west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "Vision/physiology" 2 results
  • Characteristics of electroretinograms in preterm infants

    Objective To investigate the degree of retinal developmen t in pret erm infants and compare the electroretinograms between preterm and fullterm in fants. Methods Flash electroretinogram (ERG) were obtained wit h contact lens el ectrodes in one eye from ten preterm infants (10 eyes) and twenty full-term inf a nts (20 eyes) in seven days after birth. The rod cell, cone cell, maximal combi nation, oscillatory potentials, and 30 Hz flicker responses were recorded. Results Compared with the full-term infants, the implicit time of rod cell respon s e (t=3.216,P=0.003) was longer and the amplitudes were lower (t=6.0 50,P=0.000) in the preterm infants; the difference of implicit time of maximal response was not significant (t=0.465,P=0.650; t=1.068,P=0.295), while th e amplitudes dec reased (t=6.584, P=0.000; t=6.649, P=0.000). The a- and b-wav e implicit time of cone response was not differed much between the two groups (t=0.077, P=0.939; t=0.935,P=0.358); the amplitudes was obvious lower in preterm group (t =3 .417,P=0.002;t=6.310,P=0.000); the difference of implicit t ime of 30 Hz flic ker betw een the two groups was not significant (t=3.745,P=0.001). The difference of b/a value of maximal combination response was not obvious between the two groups ( t=0.215, P=0.831). Conclusions The development of retinal function is slower in preterm infants than that in full-term ones.

    Release date:2016-09-02 05:46 Export PDF Favorites Scan
  • The effect of electrode positions on multifocal visual evoked potential

    Objective To compare the effect of electrode positions on multifocal visual evoked potential(mf-VEP). Methods Ten healthy individuals were tested with RETIscan multifocal VEP system 3.20, each individual was tested with four electrode positions: the active and reference electrode were placed 2.0 cm above and below the inion in Ch1;3.0 cm above and 4.5 cm below the inion in Ch2;2.0 cm on both right and left side of the inion in Ch3 and 4.0 cm on both right and left side of the inion in Ch4. The summed amplitudes of hemifield mf-VEP were analyzed and compared according to different electrode positions. Results The difference among summed amplitudes of the upper or lower hemifield mf-VEP recorded with Ch1、Ch2、Ch3 and Ch4 was statistically significant;and the difference between Ch2 and the other channels was statistically significant too. The difference among summed amplitudes of the horizontal sites whose amplitudes were small when recorded with Ch2 and summed amplitudes of the corresponding sites recorded with Ch3 and Ch4 were statistically significant;and the difference between Ch4 and the other channels was statistically significant too. Conclusions compared to Ch1、Ch3 and Ch4, Ch2 can make a better recording of mf-VEP. As for some sites, especially those along horizontal line, horizontal electrodes could improve the amplitudes of mf-VEP recorded with vertical electrodes,and Ch4 could do better to improve the mf-VEP recorded with Ch2 than Ch3. (Chin J Ocul Fundus Dis,2004,20:346-348)

    Release date:2016-09-02 05:58 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content