west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "Time in therapeutic range" 2 results
  • Self-management of Anticoagulation Monitoring for Patients Following Mechanical Heart Valve Replacement: A non-randomized Controlled Trial

    Objective To discuss the application value in increasing the frequency of monitoring and ensuring the safety of anticoagulation therapy in patient self-monitoring (PST) and self-management (PSM) of portable coagulometer. Method This non-randomized prospective controlled study was conducted in 100 patients receiving oral warfarin anticoagulation therapy after heart valve replacement and met the inclusion criteria in our hospital between March 2013 and April 2014 year. All the patients were divided into three groups including an outpatient follow-up group(outpatient group), a self-monitoring group and a self-management group. Meanwhile, the patients in the outpatient group visited professional institutions, performed international normalized ratio (INR) testing with central lab and adjusted the dosage of orally administered warfarin by the doctors. And the other two groups performed INR testing with CoaguChek XS portable coagulometer by themselves, and the patients in the self-management group performed management by themselves. The follow-up time was 6 months. The dates of time in therapeutic range (TTR), fraction of time in therapeutic range (FTTR) and anticoagulation complications in the three groups were analyzed and compared. Results There was no significant difference in the INR results obtained from the follow-up time among the three groups (P=0.845) . TTR value of INR of the outpatient group, the self-monitoring group, and the self-management group was 45.9% (4368.0 days/9517.0 days), 61.2% (6057.0 days/9897.0 days), and 65.4% (2833.8 days/4333.0 days), respectively with a statistical difference among the three groups (P<0.001) . FTTR value of INR obtained from the outpatient group, the self-monitoring group, and the self-management group was 48.3% (99 times/205 times), 60.7% (164 times/270 times), and 64.9% (100 times/154 times) respectively. There was a statistical difference in the FTTR between the outpatient group and the self-monitoring group (P=0.007) , and also between the outpatient group and the self-monitoring group (P=0.002) . But there was no statistical difference between the self-monitoring group and the self-management group (P=0.392) . There were not any major bleeding and thrombosis complications in all study. And there was no statistical difference in the total complications, thrombosis, and bleeding complications rates between the outpatient group and the self-monitoring group, and also between the outpatient group and the self-management group (P>0.05) . Conclusions The patients receiving oral anticoagulation after heart valve replacement or their care providers were able to perform PST and PSM. The use of portable coagulometer for self-monitoring and self-management can increase the frequency of anticoagulation monitoring and achieve better INR target value control. PST and PSM could achieve higher quality of anticoagulation management and life and without increasing the risk of oral anticoagulation than the traditional monitoring method. The monitoring frequency of once a month is reasonable for the patients receiving oral anticoagulation more than half a year after heart valve replacement.

    Release date: Export PDF Favorites Scan
  • Initial Evaluation of Reasonableness of Target INR 1.60 to 2.20 and Warfarin Weekly Dosage Adjustment in Patients after Mechanical Heart Valve Replacement

    ObjectiveTo evaluate the reasonableness of anticoagulation management strategy in patients after mechanical heart valve replacement. MethodsAll patients were followed and registered continually at outpatient clinic from July 2011 to February 2013, with a minimum of 6 months after surgery. Targeted international normalized rate (INR) 1.60 to 2.20 and warfarin weekly dosage adjustment were used as the strategy of anticoagulation management. Except bleeding, thrombogenesis and thromboembolism, time in therapeutic range (TTR) and fraction of TTR (FTTR) were adopted to evaluate the quality of anticoagulation management. ResultsA total 1 442 patients and 6 461 INR values were included for data analysis. The patients had a mean age of 48.2±10.6 years (14-80 years) and the following up time were 6 to 180 months (39.2±37.4 months) after surgery. Of these patients, 1 043 (72.3%) was female and 399 (27.7%) was male. INR values varied from 0.90-8.39 (1.85±0.49) and required weekly doses of warfarin were 2.50-61.25 (20.89±6.93 mg). TTR of target INR and acceptable INR were 51.1% (156 640.5 days/306 415.0 days), 64.9% (198 856.0 days/306 415.0 days), respectively. FTTR of target INR and acceptable INR were 49.4% (3 193 times/6 461 times), 62.6% (4 047 times/6 461 times). There were 8 major bleeding events, 7 mild bleeding events, 2 thromboembolism events, and 2 thrombogenesis in the left atrium. ConclusionIt is reasonable to use target INR 1.60-2.20 and warfarin weekly dosage adjustment for patients after mechanical heart valve replacement.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content