nitinol Patellar Concentrator and fascia lata allograft is a new method to treat inferior polar comminuted fractures of patella and patellar tendon injury, and it can ensure the knee joint stabil ity in early motion after surgery.

    Release date:2016-08-31 05:44 Export PDF Favorites Scan
  • RECONSTRUCTION OF ANTERIOR CRUCIATE LIGAMENT WITH DIFFERENT GRAFTS UNDER ARTHROSCOPE IN 68 CASES

    Objective To study the clinical effect of anterior cruciate ligament(ACL) reconstruction with different grafts under arthroscope. Methods A retrospective analysis was done on 68 cases of ACL injury.ACL reconstruction with bonepatellar tendonbone autograft and interface screw fixation were performed in 26 cases(group A) and quadruple semitendinosus tendon autograft and endobutton plate fixationin in 38 cases (group B). ACL reconstruction with bonepatellar tendonbone allograft cryopreserved and interface screw fixation were performed in 4 cases (group C). Therewere 16 males and 10 females with an average age of 26.4 years (16-45 years) in group A, 24 males and 14 females with an average age of 24.6 years (13-48 years) in group B, and 3 males and 1 female (55-65 years) in group C. The left knee involved in 14 cases, 27 cases and 3 cases, and the right knee involved in 12 cases, 11 cases and 1 case in groups A, B and C, respectively. The disease courses were 1 week to 15 months (group A), 1 week to 16 months (group B) and 2 weeksto 28 months (group C).The intermediate myodynamic recovery, IKDC score and Lysholm score were compared among 3 groups. Results All patients were followed 12-36 months (17.5 months in group A, 18.5 months in group B and 16.5 months in group C). No intra articular infection, phlebothrombosis of leg, vascular injury and nerve injury occurred. Lysholm scores was increased from preoperative 65.3±4.8 to postoperative 95.1±4.3 in group A, from 68.4±5.6 to 93.0±5.9 in group B and from 60.3±6.7 to 92.2±4.3(excellent in 3 cases and good in 1 case) in group C; the excellent and good rates were 88.5% (excellent in 18 cases, good in 5 cases and fair in 3 cases) in group A, 86.8% (excellent in 28 cases, good in 5 cases and fair in 5 cases) in group B, IKDC scores were 93.7±3.8 (group A), 95.7±4.7 (group B) and 94.8±3.6(group C); the knee joint functions were normal in 19 cases(73.1%), in 30 cases (78.9%) and in 3 cases, were fair in 5 cases (19.2%), in 5 cases (13.2%) and in 1 cases in groups A, B and C respectively. Conclusion The transplantation of bonepatellar tendonbone autograft , quadruple semitendinosustendon autograft and bonepatellar tendonbone allograft all can reconstruct and strengthen the stability of knee joint. Bonepatellar tendonbone allograft is better selection for the ACL injury in elder and quadruple semitendinosus tendon autograft is suitable to adolescent patients with disrupted ACL.

    Release date:2016-09-01 09:20 Export PDF Favorites Scan
  • MORPHOLOGICAL CHARACTERISTIC AND BIOCOMPATIBILITY EVALUATION OF POROUS TANTALUM IMPLANTED INTO RABBIT PATELLAR TENDON

    ObjectiveTo observe the morphological characteristic by implanting domestic porous tantalum in rabbit patellar tendon and to evaluate biocompatibility features so as to provide experimental basis for porous tantalum used as interface fixation between tendon and bone. MethodsA total of 48 adult New Zealand white rabbits, male or female, weighing 2.5-3.0 kg, were selected. Porous tantalum flake (5 mm×5 mm×2 mm) was implanted in the left patellar tendon (experimental group) and the same size porous titanium flake in the right patellar tendon (control group). The animals were sacrificed at 2, 4, 8, and 12 weeks after implantation, then the specimens were harvested for gross observation, HE staining, scanning electron microscope (SEM) observation, and hard slices observation. ResultsNo animal died after operation. Porous tantalum was bonded closely with host tendon and no inflammatory reaction was found. Loose and thick fibrous capsule was observed at the beginning and became density and thinner in the end by microscope, showing significant difference between different time points in 2 groups (P<0.05), but no significant difference was found between 2 groups at different time points (P>0.05). The SEM observation showed that fibrous tissue attached to the surface and inner walls of porous tantalum at early stage, and extended on the material to reach confluence at late period, but the experimental group was more than the control group. Hard slices observation showed that the collagen fibrils were seen on porous tantalum interface with host tendon, and blood vessels grew into the pores. The control group and the experimental group showed no significant difference. ConclusionThe domestic porous tantalum has good biocompatibility. Connection and integration can be established between tendon and porous tantalum, and therefore it could be used in reconstruction of tendon-bone fixation device.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content