ObjectiveTo analyze the early- and middle-term prognosis of various surgical methods in children with congenital aortic valve diseases, to provide reference for surgical methods in children with aortic valve stenosis or regurgitation.MethodsThe clinical data of 85 children with various aortic valve diseases treated in the Children’s Hospital of Fudan University from January 2005 to December 2018 were retrospectively analyzed. There were 64 males and 21 females, with an average age of 45 months ranging from 5 days to 15 years. Among them 18 patients underwent balloon aortic valvuloplasty (BAV), 8 surgical aortic valvotomy (SAV), 27 aortic valve autogenous pericardium repair, 16 mechanical arterial valve replacement and 16 Ross operation. They were followed up for 6.25±2.76 years. The re-intervention and survival status after different operations were analyzed.ResultsThere were 3 deaths and 17 reoperations in 85 children. The 5-year survival rate of the patients with SAV, BAV, aortic valve autogenous pericardium repair, mechanical arterial valve replacement and Ross operation was 87.4%, 88.9%, 100.0%, 100.0% and 100.0%, respectively; there was no statistical difference in the early and middle-term survival rates among various operations (P>0.05). The 5-year free from re-intervention rate of the patients with SAV, BAV, aortic valve autogenous pericardium repair, mechanical arterial valve replacement and Ross operation was 44.4%, 18.4%, 100.0%, 66.9% and 80.5%, respectively; there was a statistical difference in the early and middle-term re-intervention rate among various operations (P<0.05).ConclusionThe operation of congenital aortic stenosis or regurgitation needs to be performed according to the pathological changes of the valvular tissues. For children with severe lesions, SAV is recommended for the first intervention. For congenital aortic stenosis, SAV and BAV are both palliative operations which need further evaluation and re-intervention. Ross operation and mechanical arterial valve replacement have low re-intervention rate, and the middle- and long-term follow-up shows that the effect is accurate. Aortic valve autogenous pericardium repair is expected to become a method to delay or replace Ross operation and valve replacement.
Objective To discuss the relationship between calf muscle pump function and chronic venous insufficiency(CVI).Methods This summarized paper was made on literature review. Results Calf muscle pump function was studied by air plethysmography,straingauge plethysmography,intramuscular pressure,calf muscle pump efficiency,foot mercury straingauge plethysmography,isotope plethysmography,and digitized photo plethysmography.The calf muscle pump function of patients with CVI decreased apparently and can be markedly improved after proper treatment. Conclusion The relationship between calf muscle pump function and CVI is apparent.
Objective To analyze the outcomes and complications after total knee replacement(TKR) with posterior stabilized prosthesis(PS) and to investigate the influencing factors relating to outcomes. Methods From January 1998 to August2004, 60 cases (74 knees) of osteoarthritis underwent TKR with PS. The outcomeswere evaluated according to the HSS(hospital for special surgery) scoring. The difference in outcomes between patients with post-operative complications and without complications were compared. Pearson correlation was used to analyze post-operative outcomes and the pre-operative factors relating to patients. Results All 74 knees werefollowed up 42.5months(24 to 94 months). The scores for HSS, pain, function, ROM muscle strength, flexion deformity and stability of knees after operation were 84.2±14.2, 25.7±6.9, 17.9±4.3,13.1±2.0,9.2±0.8,8.1±0.4 and 9.3±0.1 respectively. They were improved to some extents, especially pain alleviation was remarkable. The excellent and good rate for outcome assessment was 90.5%. Among 74 knees, 10 cases suffered from postoperative complications, including 1 case of common peroneal nerve paralysis, two cases of wound faulty union, one case of wound infection, one case of joint infection, one case of stiff knee, two cases of deep vein thrombosis and 2 cases of patellofemoral joint complications. The excellent and good rate of outcome in patients with complications(60%) was much lower than that in patients without complication(95.3%),and there was significant difference betweenthem (P<0.05). Analysis for correlation showed that postoperative HSS score was positively correlative with the postoperative HSS score, pain and function score of knees. The correlation value was 0.523,0.431 and 0.418 respectively(Plt;0.01). Whereas, postoperative HSS score was not correlative with ROM, muscle strength, flexion deformity, stability of knee, age, weight andbody mass index(P>0.05). Conclusion TKR with PS is an effective method for severe osteoarthritis. The outcomes after TKR have a positive correlation with the HSS score, pain and function score of knees before surgery. Complicationsassociating with surgery have a negative influence on outcomes.
Lower extremity movement is a complex and large range of limb movement. Arterial stents implanted in lower extremity are prone to complex mechanical deformation, so the stent is required to have high comprehensive mechanical properties. In order to evaluate the mechanical property of different stents, in this paper, finite element method was used to simulate and compare the mechanical properties of six nitinol stents (Absolute Pro, Complete SE, Lifestent, Protégé EverFlex, Pulsar-35 and New) under different deformation modes, such as radial compression, axial compression/tension, bending and torsion, and the radial support performance of the stents was verified by experiments. The results showed that the comprehensive performance of New stent was better than other stents. Among which the radial support performance was higher than Absolute Pro and Pulsar-35 stent, the axial support performance was better than Complete SE, Lifestent and Protégé EverFlex stent, the flexibility was superior to Protégé Everflex stent, and the torsion performance was better than Complete SE, Lifestent and Protégé Everflex stent. The TTR2 type radial support force tester was used to test the radial support performance of 6 types, and the finite element analysis results were verified. The mechanical properties of the stent are closely related to the structural size. The result provides a reference for choosing a suitable stent according to the needs of the diseased location in clinical applications.
Surgery is an important method for the treatment of malignant tumors. Sevoflurane is one of the most common general anesthetics, which can directly or indirectly affect the biological behavior of cells and the immune function of tumor patients, thereby affecting the recurrence and metastasis of tumor patients after surgery. From the aspects of microRNA, matrix metalloproteinase, phosphatidylinositol-3-kinase/Akt signaling pathway and hypoxia-inducible factor-1α, this article summarizes the molecular mechanisms of sevoflurane affecting the biological behavior of tumor cells, and clarifies the regulation mechanism of sevoflurane on the immune function of tumor patients. It is expected to provide a theoretical basis for precise anesthesia for tumor patients, and to provide medication basis for reducing postoperative recurrence and metastasis of tumor patients.
Objective To compare the application effects of three psychometric instruments including SF-36, FLIC and QOL-LC in measuring the quality of life of patients with liver cancer. Methods A total of 105 in-patients with liver cancer selected from 2010 to 2011 were included. The quality of life was measured by FLIC, SF-36 and QOL-LC, respectively, and the reliability, validity and responsiveness were calculated and analyzed. Results The reliability and validity of QOL-LC were better than those of SF-36 and FLIC. Both QOL-LC and FLIC showed significant differences in responsiveness based on the changes of physical function and overall quality of life (QOL-LC: t=5.08, P=0.000, t=3.16, P=0.002; FLIC: t=4.02, P=0.000, t=2.21, P=0.030). Except for general health and mental health, the other domains of SF-36 showed significant differences in changes after treatment (physical function: t=5.94, P=0.000; physical role: t=3.07, P=0.003; body pain: t=3.21, P=0.002; vitality: t=3.22, P=0.002; social role: t=2.60, P=0.012; emotional role: t=3.28, P=0.002). Conclusion QOL-LC is a specific scale for liver cancer, and it should be used preferentially. SF-36 and FLIC can measure the general state of quality of life and can be used in patients with liver cancer when specific scale is not available.
Objective To investigate the effect of angiostatin gene combined with somastatin on inhibiting proliferation of human pancreatic cancer cell BXPC-3 and endothelial cell of vascular ECV-304 and on inducing their apoptosis in vitro. Methods The pcDNA3/angio was transfected BXPC-3 by liposome-mediated gene transfer method. RT-PCR and Western blot were used to detect the expression of angiostatin gene. In vitro, MTT and flow cytometry (FCM) were used to detect whether angiostatin gene combined with somastatin could effect the growth inhibition of BXPC-3 and ECV-304 cells. Results Angiostatin was expressed and secreted by transfected BXPC-3. The growth of BXPC-3 was inhibited by certain concentration of somatostatin (≥10 μg/ml, P<0.01), which was dependent on the dose of somatostatin in a concentration extent; Simultaneity apoptosis was induced (P<0.01). But the growth of ECV-304 was not inhibited with somatostation (Pgt;0.05). Angiostatin could inhibit the growth of ECV-304 and induced apoptosis (P<0.01), but it had no effect on the growth of BXPC-3 (Pgt;0.05). Angiostation gene combined with somatostation could inhibit the growth both of BXPC-3 and ECV-304 (P<0.01), and induce apoptosis of them (P<0.01); but the effect couldn’t be additived. Conclusions ①Somatostatin directly inhibits the proliferation of human pancreatic cancer cells and induces apoptosis, but it doesn’t directly inhibit angiogenesiso of human pancreatic cancer. ②Angiostatin specially inhibits the proliferation of endothelial cell of vascular and induces apoptosis. Angiostatin could inhibit angiogenesis of human pancreatic cancer to induce necrosis of cancer cell.
Objective To summarize the molecular biological research progress of non-coding RNAs modulating osteoarthritis (OA), and provide a reference basis for biological study and clinical treatment of OA. Methods Recent domestic and foreign related literature about the regulation of OA pathological process by non-coding RNAs was widely reviewed. Results Non-coding RNAs can be divided into three types based on the length of RNA. A lot of non-coding RNAs participating in OA pathological process are screened out by high throughput sequencing technology and microarray technology, and it is verified that these non-coding RNAs involve in the regulation of OA by RT-PCR. The mechanism of OA mediated target is clarified by knocking-down and overexpressing of the most prominent expressed non-coding RNAs in OA. There are the complicated gene expressed network topology in non-coding RNAs, and between non-coding RNAs and coding RNAs. It provides a basis for clearing the effect of gene structure and function, and finding the definite therapeutic target of OA. Conclusion There is preliminary study on molecular biological mechanism of non-coding RNAs mediating OA, but the key structure or sequence of non-coding RNAs, formation and interaction of effecting composite structure about mediating OA are unknown, and it needs further study.
Motor imagery (MI), motion intention of the specific body without actual movements, has attracted wide attention in fields as neuroscience. Classification algorithms for motor imagery electroencephalogram (MI-EEG) signals are able to distinguish different MI tasks based on the physiological information contained by the EEG signals, especially the features extracted from them. In recent years, there have been some new advances in classification algorithms for MI-EEG signals in terms of classifiers versus machine learning strategies. In terms of classifiers, traditional machine learning classifiers have been improved by some researchers, deep learning and Riemannian geometry classifiers have been widely applied as well. In terms of machine learning strategies, ensemble learning, adaptive learning, and transfer learning strategies have been utilized to improve classification accuracies or reach other targets. This paper reviewed the progress of classification algorithms for MI-EEG signals, summarized and evaluated the existing classifiers and machine learning strategies, to provide new ideas for developing classification algorithms with higher performance.
ObjectiveTo explore the effectiveness of open reduction and internal fixation for bipolar fracture-dislocation of the forearm.MethodsBetween June 2014 and March 2019, 14 patients with bipolar fracture-dislocation of the forearm were treated. There were 9 males and 5 females, aged from 19 to 52 years (mean, 34.9 years). There were 8 cases of falling injuries, 4 cases of traffic accident injuries, 1 case of sports injury, and 1 case of machine strangulation injury. The time from injury to admission was 2-48 hours, with an average of 16.6 hours. All patients were closed injuries. All patients were treated with open reduction and internal fixation; the upper radioulnar joints were treated with circumferential ligament repair or lateral collateral ligament repair according to the joint stability. And the patients with lower radioulnar joint instability were also treated with the TightRope plate with loop fixation. After 3 weeks of plaster fixation, the patients started functional exercises. The fracture healing time, stability and range of motion of wrist and elbow joints, and forearm rotation function were recorded. The effectiveness was evaluated by Anderson’s forearm function score at last follow-up.ResultsThe incisions healed by first intention. All 14 cases were followed up 12-36 months with an average of 24.8 months. All fractures healed, with an average healing time of 14.9 weeks (range, 12-18 weeks). The stabilities of the upper and lower radioulnar joints restored well. At last follow-up, the elbow flexion and extension range of motion was 65°-160°, with an average of 124.6°; the wrist flexion and extension range of motion was 115°-165°, with an average of 155.0°; the forearm rotation range of motion was 65°-165°, with an average of 154.6°. According to Anderson’s forearm function score, 8 cases were excellent, 5 cases were good, and 1 case was unsatisfactory. ConclusionThe treatment of bipolar fracture-dislocation of the forearm needs comprehensive consideration and individualized treatment plan. The focus is to restore the anatomical structure of the radius and ulna and firm internal fixation, stabilize the upper and lower radioulnar joints, and perform functional exercises as soon as possible after operation to obtain satisfactory effectiveness.