west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "Residue" 2 results
  • METHOD OF RESIDUE ASSAY OF CROSSLINKING AGENT IN CROSS-LINKED SODIUM HYALURONIC GEL

    ObjectiveTo establish a more accurately method to detect the residue of 1,4-butanediol diglycidyl-ether (BDDE) in the cross-linked sodium hyaluronic gel so as to provide a scientific testing method for the quality control. MethodsThe gas chromatography was used to explore the thermal stability of BDDE, and the residues of BDDE in sodium hyaluronic gel was detected by fluorescence spectrophotometry. The hyaluronidase was added to the BDDE standard solution and the improved fluorescence spectrophotometer was used to detect the BDDE residues in the cross-linked hyaluronic sodium gel. ResultsA good linearity was obtained as y=14.102x+1.103 (R2=0.999 8) for BDDE. BDDE was unstable under high temperature and long storage time. The relevant fluorescence intensity was detected with hyaluronidase solution. After adding hyaluronidase into the BDDE standard solutions, the advanced linearity was obtained as y=14.027x+7.062 (R2=0.999 9). ConclusionFluorescent spectrophotometry is a simple, rapid, and accurate method to analyze BDDE residue of cross-linked sodium hyaluronic gel. Due to the poor thermal stability, all the factors related to temperature must be excluded during the process, including the temperature control of every step. Furthermore, the adding of hyaluronidase in the pre-preparation of cross-linked sodium hyaluronic gel can bring interference. So when using fluorescent spectrophotometry, adjustment must be taken before the calibration curve is preparation.

    Release date: Export PDF Favorites Scan
  • Value of Intra-operative Ultrasound in Diagnosis of Tumor Residue after Resection of Intracranial Gliomas: A Meta-Analysis

    ObjectiveTo systematically review the value of intra-operative ultrasound in diagnosis of tumor residue after resection of intracranial gliomas. MethodsSuch databases as PubMed, EMbase, The Cochrane Library, CBM, CNKI, WanFang Data and VIP were electronically searched for the diagnostic test about intra-operative ultrasound in diagnosis of tumor residue after resection of intracranial gliomas by March 31st, 2013. Meanwhile, search engines such as Google, Baidu were also used for relevant search. According to the inclusion and exclusion criteria, the literature was screened and the data were extracted. The methodological quality was evaluated in accordance with the quality assessment tool for diagnostic accuracy studies (QUADAS) and then meta-analysis was conducted using Meta-DiSc 1.4 software. ResultsA total of 10 studies involving 423 patients were included. The results of meta-analysis showed that the sensitivity, specificity, positive likelihood ratio, negative likelihood ratio and diagnostic odds ratio (DOR) were 0.78 (95%CI 0.74 to 0.82), 0.90 (95%CI 0.88 to 0.90), 5.12 (95%CI 2.86 to 9.16), 0.29 (95%CI 0.21 to 0.39) and 25.00 95%CI (13.27 to 47.10), respectively; and the AUC was 0.89. In the subgroup analysis, for low grade intracranial gliomas, the results of meta-analysis showed that the sensitivity, specificity and DOR were 0.87 (95%CI 0.77 to 0.94), 0.88 (95%CI 0.78 to 0.94) and 28.93 (95%CI 7.46 to 112.14), respectively, and the AUC was 0.92. For high grade gliomas, the results of meta-analysis showed that the sensitivity, specificity and DOR were 0.80 (95%CI 0.72 to 0.87), 0.67 (95%CI 0.53 to 0.79) and 7.20 (95%CI 3.04 to 17.09), respectively, and the AUC was 0.80. ConclusionIntra-operative ultrasound is useful for the diagnosis of tumor residue after resection of intracranial gliomas, especially for low grade gliomas.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content