west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "WAN Lun" 9 results
  • SURGICAL TREATMENT OF LUMBAR SPONDYLOLISTHESIS WITH CAGES AND TRANSPEDICAL SCREWS

    Objective To observe the effect of threaded titanium cage and transpedical screw for the treatment of lumbar spondylolisthesis. Methods Eighteen patients with lumbar spondylolisthesis were adopted in this study. Among them, there were 8 males and 10 females, aged from 43 to 62 years old .Roentgenogramshowed that there were 6 cases of Ⅰ° spondylolisthesis, 11 cases of Ⅱ° and 1 case of Ⅲ°. All patients were treated with cages for intervertebral fusion after total laminectomy and pedicle screws for the reduction. Results The cases were followed up from 6 to 12 months with an average of 11 months. The clinical results were excellent in 13 cases and good in 5 cases. All patients achieved successful fusion and bony union . There were no pedicle screw loosening or broken or peripheral nerve dysfunction in this series. Conclusion This method has been proved to be an effective and reliable procedure for treatment of lumbar spondylolithesis. It produces a high fusion rate and clinical success.

    Release date: Export PDF Favorites Scan
  • Effect of prophylactic C4, 5 foraminal dilatation in posterior cervical open-door surgery on postoperative C5 nerve root palsy syndrome

    ObjectiveTo investigate the effect of prophylactic C4, 5 foraminal dilatation in posterior cervical open-door surgery on postoperative C5 nerve root palsy syndrome.MethodsThe clinical data of patients with cervical spondylotic myelopathy (cervical spinal cord compression segments were more than 3) who met the selection criteria between March 2016 and March 2019 were retrospectively analyzed. Among them, 40 patients underwent prophylactic C4, 5 foraminal dilatation in posterior cervical open-door surgery (observation group) and 40 patients underwent simple posterior cervical open-door surgery (control group). There was no significant difference between the two groups (P>0.05) in gender, age, disease duration, Nurick grade of spinal cord symptoms, and preoperative diameter of C4, 5 intervertebral foramen, Japanese Orthopaedic Association (JOA) score, and visual analogue scale (VAS) score. The occurrence of C5 nerve root paralysis syndrome was recorded and compared between the two groups, including incidence, paralysis time, recovery time, and spinal cord drift. VAS and JOA scores were used to evaluate the improvement of pain and function before operation and at 12 months after operation.ResultsThe incisions of the two groups healed by first intention, and there was no early postoperative complications such as cerebrospinal fluid leakage. Patients of both groups were followed up 12-23 months, with an average of 17.97 months. C5 nerve root paralysis syndrome occurred in 8 cases in the observation group (3 cases on the right and 5 cases on the left) and 2 cases in the control group (both on the right). There was significant difference of the incidence (20% vs. 5%) between the two groups (χ2=4.114, P=0.043). Except for 1 case in the observation group who developed C5 nerve root palsy syndrome at 5 days after operation, the rest patients all developed at 1 day after operation; the recovery time of the observation group and the control group were (3.87±2.85) months and (2.50±0.70) months respectively, showing no significant difference between the two groups (t=–0.649, P=0.104). At 12 months after operation, the JOA score and VAS score of cervical spine in the two groups significantly improved when compared with those before operation (P<0.05); there was no significant difference in the difference of the cervical spine JOA score and VAS score between at 12 months after operation and before operation and the degree of spinal cord drift between the two groups (P>0.05).ConclusionProphylactic C4, 5 foraminal dilatation can not effectively prevent and reduce the occurrence of postoperative C5 root palsy, on the contrary, it may increase its incidence, so the clinical application of this procedure requires caution.

    Release date: Export PDF Favorites Scan
  • Effectiveness of modified orthopedic robot-assisted percutaneous kyphoplasty in treatment of osteoporotic vertebral compression fracture

    ObjectiveTo evaluate the effectiveness of orthopedic robot with modified tracer fixation (short for modified orthopedic robot) assisted percutaneous kyphoplasty (PKP) in treatment of single-segment osteoporotic vertebral compression fracture (OVCF). Methods The clinical data of 155 patients with single-segment OVCF who were admitted between December 2017 and January 2021 and met the selection criteria was retrospectively analyzed. According to the operation methods, the patients were divided into robot group (87 cases, PKP assisted by modified orthopedic robot) and C-arm group (68 cases, PKP assisted by C-arm X-ray fluoroscopy). There was no significant difference in gender, age, body mass index, T value of bone mineral density, therapeutic segment, grade of vertebral compression fracture, and preoperative visual analogue scale (VAS) score, midline vertebral height, and Cobb angle between the two groups (P>0.05). The effectiveness evaluation indexes of the two groups were collected and compared. The clinical evaluation indexes included the establishment time of working channel, dose of intraoperative fluoroscopy, the amount of injected cement, VAS score before and after operation, and the occurrence of complications. The imaging evaluation indexes included the degree of puncture deviation, the degree of bone cement diffusion, the leakage of bone cement, the midline vertebral height and the Cobb angle before and after operation. Results The establishment time of working channel in robot group was significantly shorter than that in C-arm group, and the dose of intraoperative fluoroscopy was significantly larger than that in C-arm group (P<0.001). There was no significant difference in the amount of injected cement between the two groups (t=1.149, P=0.252). The patients in two groups were followed up 10-14 months (mean, 12 months). Except that the intraoperative VAS score of the robot group was significantly better than that of the C-arm group (P<0.05), there was no significant difference between the two groups at other time points (P>0.05). No severe complication such as infection, spinal cord or nerve injury, and pulmonary embolism occurred in the two groups. Five cases (5.7%) in robot group and 7 cases (10.2%) in C-arm group had adjacent segment fracture, and the difference in incidence of adjacent segment fracture between the two groups was not significant (χ2=1.105, P=0.293). Compared with C-arm group, the deviation of puncture and the diffusion of bone cement at 1 day after operation, the midline vertebral height and Cobb angle at 1 month after operation and last follow-up were significantly better in robot group (P<0.05). Eight cases (9.1%) in the robot group and 16 cases (23.5%) in the C-arm group had cement leakage, and the incidence of cement leakage in the robot group was significantly lower than that in the C-arm group (χ2=5.993, P=0.014). There was no intraspinal leakage in the two groups. ConclusionCompared with traditional PKP assisted by C-arm X-ray fluoroscopy, modified orthopedic robot-assisted PKP in the treatment of single-segment OVCF can significantly reduce intraoperative pain, shorten the establishment time of working channel, and improve the satisfaction of patients with operation. It has great advantages in reducing the deviation of puncture and improving the diffusion of bone cement.

    Release date: Export PDF Favorites Scan
  • PREPARATION OF BASIC FIBROBLAST GROWTH FACTOR CHITOSAN MICROSPHERE AND ITS PROPERTIES

    Objective To study the release properties of basic fibroblast growth factor (bFGF) chitosan microspheres prepared by cross-linking-emulsion method using chitosan as a carrier material so as to lay a foundation for further study. Methods Using 0.6% sodium tripolyphosphate solution as a crosslinking agent and 1.5% solution of chitosan as a carrier material, bFGF chitosan microspheres were prepared by cross-linking-emulsion method. Laser particle size analyzer and Zeta electric potential analyzer were used to measure the particle diameter distribution, scanning electronic microscope to observe the morphology, and ELISA to determine the drug loading, the encapsulation rate, and the drug release properties. Results The particle size of bFGF chitosan microspheres ranged 20.312-24.152 μm. The microspheres were round with a smooth surface and uniform distribution, and it had no apparent porosity. The drug loading and encapsulation rate of microspheres were (7.57 ± 0.34) mg/g and 95.14% ± 1.58%, respectively. The bFGF chitosan microspheres could continuously release bFGF for 24 days; the bFGF level increased gradually with time and reached (820.45 ± 21.34) ng/mL at 24 days; and the microspheres had a burst effect, and the burst rate was 18.08%, and the accumulative release rate of the microspheres reached 82.05% during 24 days. Conclusion It is easy-to-operate to prepare the bFGF chitosan microspheres with the cross-linking-emulsion method. The bFGF chitosan microspheres have smooth surface, uniform distribution, and no apparent porosity.

    Release date:2016-08-31 04:24 Export PDF Favorites Scan
  • Short-term effectiveness comparison between robotic-guided percutaneous minimally invasive pedicle screw internal fixation and traditional open internal fixation in treatment of thoracolumbar fractures

    ObjectiveTo compare short-term effectiveness between robot-guided percutaneous minimally invasive pedicle screw internal fixation and traditional open internal fixation in the treatment of thoracolumbar fractures.MethodsThe clinical data of 52 cases of thoracolumbar fracture without neurological injury symptoms admitted between January 2018 and May 2018 were retrospectively analyzed. According to the different surgical methods, they were divided into minimally invasive group (24 cases, treated with robot-assisted percutaneous minimally invasive pedicle screw internal fixation) and open group (28 cases, treated with traditional open internal fixation). There was no significant difference between the two groups in the general data such as gender, age, cause of injury, fracture segment, thoracolumbar injury classification and severity score (TLICS), preoperative back pain visual analogue scale (VAS) score, Oswestry disability index (ODI) score, fixed segment height, and fixed segment kyphosis Cobb angle (P>0.05). The operation time, intraoperative blood loss, and hospitalization time of the two groups were recorded and compared; as well as the VAS score, ODI score, fixed segment height, and fixed segment kyphosis Cobb angle of the two groups before operation and at 3 days, 1 month, 6 months, and 10 months after operation. CT scan was reexamined at 1-3 days after operation, and the pedicle screw insertion accuracy rate was determined and calculated according to Gertzbein-Robbins classification standard.ResultsThe operation time of the minimally invasive group was significantly longer than that of the open group, but the intraoperative blood loss and hospitalization time were significantly shorter than those of the open group (P<0.05). There were 132 pedicle screws and 158 pedicle screws implanted in the minimally invasive group and the open group respectively. According to the Gertzbein-Robbins classification standard, the accuracy of pedicle screws was 97.7% (129/132) and 96.8% (153/158), respectively, showing no significant difference between the two groups (χ2=0.505, P=0.777). The patients in both groups were followed up 10 months, and there was no rejection or internal fixation fracture. In the minimally invasive group, the internal fixator was removed at 10 months after operation, but not in the open group. The VAS score, ODI score, fixed segment heigh, and fixed segment kyphotic Cobb angle of the two groups were improved in different degrees when compared with preoperative ones (P<0.05). Except that the VAS score and ODI score of the minimally invasive group were significantly better than those of the open group at 3 days after operation (P<0.05), there was no significant difference between the two groups at other time points (P>0.05).ConclusionRobot-assisted percutaneous minimally invasive pedicle screw internal fixation for thoracolumbar fractures has significant advantages in intraoperative blood loss, hospitalization time, and early postoperative effectiveness and other aspects, and the effect of fracture reduction is good.

    Release date:2020-02-18 09:10 Export PDF Favorites Scan
  • Robot-guided percutaneous kyphoplasty in treatment of multi-segmental osteoporotic vertebral compression fracture

    ObjectiveTo evaluate the safety and effectiveness of robot-guided percutaneous kyphoplasty (PKP) in treatment of multi-segmental thoracolumbar osteoporotic vertebral compression fracture (OVCF).MethodsA clinical data of 63 cases with multi-segmental thoracolumbar OVCF without neurologic deficit treated with PKP between October 2017 and February 2019 were analyzed retrospectively. The patients were divided into robot-guided group (33 cases) and traditional fluoroscopy group (30 cases). There was no significant difference in gender, age, fracture segment, bone mineral density, and preoperative visual analogue scale (VAS) score, midline vertebral height, and Cobb angle between the two groups (P>0.05). The time to establish the tunnel, the times of fluoroscopy, the dose of fluoroscopy, the deviation of puncture, the distribution of bone cement, the leakage of bone cement, the puncture angle, and the postoperative VAS score, midline vertebral height, and Cobb angle were recorded and compared.ResultsThe patients in two groups were followed up 11-13 months (mean, 12 months). Compared with traditional fluoroscopy group, the time to establish the tunnel, the times and dose of fluoroscopy in robot-guided group were significantly lower, the deviation of puncture was slighter, the distribution of bone cement was better, and the puncture angle was larger, the differences between the two groups were significant (P<0.05). There were 8 segments (9.3%, 8/86) of bone leakage in robot-guided group and 17 segments (22.6%, 17/75) in traditional fluoroscopy group, the difference between the two groups was significant (χ2=5.455, P=0.020). There was no significant difference in VAS score, the midline vertebral height, and Cobb angle between the two groups at 2 days after operation and last follow-up (P>0.05).ConclusionRobot-guided PKP in treatment of multi-segmental thoracolumbar OVCF can shorten the operation time, improve the accuracy of puncture, reduce the times and dose of fluoroscopy, reduce the leakage of bone cement, and achieve better cement distribution.

    Release date:2020-09-28 02:45 Export PDF Favorites Scan
  • A comparative study of robot-assisted and freehand pedicle screw placement in upper thoracic surgery

    ObjectiveTo compare the safety and accuracy of pedicle screw placement assisted by robot system with freehand pedicle screw placement in upper thoracic surgery.MethodsBetween December 2017 and December 2019, 39 cases with upper thoracic pedicle screw internal fixation were included in the study, including 19 cases in robot group (group A, robot assisted pedicle screw placement) and 20 cases in freehand group (group B, freehand pedicle screw placement). There were 104 screws implanted in group A and 108 screws in group B. There was no significant difference in age, gender composition, body mass index, disease type, number of screws implanted, and segmental distribution between the two groups (P>0.05). The operation time, intraoperative blood loss, and postoperative drainage were recorded and compared between the two groups. CT scan was performed in all patients at 2 days after operation to evaluate the screw accuracy based on the Gertzbein-Robbins grading standard.ResultsThe operation time of group A was significantly longer than that in group B (t=2.759, P=0.009). There was no significant difference in intraoperative blood loss and postoperative drainage between the two groups (t=−0.796, P=0.431; t=−0.814, P=0.421). At 2 days after operation, according to Gertzbein-Robbins grading standard, the accuracy of pedicle screw implantation in group A were grade A in 94 screws, grade B in 9 screws, and grade C in 1 screw; and in group B were grade A in 72 screws, grade B in 26 screws, grade C in 9 screws, and grade D in 1 screw; the difference between the two groups was significant (Z=4.257, P=0.000). The accuracy rate of group A was 99.04%, and that of group B was 90.74%, showing significant difference (χ2=7.415, P=0.006).ConclusionCompared with traditional freehand pedicle screw placement, robot-assisted pedicle screw placement significantly improves the accuracy and safety of screw placement without increasing the bleeding and postoperative drainage.

    Release date:2021-01-07 04:59 Export PDF Favorites Scan
  • The safety of TiRobot-guided percutaneous transpedicular screw implantation

    ObjectiveTo evaluate the safety of TiRobot-guided percutaneous transpedicular screw implantation.MethodsThe medical records of 158 patients with thoracolumbar fractures and lumbar degenerative diseases who underwent percutaneous transpedicular screw implantation were retrospectively analyzed between January 2018 and December 2020. The patients were divided into trial group (TiRobot-guided screw implantation, 86 cases) and control group (fluoroscopy-guided screw implantation, 72 cases). There was no significant difference in gender, age, pathology, lesion segment, and the average number of screw implantation per case (P>0.05). The operation time, fluoroscopic dose, fluoroscopic time, and fluoroscopic frequency were compared between the two groups. One day postoperatively, the convergence angle was measured and the penetration of the pedicle cortex was evaluated according to Gertzbein-Robbins classification standard.ResultsThe operation time, fluoroscopic dose, fluoroscopic time, and fluoroscopic frequency of the trial group were significantly lesser than those of control group (P<0.05).One day postoperatively, the convergence angle of trial group was (21.10±4.08)°, which was significantly larger than control group (19.17±3.48)° (t=6.810, P=0.000). According to the Gertzbein-Robbins classification standard, 446 pedicle screws were implanted in trial group, trajectories were grade A in 377 screws, grade B in 46 screws, grade C in 23 screws, and the accuracy of screw implantation was 94.8%; 380 pedicle screws were implanted in control group, trajectories were grade A in 283 screws, grade B in 45 screws, grade C in 44 screws, grade D in 6 screws, grade E in 2 screws, and the accuracy of screw implantation was 86.3%. There was significant difference in the accuracy of screw implantation between the two groups (χ2=25.950, P=0.000). ConclusionCompared with traditional percutaneous transpedicular screw implantation, TiRobot-guided percutaneous transpedicular screw implantation can improve the accuracy of screw implantation, reduce radiation exposure, and improve surgical safety, which has a good application prospect.

    Release date:2021-06-30 04:43 Export PDF Favorites Scan
  • Effectiveness of robot-guided percutaneous fixation and decompression via small incision for advanced thoracolumbar metastases

    ObjectiveTo evaluate the effectiveness of robot-guided percutaneous fixation and decompression via small incision in treatment of advanced thoracolumbar metastases. Methods A clinical data of 57 patients with advanced thoracolumbar metastases admitted between June 2017 and January 2021 and met the selection criteria was retrospectively analyzed. Among them, 26 cases were treated with robot-guided percutaneous fixation and decompression via small incision (robot-guided group) and 31 cases with traditional open surgery (traditional group). There was no significant difference in gender, age, body mass index, lesion segment, primary tumor site, and preoperative Tokuhashi score, Tomita score, Spinal Instability Neoplastic Score (SINS), visual analogue scale (VAS) score, Oswestry disability index (ODI), Karnofsky score, and Frankel grading between groups (P>0.05). The operation time, hospital stays, hospital expenses, intraoperative blood loss, postoperative drainage volume, duration of intensive care unit (ICU) stay, blood transfusion, complications, and survival time were compared. The pedicle screw placement accuracy was evaluated according to the Gertzbein-Robbins grading by CT within 4 days after operation. The pain, function, and quality of life were evaluated by VAS score, ODI, Karnofsky score, and Frankel grading. Results During operation, 257 and 316 screws were implanted in the robot-guided group and the traditional group, respectively; and there was no significant difference in pedicle screw placement accuracy between groups (P>0.05). Compared with the traditional group, the operation time, hospital stays, duration of ICU stay were significantly shorter, and intraoperative blood loss and postoperative drainage volume were significantly lesser in the robot-guided group (P<0.05). There was no significant difference in hospital expenses, blood transfusion rate, and complications between groups (P>0.05). All patients were followed up 8-32 months (mean, 14 months). There was no significant difference in VAS scores between groups at 7 days after operation (P>0.05), but the robot-guided group was superior to the traditional group at 1 and 3 months after operation (P<0.05). The postoperative ODI change was significantly better in the robot-guided group than in the traditional group (P<0.05), and there was no significant difference in the postoperative Karnofsky score change and Frankel grading change when compared to the traditional group (P>0.05). Median overall survival time was 13 months [95%CI (10.858, 15.142) months] in the robot-guided group and 15 months [95%CI (13.349, 16.651) months] in the traditional group, with no significant difference between groups (χ2=0.561, P=0.454) . Conclusion Compared with traditional open surgery, the robot-guided percutaneous fixation and decompression via small incision can reduce operation time, hospital stays, intraoperative blood loss, blood transfusion, and complications in treatment of advanced thoracolumbar metastases.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content