Objective To evaluate the effect of internal fixation on the stability of pedicled fascial flap and the osteogenesis of exceed critical size defect (ECSD) of bone so as to provide theory for the clinical application by the radiography and histology observation. Methods The ECSD model of the right ulnar midshaft bone and periosteum defect of 1 cm in length was established in 32 New Zealand white rabbits (aged 4-5 months), which were divided into group A and group B randomly (16 rabbits in each group). The composite tissue engineered bone was prepared by seeding autologous red bone marrow (ARBM) on osteoinductive absorbing material (OAM) containing bone morphogenetic protein and was used repair bone defect. A pedicled fascial flap being close to the bone defect area was prepared to wrap the bone defect in group A (control group). Titanium miniplate internal fixation was used after defect was repair with composite tissue engineered bone and pedicled fascial flap in group B (experimental group). At 2, 4, 6, and 8 weeks, the X-ray films examination, morphology observation, and histology examination were performed; and the imaging 4-score scoring method and the bone morphometry analysis was carried out. Results All rabbits survived at the end of experiment. By X-ray film observation, group B was superior to group A in the bone texture, the space between the bone ends, the radiographic changes of material absorption and degradation, osteogenesis, diaphysis structure formation, medullary cavity recanalization. The radiographic scores of group B were significantly higher than those of group A at different time points after operation (P lt; 0.05). By morphology and histology observation, group B was superior to group A in fascial flap stability, tissue engineered bone absorption and substitution rate, external callus formation, the quantity and distribution area of new cartilage cells and mature bone cells, and bone formation such as bone trabecula construction, mature lamellar bone formation, and marrow cavity recanalization. The quantitative ratio of bone morphometry analysis in the repair area of group B were significantly larger than those of group A at different time points after operation (P lt; 0.05). Conclusion The stability of the membrane structure and the bone defect area can be improved after the internal fixation, which can accelerate bone regeneration rate of the tissue engineered bone, shorten period of bone defect repair, and improve the bone quality.
Objective To compare the effect between vascularization osteogenesis and membrane guided osteogenesis in the bone repair by the tissue engineered bone with pedicled fascial flap packing autologous red bone marrow (ARBM), so as to provide a reference for the bone defect repair in cl inic. Methods The tissue engineered bone was constructed with ARBM and the osteoinductive absorbing recombinant human materials with recombinant human bone morphogenetic protein 2. Sixty New Zealand rabbits (aged 4-5 months, weighing 2.0-2.5 kg) were randomly divided into group A (n=16), group B (n=22), and group C (n=22). The complete periosteum defect model of 1.5 cm in length was prepared in right ulnar bone, then the tissue engineered bone was implanted in the bone defect area in group A, the tissue engineered bonewith free fascial flap in group B, and the tissue engineered bone with pedicled fascial flap in group C. At 4, 8, 12, and 16 weeks, the tissue of bone defect area was harvested from 4 rabbits of each group for the general, histological, and immunohistochemical staining observations; at 8, 12, and 16 weeks, 2 rabbits of groups B and C, respectively were selected to perform ink perfusion experiment by axillary artery. Results The general observation showed that the periosteum-l ike tissues formed in the fascial flap of groups B and C, chondroid tissues formed in group B, new bone formed in group C, and the fibrous and connective tissues in group A at 4 and 8 weeks; a few porosis was seen in group A, more new bone in group B, and bone stump formation in group C at 12 and 16 weeks. Histological observation showed that there were few new blood vessels and new bone trabeculae in groups A and B, while there were large amounts of new blood vessels and mature bone trabeculae in group C at 4 and 8 weeks. There were a few new blood vessels and new bone trabeculae in group A; more blood vessels, significantly increased mature trabeculae, and the medullary cavity formation in group B; and gradually decreased blood vessels, the mature bone structure formation, and the re-opened medullary cavity in group C at 12 and 16 weeks. The immunohistochemical staining observation showed that the levels of CD105, CD34, and factor VIII were higher in group C than in groups A and B at different time points.The bone morphometry analysis showed that the trabecular volume increased gradually with time in 3 groups after operation; the trabecular volume in group C was significantly more than those in groups A and B at different time points (P lt; 0.05); and there was significant difference between groups A and B (P lt; 0.05) except the volume at 4 weeks (P gt; 0.05). The vascular image analysis showed that the vascular regenerative area ratio in group C was significantly higher than those in groups A and B at different time points (P lt; 0.05). The ink perfusion experiment showed that the osteogenic zone had sparse ink area with no obvious change in group B, while the osteogenic zone had more intensive ink area and reached the peak at 8 weeks, then decreased in group C. Conclusion The tissue engineered bone with pedicled fascial flap packing ARBM has the vascularization osteogenesis effect at early stage, but the effect disappears at late stage gradually when the membrane guided osteogenesis is main.
Objective To investigate the effect of repairing bone defect with tissue engineered bone seeded with the autologous red bone marrow (ARBM) and wrapped by the pedicled fascial flap and provide experimental foundation for cl inicalappl ication. Methods Thirty-two New Zealand white rabbits (male and/or female) aged 4-5 months old and weighing2.0-2.5 kg were used to make the experimental model of bilateral 2 cm defect of the long bone and the periosteum in the radius. The tissue engineered bone was prepared by seeding the ARBM obtained from the rabbits on the osteoinductive absorbing material containing BMP. The left side of the experimental model underwent the implantation of autologous tissue engineered bone serving as the control group (group A). While the right side was designed as the experimental group (group B), one 5 cm × 3 cm fascial flap pedicled on the nameless blood vessel along with its capillary network adjacent to the bone defect was prepared using microsurgical technology, and the autologous tissue engineered bone wrapped by the fascial flap was used to fill the bone defect. At 4, 8, 12, and 16 weeks after operation, X-ray exam, absorbance (A) value test, gross morphology and histology observation, morphology quantitative analysis of bone in the reparative area, vascular image analysis on the boundary area were conducted. Results X-ray films, gross morphology observation, and histology observation: group B was superior to group A in terms of the growth of blood vessel into the implant, the quantity and the speed of the bone trabecula and the cartilage tissue formation, the development of mature bone structure, the remolding of shaft structure, the reopen of marrow cavity, and the absorbance and degradation of the implant. A value: there was significant difference between two groups 8, 12, and 16 weeks after operation (P lt; 0.05), and there were significant differences among those three time points in groups A and B (P lt; 0.05). For the ratio of neonatal trabecula area to the total reparative area, there were significant differences between two groups 4, 8, 12, and 16 weeks after operation (P lt; 0.05), and there were significant differences among those four time points in group B (P lt; 0.05).For the vascular regenerative area in per unit area of the junctional zone, group B was superior to group A 4, 8, 12, and 16 weeks after operation (P lt; 0.05). Conclusion Tissue engineered bone, seeded with the ARBM and wrapped by the pedicled fascial flap, has a sound reparative effect on bone defect due to its dual role of constructing vascularization and inducing membrane guided tissue regeneration.