find Keyword "TiRobot" 6 results
  • Preliminary application study of dual-robotic navigated minimally invasive treatment by TiRobot and Artis Zeego on pelvic fractures

    Objective To summarize the surgical learning curve and preliminary operative experience of dual-robotic navigated minimally invasive treatment on pelvic fractures by TiRobot and Artis Zeego. Methods Between July 2019 and February 2021, 90 patients with pelvic fractures were treated with dual-robotic navigated minimally invasive surgery by TiRobot and Artis Zeego. There were 64 males and 26 females, with an average age of 46.5 years (range, 13-78 years). Body mass index was 14.67-32.66 kg/m2 (mean, 23.61 kg/m2). Causes of injuries included traffic accident in 43 cases, falling from height in 37 cases, low-energy injuries such as flat falls in 10 cases. The interval between injury and surgery was 1-36 days (mean, 7.3 days). According to the location of the implanted screws, the patients were divided into sacroiliac screw group (n=33), acetabular screw group (acetabulum anterior/posterior column, n=24), composite screws group (sacroiliac and acetabulum anterior/posterior column, n=33). According to the screw implantation time and accuracy, the surgical learning curve was plotted, and the differences in the relevant indicators between learning stage and skilled stage were compared. Results All 90 patients successfully completed the operation, the intraoperative bleeding volume was 5-200 mL (median, 20 mL). There was no vascular or nerve injury. All incisions healed by first intention. The screw implantation time ranged from 7.5 to 33.0 minutes (mean, 18.92 minutes), and the screw implantation accuracy ranged from 1.1 to 1.8 mm (mean, 1.56 mm). According to the learning curve, the practice stage of 3 groups was reached after 7, 10, and 11 cases, respectively. With the accumulation of surgical experience, the screw implantation time had a significant downward trend. Compared with the learning stage, the screw implantation time on skilled stage in 3 groups significantly shortened (P<0.05), but the difference in the screw implantation accuracy was not significant (P>0.05). Conclusion TiRobot and Artis Zeego assisted pelvic fracture surgery is safe and efficient, which helps the surgeon to quickly master the pelvic channel screw surgery, and the operation time is significantly shortened on the premise of ensuring the implantation accuracy.

    Release date: Export PDF Favorites Scan
  • TiRobot-assisted surgery by O-arm navigation system for percutaneous minimally invasive treatment of posterior pelvic ring injury

    ObjectiveTo evaluate the effectiveness of TiRobot-assisted surgery by O-arm navigation system for percutaneous minimally invasive treatment of posterior pelvic ring injury. Methods The clinical data of 76 patients with posterior pelvic ring injury between January 2016 and June 2021 were retrospectively analyzed. Among them, 45 cases were treated with minimally invasive percutaneous sacroiliac screw fixation assisted by TiRobot and O-arm navigation system (study group), 31 cases were treated with minimally invasive percutaneous sacroiliac screw fixation under the guidance of C-arm X-ray machine (control group). There was no significant difference in gender, age, cause of injury, Tile classification, time from injury to operation between the two groups (P>0.05). The operation time, intraoperative blood loss, the times of nail track adjustment, and intraoperative fluoroscopy times were recorded. The quality of fracture reduction was evaluated by Matta score. At last follow-up, Majeed score was used to evaluate the recovery of pelvic function. ResultsA total of 72 screws were implanted in the study group, with a median of 1 (1, 2) screws per patient. In the control group, 47 screws were implanted, with a median of 1 (1, 2) screws per patient. There was no significant difference in the number of screws between the two groups (Z=−0.392, P=0.695). The operation time, intraoperative blood loss, times of nail track adjustment, and intraoperative fluoroscopy times in the study group were significantly less than those in the control group (P<0.05). All patients were followed up 6-24 months (mean, 14 months). No serious complications was found after operation and during follow-up. Matta score was used to evaluate the quality of fracture reduction at 1 week after operation, and there was no significant difference between the two groups (Z=−1.135, P=0.256). At last follow-up, there was no significant difference of Majeed score between the two groups (Z=−1.279, P=0.201). ConclusionTiRobot-assisted surgery by O-arm navigation system is a reliable surgical method for the treatment of posterior pelvic ring injury, which can reduce the operation time and fluoroscopy times when compared with the traditional operation under the guidance of C-arm X-ray machine. The safety, accuracy, and efficiency of the operation were improved.

    Release date: Export PDF Favorites Scan
  • TiRobot-assisted percutaneous sacroiliac cannulated screw fixation for posterior pelvic ring injury with sacral variations

    ObjectiveTo investigate the effectiveness of TiRobot-assisted percutaneous sacroiliac cannulated screw fixation in the treatment of posterior pelvic ring injuries with sacral variations, and to evaluate its feasibility and safety. Methods The clinical data of 7 patients with Tile type C pelvic fractures and sacral variations treated with TiRobot-assisted percutaneous sacroiliac cannulated screw fixation between January 2020 and June 2021 were retrospectively analyzed. There were 5 males and 2 females with an average age of 36 years (range, 17-56 years). The causes of injury were traffic accident in 4 cases and falling from height in 3 cases. According to Tile classification of pelvic fractures, there were 1 case of type C1.1, 1 case of type C1.2, and 5 cases of type C1.3; according to Denis classification of sacral fractures, there were 3 cases of zone Ⅰ and 4 cases of zone Ⅱ; sacral deformities included 3 cases of lumbar sacralization, 2 cases of sacral lumbarization, and 2 cases of accessory auricular surface of the sacrum. The time from injury to operation ranged from 2 to 7 days, with an average of 4.6 days. The implantation time of each screw, the fluoroscopy times of each guide pin, the quality of fracture reduction (according to Matta score), the excellent and good rate of screw position, the healing time of fracture, and the incidence of complications were recorded, and the effectiveness was evaluated by Majeed score. Results A total of 13 screws were implanted during the operation, the implantation time of each screw was 10-23 minutes, with an average of 18.2 minutes; the position of the guide pin was good, and no guide pin was adjusted, the fluoroscopy times of each guide pin were 3-7 times, with a median of 4 times. Postoperative imaging data at 3 days showed that the position of sacroiliac screw implantation was evaluated as excellent. No complication such as incision infection or vascular nerve injury occurred, and no adverse events related to robotic devices occurred. At 3 days after operation, according to Matta score, the quality of fracture reduction was excellent in 6 cases and good in 1 case, and the excellent and good rate was 100%. All the 7 patients were followed up 6-15 months, with an average of 12.4 months. Bone union was achieved in all patients, and the healing time ranged from 18 to 24 weeks, with an average of 21.2 weeks. Majeed score at last follow-up was 81-95, with an average of 91.5; 5 cases were excellent, 2 cases were good, and the excellent and good rate was 100%. ConclusionTiRobot-assisted percutaneous sacroiliac cannulated screw fixation for posterior pelvic ring injury with sacral variation is accurate, safe, minimally invasive, and intelligent, and the effectiveness is satisfactory.

    Release date: Export PDF Favorites Scan
  • Short-term effectiveness of TiRobot combined with O-arm navigation system in minimally invasive treatment of hindfoot fracture

    Objective To investigate the short-term effectiveness of TiRobot combined with O-arm navigation system in the minimally invasive treatment of hindfoot fracture. Methods Between March 2019 and March 2021, 25 patients with hindfoot fractures were admitted. There were 14 males and 11 females, with an average age of 51.7 years (range, 19-76 years). The causes of injuries included falling from height in 17 cases and traffic accident in 8 cases. The interval between injury and operation was 1-3 days (mean, 2.1 days). There were 16 cases of calcaneus fracture, 7 cases of talus fracture, and 2 cases of calcaneus and talus fractures. According to Sanders classification criteria, the calcaneus fractures were classified as type Ⅱ in 10 cases and type Ⅲ in 8 cases; according to the Hawkins classification criteria, the talus fractures were classified as type Ⅱ in 4 cases and type Ⅲ in 5 cases. Preoperative American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score was 48.1±9.1. During operation, the fractures were fixed with the percutaneous cannulated screws with the assistance of the TiRobot combined with the O-arm navigation system. The operation time, hospital stay, and the occurrence of related complications were recorded. X-ray films were reviewed to evaluate the fracture healing and the occurrence of talus osteonecrosis, and the width, length, height, Böhler’s angle, and Gissane’s angle of the calcaneus were measured; AOFAS ankle-hindfoot score was used to evaluated the foot function. Results The operation time ranged from 47 to 71 minutes (mean, 60.5 minutes). The length of hospital stay ranged from 2 to 5 days (mean, 3.4 days). All incisions healed by first intention. All patients were followed up 12-24 months (mean, 17.3 months). One patient demonstrated hypoesthesia on the lateral side of foot after operation and recovered after symptomatic treatment. All fractures healed confirmed by X-ray films and the healing time ranged from 10 to 16 weeks (mean, 11.8 weeks). No talus osteonecrosis occurred during follow-up. There were significant differences in the width, length, height, Böhler’s angle, and Gissane’s angle of the calcaneus between pre-operation and at last follow-up (P<0.05). At last follow-up, AOFAS ankle-hindfoot score was 91.2±5.0, the difference was significant when compared with preoperative score (t=22.169, P<0.001). The results were excellent in 16 cases and good in 9 cases, with an excellent and good rate of 100%. Conclusion TiRobot combined with O-arm navigation system for minimally invasive treatment of hindfoot fractures can obtain the satisfactory short-term effectiveness, with the advantages of less surgical trauma, precise fixation, and fewer complications.

    Release date: Export PDF Favorites Scan
  • Effectiveness of modified orthopedic robot-assisted percutaneous kyphoplasty in treatment of osteoporotic vertebral compression fracture

    ObjectiveTo evaluate the effectiveness of orthopedic robot with modified tracer fixation (short for modified orthopedic robot) assisted percutaneous kyphoplasty (PKP) in treatment of single-segment osteoporotic vertebral compression fracture (OVCF). Methods The clinical data of 155 patients with single-segment OVCF who were admitted between December 2017 and January 2021 and met the selection criteria was retrospectively analyzed. According to the operation methods, the patients were divided into robot group (87 cases, PKP assisted by modified orthopedic robot) and C-arm group (68 cases, PKP assisted by C-arm X-ray fluoroscopy). There was no significant difference in gender, age, body mass index, T value of bone mineral density, therapeutic segment, grade of vertebral compression fracture, and preoperative visual analogue scale (VAS) score, midline vertebral height, and Cobb angle between the two groups (P>0.05). The effectiveness evaluation indexes of the two groups were collected and compared. The clinical evaluation indexes included the establishment time of working channel, dose of intraoperative fluoroscopy, the amount of injected cement, VAS score before and after operation, and the occurrence of complications. The imaging evaluation indexes included the degree of puncture deviation, the degree of bone cement diffusion, the leakage of bone cement, the midline vertebral height and the Cobb angle before and after operation. Results The establishment time of working channel in robot group was significantly shorter than that in C-arm group, and the dose of intraoperative fluoroscopy was significantly larger than that in C-arm group (P<0.001). There was no significant difference in the amount of injected cement between the two groups (t=1.149, P=0.252). The patients in two groups were followed up 10-14 months (mean, 12 months). Except that the intraoperative VAS score of the robot group was significantly better than that of the C-arm group (P<0.05), there was no significant difference between the two groups at other time points (P>0.05). No severe complication such as infection, spinal cord or nerve injury, and pulmonary embolism occurred in the two groups. Five cases (5.7%) in robot group and 7 cases (10.2%) in C-arm group had adjacent segment fracture, and the difference in incidence of adjacent segment fracture between the two groups was not significant (χ2=1.105, P=0.293). Compared with C-arm group, the deviation of puncture and the diffusion of bone cement at 1 day after operation, the midline vertebral height and Cobb angle at 1 month after operation and last follow-up were significantly better in robot group (P<0.05). Eight cases (9.1%) in the robot group and 16 cases (23.5%) in the C-arm group had cement leakage, and the incidence of cement leakage in the robot group was significantly lower than that in the C-arm group (χ2=5.993, P=0.014). There was no intraspinal leakage in the two groups. ConclusionCompared with traditional PKP assisted by C-arm X-ray fluoroscopy, modified orthopedic robot-assisted PKP in the treatment of single-segment OVCF can significantly reduce intraoperative pain, shorten the establishment time of working channel, and improve the satisfaction of patients with operation. It has great advantages in reducing the deviation of puncture and improving the diffusion of bone cement.

    Release date: Export PDF Favorites Scan
  • Effectiveness of TiRobot-assisted and free-hand percutaneous kyphoplasty via pedicle of vertebra in treatment of osteoporotic vertebral compression fracture of thoracic vertebra

    Objective To compare the effectiveness of TiRobot-assisted and C-arm X-ray fluoroscopy assisted percutaneous kyphoplasty (PKP) via pedicle of vertebra in the treatment of osteoporotic vertebral compression fracture (OVCF) of thoracic vertebrae. Methods The clinical data of 85 patients with OVCF of thoracic vertebrae who were admitted between January 2020 and March 2023 and met the selection criteria was retrospectively analyzed including 40 patients (50 vertebrae) undergoing PKP assisted by TiRobot (group A) and 45 patients (50 vertebrae) undergoing PKP assisted by C-arm X-ray fluoroscopy (group B). There was no significant difference in the comparison of baseline data such as gender, age, body mass index, bone mineral density T-value, fracture segment, trauma history, and preoperative numerical rating scale (NRS) score, Oswestry disability index (ODI), and Cobb angle of injured vertebra between the two groups (P>0.05). The effectiveness evaluation indexes of the two groups, including the operation time, the volume of injected cement, the times of fluoroscopies, the length of hospital stay, and the occurrence of postoperative complications were collected and compared. Anteroposterior and lateral X-ray films and CT of the injured vertebra were reviewed at 1 day after operation to observe whether there was cement leakage and to evaluate the distribution of cement in the injured vertebra. Before and after operation, pain was assessed using the NRS score, dysfunction was assessed using the ODI, and vertebral height recovery was assessed by measuring the Cobb angle of the injured vertebrae by X-ray films. Results Both groups of patients successfully completed the operation, the operation time, the volume of injected cement, the times of fluoroscopies, and the length of hospital stay in group A were significantly less than those in group B (P<0.05). The patients in two groups were followed up 4-12 months (mean, 9.6 months). Bone cement leakage occurred in 5 vertebrae in group A and 15 vertebrae in group B after operation, all of which leaked to the intervertebral space and around the vertebral body, and the patients had no obvious clinical symptoms. The difference of bone cement leakage between the two groups was significant (P<0.05). No severe complication such as intraspinal leakage, infection, or vascular embolism was found in the two groups. At 1 day after operation, the distribution index of bone cement in group A was mostly grade Ⅴ, which was well dispersed; while in group B, it was mostly grade Ⅱ and grade Ⅴ; the difference of bone cement distribution index between the two groups was significant (P<0.05). The NRS score, ODI, and Cobb angle of injured vertebra in both groups were significantly improved at 1 day after operation when compared with preoperative ones (P<0.05). There was no significant difference in the difference of the above indexes between the two groups before and after operation (P>0.05). Conclusion TiRobot-assisted unilateral PKP in the treatment of OVCF of thoracic vertebrae is safe and effective, which can reduce the X-ray transmission times during operation, shorten the operation time, reduce the volume of bone cement injection, and thus decrease incidence of bone cement leakage.

    Release date: Export PDF Favorites Scan