west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "QU Guoxin" 2 results
  • Effectiveness evaluation of three-dimensional printed titanium-alloy prosthesis reconstruction after distal tibia tumor segment resection

    Objective To evaluate the feasibility and short-term effectiveness of three-dimensional (3D) printed titanium-alloy prosthesis reconstruction after the distal tibia tumor segment resection. Methods The clinical data of 6 patients with bone defect after distal tibia tumor segment resection treated with 3D printed titanium-alloy prosthesis reconstruction and tibiotalar joint fusion between January 2020 and December 2021 were retrospectively analyzed. There were 2 males and 4 females; the age ranged from 12 to 35 years, with an average of 18.5 years. Among them, 4 cases were osteosarcoma, 1 case was Ewing sarcoma, and 1 case was giant cell tumor of bone. The Enneking staging was stage ⅡA in 3 cases, stage ⅡB in 2 cases, and stage Ⅲ in 1 case. The disease duration was 2-5 months (mean, 3.2 months). All patients received preoperative neoadjuvant therapy, and patients with osteosarcoma and Ewing sarcoma started chemotherapy at3 weeks after operation. The systemic and local tumor conditions and prosthesis conditions were evaluated regularly after operation. The Musculoskeletal Tumor Society (MSTS) score and the American Orthopaedic Foot and Ankle Society (AOFAS) score were used to evaluate the lower extremity and ankle function. Results All patients were followed up 8-26 months, with an average of 15.6 months. There was no local recurrence and distant metastasis during the follow-up. The ankle joints of 5 cases were all in 90° functional position at last follow-up, and there was no complication such as prosthesis loosening and fracture; the ankle joint fusion was stable, the local bone ingrowth was good, and the daily activities could be completed, but the ankle range of motion was limited and the ankle joint was stiff. The MSTS score ranged from 22 to 26, with an average of 24, and 3 cases were evaluated as excellent and 2 cases were good; the AOFAS score ranged from 71 to 86, with an average of 80.6, and 4 cases were evaluated as good and 1 case was fair. One patient had severe periprosthetic infection at 2 months after operation, resulting in failure of prosthesis implantation, pain in limb movement, and poor ankle function; MSTS score was 12, AOFAS score was 50, and both were evaluated as poor; distraction osteogenesis was performed after removal of prosthesis and infection control, at present, it was still in the process of distraction osteogenesis, and local osteogenesis was acceptable. Conclusion Using 3D printed titanium-alloy prosthesis and tibiotalar joint fusion to reconstruct the bone defect after distal tibia tumor segment resection has satisfactory mechanical stability and function, and is one of the effective distal tibial limb salvage methods.

    Release date: Export PDF Favorites Scan
  • Application of three-dimensional printed customized prosthesis with preserved epiphysis and articular surface in the reconstruction of large bone defects in treatment of adolescent femoral malignant tumors

    Objective To investigate the clinical application and effectiveness of three-dimensional (3D) printed customized prosthesis with preserved epiphysis and articular surface in the reconstruction of large bone defects in treatment of adolescent femoral malignant tumors. Methods The clinical data of 10 adolescent patients with femoral primary malignant tumor who met the selection criteria and underwent limb salvage surgery with 3D printed customized prosthesis with preserved epiphysis and articular surface between January 2020 and October 2021 were retrospectively analyzed. There were 6 males and 4 females with an average age of 12.5 years ranging from 7 to 18 years. There were 8 cases of osteosarcoma and 2 cases of Ewing’s sarcoma. Enneking stage was Ⅱb. The length of the lesions ranged from 76 to 240 mm, with an average of 138.0 mm. The length of osteotomy (i. e. length of customized prosthesis) ranged from 130 to 275 mm, with an average of 198.5 mm; the distance between distal osteotomy end and epiphyseal line ranged from 0 to 15 mm, with an average of 8.8 mm; the bone defect after osteotomy accounted for 37.36% to 79.02% of the total length of the lesion bone, with a mean of 49.43%. The operation time, intraoperative blood loss, complications, tumor outcome (refered to RESIST1.1 solid tumor efficacy evaluation criteria), and limb length discrepancy were recorded. The Musculoskeletal Cancer Society (MSTS) 93 score was used to evaluate the function at 6 months after operation, and visual analogue scale (VAS) score was used to evaluate the pain before and after operation. Results The operation was successfully performed in all the 10 patients, and the postoperative pathological results were consistent with the preoperative pathological results. The operation time was 165-440 minutes, with an average of 263 minutes; and the intraoperative blood loss was 100-800 mL, with an average of 350 mL. All patients were followed up 7-26 months, with an average of 11.8 months. No tumor was found on the osteotomy surface; the customized prosthesis were firmly installed and closely matched with the retained articular surface. The tumor outcome of neoadjuvant chemotherapy was stable in 4 cases and partial remission in 6 cases. No local recurrence or distant metastasis was found in 9 cases after postoperative adjuvant chemotherapy; pulmonary metastasis was found in 1 case at 12 months after operation. Two patients had local incision fat liquefaction, superficial infection, and delayed healing at 14 days after operation; 1 patient had local bone absorption at the contact surface of the prosthesis, and the screw and prosthesis did not loosen at 7 months after operation; the other patients had good incision healing, with no infection, prosthesis loosening, fracture, or other complications. At 6 months after operation, the MSTS93 score was 19-28, with an average of 24.1; 8 cases were excellent and 2 cases were good. The VAS score was 0.9±1.0, which significantly improved when compared with before operation (5.9±1.0) (t=23.717, P<0.001). The height of the patients increased by 1-12 cm, with an average of 4.6 cm. At last follow-up, 4 patients had limb length discrepancy, with a length difference of 1 cm in 2 cases and 2 cm in 2 cases. Conclusion The application of 3D printed customized prosthesis in the resection and reconstruction of adolescents femoral primary malignant tumors can achieve the purpose of preserving epiphysis and articular surface, and obtain good effectiveness.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content