  • RECONSTRUCTION OF PELVIC RING WITH MINIMALLY INVASIVE PLATE FIXATION

    Objective To investigate the effectiveness of minimally invasive plate fixation in treatment of unstable pelvic fractures. Methods Between May 2006 and December 2009, 21 patients with unstable pelvic fractures were treated. There were 13 males and 8 females with an average age of 39 years (range, 21-66 years). The causes of injury included traffic accident in 9 cases, falling from height in 6 cases, and heavy pound injury in 6 cases. The time from injury to hospitalization was 1 to 4 hours with an average of 2.8 hours. According to Tile’s classification, there were 12 cases of type B and 9 cases of type C. After admission, bone traction and exo fixation were performed, and minimally invasive plate fixation was given at 5-24 days after injury. Results All incisions healed by first intention, and no complications of nerve and vessel injuries occurred. According to the reduction criteria of Matta radiography, anatomic reduction was achieved in 16 cases, satisfactory reduction in 4 cases, and fair reduction in 1 case. All patients were followed up 12 months. The X-ray films showed all fractures healed at 2-4 months (mean, 2.6 months). According to Majeed clinical evaluation, the results were excellent in 12 cases, good in 7 cases, and fair in 2 cases. Conclusion Minimally invasive plate fixation can provide effective fixation, reconstruct pelvic ring, and reduce perioperative complications in the treatment of unstable pelvic fractures.

    Release date:2016-08-31 05:45 Export PDF Favorites Scan
  • MINIMALLY-INVASIVE LOCKING COMPRESSION PLATE TO TREAT COMPLEX HUMERAL SHAFT FRACTURE

    Objective To investigate an effect of the minimally-invasive locking compression plate (LCP) under the anterior humeral approach to treat the complex humeral shaft fracture. MethodsEleven patients (6 males, 5 females; age, 3266 years) with a humeral shaft fracture were treated with the minimally-invasive LCP under the modified anterior humeral approach from March 2005 to February 2006. Five of the patients were injured in a traffic accident and the remaining 6 were wounded in a fall. All the patients had an unstable fracture. The multiple segment fracture was found in 2 patients, the obligue line fracture in 1 patient, and the long segment comminuted fracture in 8 patients, of whom the radial nerve injury was found in 1 patient, who had an emergency treatment by the loosening of the radial nerve and the internally fixing with LCP. As for the fracture site, the middle and/or the upper-part fracture of the humerus was found in6 patients, and the middle and/or lower-part fracture of the humerus was foundin 5 patients. The patients underwent the operation in the period from 48 hours to 4 days after the injuries. Results All the patients had a complete healing of their fractures 2-4 months after operation. One patient underwent the loosening of the radial nerve and the internally-fixing with LCP, and his function recovered 3 days after operation.The follow-up for 6-12 months revealed that all the patients’ function recovered. According to the Neer Scoring System for the shoulder function evaluation, 7 patients had an excellent result, 3 had a good result, and 1 had a fair result. According to the HSS Scoring System, 9 patients had an excellent result and 2 had a good result. Conclusion The minimally-invasive locking compression plate under the anterior humeral approach to treat the complex humeral shaft fracture is an effective and safe method of treating the complex humeral shaft fracture.

    Release date:2016-09-01 09:23 Export PDF Favorites Scan
  • EARLY OUTCOME OF DIFFERENT OPERATION METHODS IN TREATMENT OF MULTI-SEGMENTAL CERVICAL SPONDYLOTIC MYELOPATHY

    ObjectiveTo explore the early outcome of 3 different operation methods in the treatment of multi-segmental cervical spondylotic myelopathy (CSM). MethodsA retrospective analysis was made on the clinical data of 74 patients with multi-segmental CSM treated between January 2011 and March 2013. The patients were divided into 3 groups according to operation methods:open-door expansive laminoplasty by plate was used in 21 patients (group A), open-door expansive laminoplasty by anchor fixation in 28 patients (group B), and conventional unilaterally open-door expansive laminoplasty in 25 patients (group C). There was no significant difference in gender, age, disease druation, affected segments, preoperative Japanese Orthopaedic Association (JOA) score, and cervical curvature of C2-7 among 3 groups (P > 0.05). The peration time, intraoperative blood loss, and JOA score, cervical curvature, incidence of axial symptoms were recorded. ResultsThere was no significant difference of operation time and intraoperative blood loss between group A and group B (P > 0.05). All incisions healed by first intention. Cerebrospinal leak occurred in 2 cases (1 case of group B and 1 case of group C) and C5 nerve root palsy in 4 cases (2 cases of group A, 1 case of group B, and 1 case of group C); all the symptoms disappeared after symptomatic treatment. The patients were followed up 12-39 months (mean, 18.3 months). The position of internal fixation was good without loosening and pulling out in groups A and B. Reclosed open-door was observed in 2 cases of group C, which disappeared after the second surgery. The JOA scores were significantly increased at 6 months after operation when compared with preoperative scores in groups A, B, and C (P < 0.05). The cervical curvature of C2-7 at postoperation was significantly improved when compared with preoperative one in groups B and C (P < 0.05) except group A (P > 0.05). There were significant differences in JOA score and the cervical curvature among 3 groups at 6 months after operation (P < 0.05). The incidence of axial symptoms were 4.76% (1/21), 35.71% (10/28), and 72.00% (18/25) in groups A, B, and C respectively, showing significant differences (P < 0.017). ConclusionOpen-door expansive laminoplasty by plate has better early outcome than open-door expansive laminoplasty by anchor fixation and conventional unilaterally open-door expansive laminoplasty in the treatment of multi-segmental CSM.

    Release date: Export PDF Favorites Scan
  • BIOMECHANICAL IMPACT OF OBLIQUE LOCKING PLATE ON FIXATION OF FEMORAL SHAFT FRACTURES

    ObjectiveTo investigate the biomechanical influence of the oblique locking plate on the fixation of femoral shaft fracture. MethodsForty imitation artificial femur model with mechanical properties similar to human femur were selected and randomly divided into groups A, B, C, and D, 10 in each group; the femur fracture model was made by transverse osteotomy at 15 cm and 17 cm below the lesser trochanter of the femur and fixed with locking plate with 12 holes and cortical bone screws. The plate was placed in the middle of the longitudinal axis of the femur in group A, and was placed at 5, 10, and 15° angle axis in groups B, C, and D respectively. The axial compression, three-point bending, torsion tests were carried out to measure the strain. ResultsWith the compressive load and bending load increasing, the medial and lateral strains were significantly increased in each group (P<0.05); but no significant difference was found in strains under compressive load and bending load among 4 groups (P>0.05). With increasing torque, the strain was significantly increased in each group (P<0.05). At 10 N·m torque, there was no significant difference in the strain values among 4 groups (P>0.05); the strain value was significantly higher in groups C and D than groups A and B (P<0.05) and in group D than group C (P<0.05) at torque of 20 and 50 N·m, but no significant difference was found between groups A and B (P>0.05). ConclusionUnder different stress, the strain will be significantly increased when the plate is placed at >10° angle axis.

    Release date: Export PDF Favorites Scan
  • Efficacy of Percutaneous Cannulated Screw versus Plate Fixation for Ankle Fractures: A Meta-analysis

    ObjectiveTo systematically review the efficacy of percutaneous cannulated screw (PCS) versus plate fixation (PF) in the treatment of ankle fractures. MethodsThe Cochrane Library (Issue 5, 2014), PubMed, EMbase, CBM, CNKI, VIP and WanFang Data were searched up to May 28th 2014, for studies concerning the efficacy of percutaneous cannulated screw versus plate fixation for ankle fractures. Two reviewers independently screened literature according to the inclusion and exclusion criteria, extracted data and assessed the methodological quality of included studies. Then, meta-analysis was performed by using RevMan 5.1 software. Result A total of 10 studies (3 RCTs and 7 CCTs) involving 627 patients were included. The results of meta-analysis showed that:compared with the PF group, the PCS group was superior in time of the operation (RCT:MD=-6.78, 95%CI -11.95 to -1.60, P=0.01; CCT:MD=-9.76, 95%CI -13.68 to -5.84, P<0.000 01), blood loss during the operation (RCT:MD=-36.14, 95%CI -40.02 to -32.17, P<0.000 01; CCT:MD=-34.80, 95%CI -37.78 to -31.81, P<0.000 01) and the time of the fracture healing (RCT:MD=-1.16, 95%CI -1.51 to -0.81, P<0.000 01; CCT:MD=-1.55, 95%CI -2.97 to -0.13, P=0.03); However, there were no statistical differences between the two groups in complication rate (CCT:OR=0.48, 95%CI 0.08 to 2.81, P=0.41), AOFAS score excellent rate (RCT:OR=2.11, 95%CI 0.81 to 5.49, P=0.12; CCT:OR=1.58, 95%CI 0.75 to 3.30, P=0.23), and postoperative malleolus pain rate (CCT:OR=0.68, 95%CI 0.00 to 148.82, P=0.89). ConclusionCurrent evidence shows that PCS is superior to PF in shorting time of the operation, reducing blood loss during the operation, and shorting time of the fracture healing. However, the complication rate, AOFAS score excellent rate, and postoperative malleolus pain rate are similar for each operation. Due to the quality limitation of the CCTs, the conclusion are needed to be verified by more high quality RCTs in future.