Objective To investigate clinical diagnosis,timing of surgery and perioperative therapeutic strategies for blood culture-negative infective endocarditis (IE). Methods Clinical data of 240 IE patients who were admitted tWuhan Asia Heart Hospital between July 2008 and July 2012 were retrospectively analyzed. According to their blood cultureresults,all the patients were divided into blood culture-negative group and blood culture-positive group. In the blood culture-negative group,there were 158 patients including 88 male and 70 female patients with their age of 51.3±10.1 years. In the blood culture-positive group,there were 82 patients including 45 male and 37 female patients with their age of 48.9±9.8 years. All the patients underwent surgical treatment,and the surgical procedures included complete vegetations excision,debridement of infected valves,removal of necrotic tissue around the annulus,and concomitant heart valve replacement or intracardiac repair. Postoperatively,all the patients received routine monitoring in ICU,cardiac glycosides,diuretics,other symptomatic treatment and adequate dosages of antibiotics for 4-6 weeks. Results Four patients died postoperatively in this study including 1 patient for low cardiac output syndrome and 3 patients for multiple organ dysfunction syndrome,1 patient in the blood culture-positive group and 3 patients in the blood culture-negative group respectively. There was no statistical difference in surgical mortality between the 2 groups (χ2=0.15,P=0.70). All the other patients were discharged successfully and followed up for 6 to 36 months with the median follow-up time of 22 months. During follow-up, 2 patients died including 1 patient for cerebral infarction 2 years after surgery and another patient for cerebral hemorrhage 3 yearsafter surgery. Conclusion Patients with blood culture-negative IE should receive adequate dosage and duration of broad-spectrum antibiotics to control the infection rapidly, and aggressive surgical therapy to decrease in-hospital mortality and improve their quality of life and prognosis.
ObjectiveTo investigate and evaluate the safety and efficacy of Bentall operation in the reoperation of patients with small aortic root or annulus.MethodsBentall procedure was performed in 24 patients with small aortic root or annulus in our hospital from September 2014 to December 2019. There were 18 males and 6 females with a mean age of 31-68 (45.70±15.27) years. All patients had undergone a previous replacement of the aortic valve including 20 patients receiving valve replacement, 2 patients aortic root replacement with a valved conduit and 2 patients bioprothesis replacement.ResultsThere was no early death in hospital and one death during the 30-day postoperative period. Re-thoracotomy due to bleeding was necessary in only 2 patients and no bleeding was related to the proximal anastomosis of the conduit. One patient performed pacemaker implantation for heart block after the procedure. The mean sizes of implanted aortic valve prosthesis were 22.75±1.78 mm. A mean gradient across the aortic valve prostheses in the postoperative echocardiographic examination was 11.17±2.24 mm Hg.ConclusionBentall procedure is safe and allows a larger size of prosthesis implantation in patients with small aortic annulus or root after previous aortic valve or complete root replacement, resulting in good postoperative hemodynamic characteristics and short-term clinical results.
Objective To investigate and evaluate the safety and effectiveness of the Chimney technique in mitral valve reoperation. Methods The clinical data of mitral valve reoperation patients who underwent Chimney surgery in Wuhan Asia Heart Hospital from 2019 to 2021 were retrospectively analyzed. Results A total of 26 patients were collected, including 7 males and 19 females, aged 27-67 (53.46±11.18) years. All patients had previous mitral valve surgery, including 23 mitral valve replacements and 3 mitral valve repairs. All patients received Chimney technique using the ideal artificial sized mitral valve, and 1 patient died of neurological complications in hospital. The cardiopulmonary bypass time and the aortic cross-clamping time were 231.11±77.05 min and 148.50±52.70 min, respectively. The mean diameter of the implanted mitral valve prosthesis was 29.08±0.68 mm, which was statistically different from pre-replacement valve prosthesis size of 26.69±0.77 mm (P<0.001). The mean transvalvular pressure gradient of the prosthetic mitral valve measured on postoperative echocardiography was 14.77±5.34 mm Hg, which was statistically different from preoperative value of 20.92±9.83 mm Hg (P=0.005). Conclusion The Chimney technique is safe and effective for reoperation in patients with small mitral annuli, which can not only reduce the risk of reoperation, but also obtain larger prosthetic valve implants with good hemodynamic characteristics and clinical outcomes.
Objective To investigate and evaluate the safety and efficacy of the aortic-mitral annular enlargement technique (double annular enlargement) in patients with small-size valve prostheses after prior valve surgery. MethodsThe clinical data of patients who underwent double valve annular enlargement in Wuhan Asia Heart Hospital from April 2020 to April 2022 were retrospectively analyzed. Results A total of 30 patients were collected, including 2 males and 28 females aged 9-78 (52.71±3.53) years. All patients had previous heart valve surgery, including 1 patient receiving the third heart surgery. All patients were operated on successfully and there were no postoperative in-hospital deaths. There was no postoperative bleeding which needed a secondary open-chest hemostasis, and one patient underwent permanent pacemaker implantation due to postoperative sick sinus syndrome. The mean diameter of the implanted prosthetic aortic valve was 24.23±1.60 mm, which was significantly larger than that of the preoperative aortic valve (21.03±1.90 mm, P<0.001). The mean diameter of the implanted prosthetic mitral valve was 28.33±1.21 mm, which was significantly larger than that of the preoperative mitral valve (25.43±0.84 mm, P<0.001). The mean peak gradient difference across the prosthetic aortic valve on postoperative echocardiography was 18.17±6.44 mm Hg, which was significantly lower than that of the preoperative aortic valve (82.57±24.48 mm Hg, P<0.001). The mean peak gradient difference of the postoperative prosthetic mitral valve was 12.73±5.45 mm Hg, which was significantly lower than that of the preoperative mitral valve (19.43±8.97 mm Hg, P=0.003). Conclusion The double annular enlargement technique is safe and effective for reoperation in patients with a history of valve surgery with a small aortic root to obtain both a larger size prosthetic valve for a larger orifice area and stability of the mitral-aortic valve union, resulting in good postoperative hemodynamic characteristics and clinical outcomes.
Objective To summarize the application of double valve ring enlargement combined with mitral Chimney technique (Chimney Commando) in the secondary valve replacement and to analyze the efficacy in the near and medium term. Methods Patients who underwent the secondary aortic valve and mitral valve (double valve) replacement by Chimney Commando in Wuhan Asia Heart Hospital from 2019 to 2022 were included, and their clinical data were retrospectively collected to analyze the safety and feasibility of this procedure in secondary valve replacement of small aortic root patients. Results A total of 49 patients (44 females and 5 males) were included. The body surface area was 1.64±0.17 m2. The time from the first operation was 13.10±5.90 years. Except for 4 patients whose first operation was valvuloplasty, the remaining 45 patients were all patients after valve replacement, 41 patients of double valves replacement, including 39 patients with mechanical valve and 2 patients with biological valve. The majority of the aortic valves were St.Jude regent 19 mm or St.Jude regent 21 mm, accounting for 30.61% and 34.69%, respectively. The mitral valves were predominantly St.Jude 25 mm mechanical valves, making up 65.31%. All patients underwent Chimney Commando double valve ring enlargement, and the mean time of aortic occlusion was 154.00±45.40 min. The mean size of the aortic valve was 23.90±1.40 mm and that of the mitral valve was 28.20±1.20 mm, and the transvalvular pressure difference across the aortic valve was 20.16±5.76 mm Hg at 6 months postoperatively. There was one death during hospitalization due to multi-organ failure. The follow-up time ranged from 1 to 24 months with a median time of 8 months. Two patients were implanted with permanent pacemakers during the follow-up period and 1 patient died due to massive stroke and malignant arrhythmia. Conclusion Chimney Commando is safe and effective in patients with secondary double valve replacement, and the postoperative prosthetic valves have good hemodynamics, and can achieve good clinical results in the near and medium term.