west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "Surgical procedures,minimally invasive" 3 results
  • Comparison of Curative Effects and Complications between Endoscope-assisted Treatment and Scalp Coronal Incision for Zygomatic Complex Fractures

    ObjectiveTo compare the curative effects and complications between endoscope-assisted treatment and scalp coronal incision for zygomatic complex fractures. MethodFifty zygomatic complex fracture patients treated between January 2008 to May 2014 were randomly divided into trial group (n=30) treated through endoscope-assisted procedure and control group (n=20) treated through scalp coronal incision. In the trial group, functional reduction and fixation of the fractures under endoscope were performed, and the control group was treated with coronal incision and internal fixation of the fractures. After the operation, all the patients were evaluated on the effects and complications through physical examination and CT review. ResultsThe number of grade-Ⅰ, -Ⅱ and-Ⅲ curative effects were respectively 24 (80.0%), 5 (16.7%), and 1 (3.3%) in the trial group, while those numbers in the control group were respectively 16 (80.0%), 3 (15.0%), and 1 (5.0%). There was no significant difference in the curative effects between the two groups (P>0.05). There were no cases of complications in the trial group, but there were 4 cases (20.0%) of facial nerve injury, 5 cases (25.0%) of hair loss, 4 cases (20.0%) of temporal sag, and 5 cases (25.0%) of scalp hematoma in the control group. The complication rate in the control group was significantly higher than that in the trial group (P<0.05). ConclusionsWhile the curative effects between endoscope-assisted treatment and scalp coronal incision for zygomatic complex fractures are not significantly different, endoscope-assisted technology can reduce the complications of the operation, which is a minimally invasive surgery and can promote good aesthetic appearance.

    Release date: Export PDF Favorites Scan
  • Noncontact wide-angle viewing system aided scleral buckling surgery for rhegmatogenous retinal detachment

    ObjectiveTo create a new scleral buckling surgery using noncontact wide-angle viewing system and 23-gauge intraocular illumination for the treatment of rhegmatogenous retinal detachment (RRD), and to evaluate its safety and effectiveness. MethodsA scleral buckling surgery using noncontact wide-angle viewing system and 23-gauge intraocular illumination was performed in 6 eyes of 6 patients with RRD, including 2 males and 4 females. The mean age was 51 years old with a range from 23 to 66 years old. Proliferative vitreoretinopathy (PVR) were diagnosed of grade B in all 6 eyes. Duration of retinal detachments until surgery was 5.8 days with a range from 2 to 13 days. The mean preoperative intraocular pressure (IOP) was 12 mmHg with a range from 9 to 15 mmHg (1 mmHg=0.133 kPa). A 23-gauge optic fiber was used to provide an intraocular illumination. Fully examination of the ocular fundus and cryoretinopexy of retinal breaks was performed under a noncontact wide-angle viewing system. Subretinal fluid drainage through the sclerotomy and buckling procedure were performed under the operating microscope. Intravitreal injection of sterile air bubble was performed in 4 eyes. Antibiotic eye drops was applied in all eyes postoperatively, and all the eyes were followed up for at least 6 months. ResultsRetinal reattachment was achieved in all eyes, and the conjunctiva healed well. The best corrected visual acuity (BCVA) increased in all eyes. The mean postoperative IOP was 15 mmHg with a range from 12 to 19 mmHg. No complications were found intra and postoperatively. ConclusionsThis new scleral buckling surgery using noncontact wide-angle viewing system and 23-gauge intraocular illumination for RRD is safe and effective. Advantages such as higher successful rate, less complication, shorter operating time, and less discomfort of patients were showed comparing with the previous scleral buckling surgery using indirect ophthalmoscope.

    Release date: Export PDF Favorites Scan
  • Comparison of modified 23G with suturing incision and traditional 23G vitrectomy for silicone oil removal

    ObjectiveTo compare the safety and efficacy of a modified 23G with suturing incision and traditional 23G vitrectomy for silicone oil removal. MethodsA total of 177 patients (180 eyes) who underwent silicon oil removal (the average tamponade period was 4.5 months) were enrolled in this prospective study. The patients included 112 males (113) and 65 female (67). The mean age was (43.8±10.3) years. The corrected vision, indirect ophthalmoscopy, intraocular pressure, B-ultrasound and optical coherence tomography were measured for all patients. All patients had no complete retinal detachment. The patients were randomly divided into modified 23G with suturing incision group (group A, 88 eyes) and traditional 23G vitrectomy (group B, 92 eyes). The differences of sex (χ2=1.596), age, corrected vision (t=0.785), intraocular pressure (t=0.352), primary disease (χ2=1.982) and lens condition (χ2=2.605) were not significant (P>0.05). The operation time, intraocular pressure, silicon oil retention, choroidal detachment, retinal redetachment and endoophthalmitis were recorded at the end of the operation. ResultsThe difference of mean operation time was not significant between group A and B (t=1.950,P>0.05). The differences of mean visual acuity 1 day, 1 week and 3 months after operation were not significant between group A and B (t=0.873, 1.115, 0.141; P>0.05). There was difference of mean intraocular pressure at 1 day after operation (t=2.550,P<0.05), but not at 1 week and 3 months after operation (t=1.451,1.062; P>0.05) between group A and B. There were 25 eyes (28.4%) with intraocular hypotension, 8 eyes (9.1%) with choroidal detachment, 5 eyes (5.7%) with vitreous hemorrhage, 9 eyes (10.2%) with retinal redetachment, and 7 eyes (8.0%) with silicon oil retention in group A. There were 5 eyes (5.4%) with intraocular hypotension, 2 eyes (2.2%) with choroidal detachment, 2 eyes (2.2%) with vitreous hemorrhage, 8 eyes (8.7%) with retinal redetachment, and 1 eye (1.1%) with silicon oil retention in group B. The differences of incidence of intraocular hypotension, choroidal detachment and silicon oil retention were significant (P<0.05). No endoophthalmitis occurred. ConclusionThe safety of modified 23G with suturing incision is better than traditional 23G vitrectomy for silicone oil removal, with decreased incidence of intraocular hypotension, choroidal detachment and silicon oil retention.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content