Objective To evaluate the early and middlelongterm clinical results of tricuspid valve replacement (TVR) and compare the relative merit between bioprothesis and mechanical valve in tricuspid position,so as to elevate the operative effect. Methods The data of 128 TVR from April 1992 to February 2008 in An Zhen Hospital were retrospectively reviewed, and classified into mechanical prosthesis group(n=89)and bioprothesis group(n=39)according to the prosthesis used in the first procedure. Kaplan-Meier curve were estimated to evaluate the midlong term survival rate and events incidence related to prosthesis(including thrombosis, embolism and bleeding related to prosthesis and the prosthesis deterioration). Multivariate binary logistic regressions were used to evaluate the independent risk factor for early and late death. Results There were 19 early deaths( 14.84%). With the followup of 4.93±2.92 years, there were 11 late deaths(10.7%). According to the Kaplan-Meier curve, the 10year actuarial survival rate for the bioprothesis group and mechanical prosthesis group were 65.6%±17.4% and 68.7%±10.8% respectively(Log-rank test,χ2=0.74,P=0.390). Freedom from prosthesis-related embolism at 5 years for the bioprothesis group and mechanical prosthesis group were 92.3%±7.4% and 87.1%±4.6% respectively(Log-rank test, χ2=0.962,P=0.327). Freedom from anticoagulationrelated bleeding at 10 years for the bioprothesis group and mechanical prosthesis group were 100% and 79.7%±9.7% respectively(Log-rank test, χ2=1.483,P= 0.223). There were 9 TVR reoperation, freedom from reoperation at 7 years for the bioprothesis group was 71.1%±18.0%, and freedom from reoperation at 10 years for the mechanical prosthesis group was 78.8%±10.2% (Log-rank test, χ2=2.76,P=0.096). Binary logistic regression revealed that the redo procedure and ascites were independent risk factors for early death, whereas ascites, heart function of New York Heart Association class Ⅲ/Ⅳ and multi valve replacement were independent risk factors for late death.Conclusion To lower the operative mortality and late mortality and morbidity, TVR should be adopted prior to the deterioration of right heart function, and bioprothesis valve has similar early and middlelong term clinical effect with mechanical valve in tricuspid position.
ObjectiveTo summarize and analyze the risk factors and management of artificial valve slippage in transcatheter aortic valve implantation (TAVI).MethodsWe retrospectively analyzed the clinical data of 131 patients undergoing TAVI surgery in our center from September 2017 to May 2019, including 62 patients through transapical approach and 69 patients through transfemoral artery approach.ResultsA total of 131 patients received TAVI surgery, among whom 4 patients had slipped during the operation, 2 patients via transfemoral artery approach, and another 2 patients via transapical. The average age was 77±9 years with one female (25%). Preoperative evaluation, higher position and poor coaxial were main risk factors for valve slip in TAVI.ConclusionValve slippage is also a serious complication in TAVI surgery. Reasonable and effective treatment can avoid thoracotomy.
ObjectiveTo explore the short-term follow-up clinical effect of transcatheter valve-in-valve implantation treatment for mitral bioprosthesis deterioration.MethodsThe single center data of elderly patients with mitral valve bioprosthetic dysfunction who received transapical J-Valve intervention between January 2019 and May 2020 were reviewed and summarized. After the informed consent was signed, single lumen endotracheal intubation was performed under general anesthesia in hybrid operating room. The left intercostal small incision was used to explore the apical area. Fluoroscopy and three-dimensional esophageal ultrasound were used to guide the puncture needle. Then the guide wire entered the left atrium through the mitral valve biological valve. The catheter was exchanged, and the rigid support wire was exchanged. The reverse loaded J-Valve system was guided and implanted into the biological mitral valve with beating heart. The appropriate implantation depth was adjusted, and stent valve was released under rapid pacing. Post balloon dilation of the valve was performed if necessary.ResultsFrom January 2019 to May 2020, transcatheter J-Valve implantation was completed in 20 patients with mitral valve dysfunction and high-risk evaluation of routine thoracotomy and cardiopulmonary bypass (the Society of Thoracic Surgeon score above 6). In terms of the type of the the mitral bioprosthesis, there were 6 cases of Hancock valves, 7 cases of Perimount valves, 6 cases of Epic valves, and 1 case of Baxiter valve. In terms of the size of the the mitral bioprosthesis, there were 2 cases of size 29 valves, 11 cases of size 27 valves, and 7 cases of size 25 valves. One valve fell into the left ventricle at early stage. One patient had mild valve displacement during operation, and a second valve was implanted at the same time. The success rate of valve-in-valve implantation was 95%. The length of stay in intensive care unit was less than 6 h in 5 cases, 6-24 h in 13 cases, 24-48 h in 1 case, and more than 48 h in 1 case. No patient’s postoperative mitral regurgitation was moderate or above. The mean mitral valve pressure gradient was (5.2±2.3) mm Hg (1 mm Hg=0.133 kPa). Patients recovered well after the valve-in-valve implantation treatment, with no death within postoperative one month. One patient died of infection and multiple organ failure during follow-up after one month. Other patients recovered smoothly without serious complications.ConclusionsThe clinical effect of J-Valve intervention in the treatment of mitral valve bioprosthetic dysfunction through apical approach is good. The implantation can be completed under beating heart, avoiding cardiopulmonary bypass and routine thoracotomy cardiac arrest, which is worthy of further observation and follow-up.
ObjectiveTo analyze the characteristics of platelet changes and their influencing factors during postoperative hospitalization in patients who underwent transcatheter aortic valve implantation (TAVI). MethodsThe patients who underwent TAVI at Beijing Anzhen Hospital Valve Surgery Center between March 2017 and October 2021 were retrospectively selected. The patients were divided into a self-limiting group and a non-self-limiting group according to the characteristics of postoperative platelet decline. In addition, the general preoperative data, preoperative and postoperative ultrasound data, intraoperative data, and the use of anticoagulant drugs during the postoperative stay in the hospital were compared between the two groups. ResultsA total of 249 patients were enrolled in this study. There were 175 (70.3%) patients in the self-limiting group, including 100 males and 75 females, and there were 74 (29.7%) patients in the non-self-limiting group, including 43 males and 31 females, with no statistical difference between the two groups (P=0.863). The mean age of patients was 73.11±8.88 years in the self-limiting group and 71.54±10.39 years in the non-self-limiting group (P=0.231). The decline of platelets in the self-limiting group generally occurred on the postoperative day 2 and reached the lowest count on the postoperative day 4, and returned to the baseline level on the postoperative day 5-7, while the platelets in the non-self-limiting group changed by simple rise, fall or irregular fluctuation. Patients in the self-limiting group had severer preoperative aortic stenosis (P<0.001) and used more extracorporeal circulation assistance during surgery (P<0.001). Postoperatively, patients in the self-limiting group were more likely to have periaortic valve leakage than those in the non-self-limiting group (P=0.013). ConclusionPlatelet changes in most patients after TAVI show a self-limiting decline, which may be related to the severity of patients’ preoperative aortic stenosis, intraoperative extracorporeal circulation device use, and postoperative perivalvular leakage.