west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "QINMin" 2 results
  • Application of Continuous Quality Improvement Measures in Prevention of Peritoneal Dialysis Related Peritonitis

    ObjectiveTo investigate whether continuous quality improvement (CQI) measures can reduce the episodes of peritonitis. MethodsWe analyzed the data of 114 cases of peritoneal dialysis related peritonitis from January to December 2011 before applying CQI measures and 72 cases from January and December 2012 after applying CQI measures in West China Hospital. Then we studied the episodes, cause and pathogenic bacteria species of peritonitis in peritoneal dialysis patients. We implemented the process of reducing the episodes of peritonitis by applying PDCA four-step design: plan-do-check-act. ResultsThe episodes of peritonitis were reduced from per 60.8 patient-months (0.197/patient-years) to per 66.6 patient-months (0.180/patient-years) after applying CQI measures. The positive rate of pathogenic bacteria culture was both 50.0% before and after applying CQI measures, in which 66.7% were gram-positive cocci. The curing rate of peritonitis was increased from 57 case/times (76.3%) to 87 case/times (79.2%). Switching to hemodialysis rate was reduced from 17 cases/times (14.9%) to 10 cases/times (13.9%). Death cases was reduced from 9 cases/times (7.9%) to 5 cases/times (6.9%). ConclusionThese results show that the incidence of peritoneal dialysis related peritonitis decreases and the curing rate increases through CQI measures.

    Release date: Export PDF Favorites Scan
  • Application of Continuous Quality Improvement in Laparoscopic Peritoneal Dialysis Catheter Input

    ObjectiveTo reduce the incidence of peritoneal dialysis (PD) catheter complications through a continuous quality improvement (CQI) process. MethodsTwenty-nine patients with catheters inserted (from January 2011 to March 2011) before CQI, and another 41 patients with catheters inserted (between April 2011 and January 2012) after CQI were observed and analyzed. The possible causes of complications of catheter were summarized, and then on the basis of that, a PDCA four-step (plan-do-check-act) method was designed with a view to reducing the incidence of postoperative complications. ResultsPD catheter dysfunction decreased from 6.90% to 2.44%. The incidence of leakage decreased from 44.83% to 9.76%. ConclusionCQI is a useful method to reduce the incidence of postoperative complications of PD catheter in peritoneal dialysis.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content