west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "WANG Yan." 8 results
  • Effect of Adenosine on Propofol Consumption in Total Intravenous Anesthesia

    目的 探讨全凭静脉麻醉中腺苷对丙泊酚用量的影响。 方法 2011年1月-12月期间59例行择期手术的患者全凭静脉麻醉,随机分为腺苷静脉持续输注组(A组)和对照组(B组),A组患者麻醉诱导后持续输注腺苷70 μg/(kg·min),直至术毕。B组麻醉后按常规处理。比较两组患者麻醉时间、苏醒时间、瑞芬太尼用量,麻醉过程中平均动脉压(MAP)、心率,以及麻醉过程中丙泊酚的用量。同时记录使用腺苷过程中的不良反应。 结果 两组患者麻醉时间、苏醒时间、瑞芬太尼用量比较均无明显差异,无统计学意义(P>0.05)。两组患者麻醉过程中MAP、心率比较亦无明显差异,无统计学意义(P>0.05)。两组患者麻醉过程中丙泊酚平均用量比较,A组明显低于C组,差异有统计学意义(P<0.05),且不良反应发生率低。 结论 腺苷能明显降低全凭静脉麻醉中丙泊酚的使用剂量。

    Release date:2021-06-23 07:35 Export PDF Favorites Scan
  • RESEARCH PROGRESS OF A DISINTEGRIN AND METALLOPROTEINASE WITH THROMBOSPONDIN MOTIF 4 AND 5 IN OSTEOARTHRITIS

    Objective To review the progress of a disintegrin and metalloproteinase with thrombospondin motif 4 (ADAMTS-4) and ADAMTS-5 in osteoarthritis. Methods Recent literature about the ADAMTS-4 and -5 in osteoarthritis was analyzed; the structure, function, inhibitors of the ADAMTS-4 and -5, and the relationship between the proteases and osteoarthritis were analyzed and summarized. Results ADAMTS-4 and -5 can reduce chondrocyte and extracellular matrix by degrading aggrecan and cartilage oligomeric matrix protein, which induced the pathogenesis of osteoarthritis. Conclusion ADAMTS-4 and -5 have been demonstrated to play important roles in osteoarthritis. It can better guide treatment and prevention of osteoarthritis to further study related mechanism of ADAMTS-4 and -5, and to promote the establishment of a clinical drug targets.

    Release date:2016-08-31 04:12 Export PDF Favorites Scan
  • PROGRESS OF IN VIVO STUDY ON DEGRADABLE MAGNESIUM ALLOYS APPLICATION AS BONE-IMPLANT MATERIALS

    Objective To review the progress of in vivo study on degradable magnesium alloys application as bone-implant materials. Methods Recent literature was extensively reviewed and summarized, concerning the in vivo study on degradable magnesium alloys as orthopaedic implants. Results Magnesium alloys possess a natural ability to degrade via corrosion in vivo, which is promising candidate material for orthopaedic medical device applications. A great progress has been made to improve in vivo performance and integration with bone tissue. However, the degradation mechanism of magnesium-based materials in the physiological environment and long-term effect on body are not available. The modulation of the corrosion rate of magnesium alloys must also be accomplished. Conclusion Magnesium alloys have the potential to serve as degradable implants for orthopaedic applications, but a great deal of further investigation is still necessary.

    Release date:2016-08-31 04:22 Export PDF Favorites Scan
  • PEDICLE SUBTRACTION OSTEOTOMY FOR CORRECTION OF KYPHOSIS IN ANKYLOSING SPONDYLITIS

    Objective To assess the effectiveness of single-level lumbar pedicle subtraction osteotomy for correction of kyphosis caused by ankylosing spondylitis. Methods Between July 2006 and July 2010, 45 consecutive patients with kyphosis caused by ankylosing spondylitis underwent single-level pedical subtraction osteotomy. There were 39 males and 6 females with an average age of 36.9 years (range, 21-59 years). The average disease duration was 18.6 years (range, 6-40 years). All patients had low back pain, fatigue, abnormal gaits, and disability of looking and lying horizontally. Radiological manifestations included sacroiliac joints fusion, bamboo spine, pelvic spin, and kyphosis. Cervical spine was involved in 30 patients; thoracolumbar spine was affected in 15 patients. Results Wound hydrops and dehiscence occurred in 1 case, and was cured after debridement; primary healing of incision was obtained in the other patients. Two patients had abdominal skin blisters, which were cured after magnesium sulfate wet packing. Forty-two patients were followed up 24-74 months (mean, 30 months). All osteotomy got solid fusion. The average bony fusion time was 6.8 months (range, 3-12 months). All patients could walk with brace and looked or lied horizontally postoperatively. The Scoliosis Research Society-22 Patient Questionnaire (SRS-22) score, T1-S1 kyphosis Cobb angle, L1-S1 lordosic Cobb angle, sagittal imbalance distance, and chin-brow vertical angle at 1 week and last follow-up were significantly improved when compared with those at preoperation (P lt; 0.05), but no significant difference was found between at 1 week and last follow-up (P gt; 0.05). Conclusion Single-level pedicle subtraction osteotomy has satisfactory effectiveness for the correction of kyphosis caused by ankylosing spondylitis.

    Release date:2016-08-31 04:07 Export PDF Favorites Scan
  • RESTORATION OF THORACIC KYPHOSIS WITH MULTILEVEL Ponte OSTEOTOMIES IN THORACIC IDIOPATHIC SCOLIOSIS SURGERY

    Objective To investigate the effectiveness of multilevel Ponte osteotomies on maintenance and restoration of thoracic kyphosis in idiopathic scoliosis (IS) surgery. Methods Between March 2008 and February 2010, 42 patients with thoracic IS (Lenke type 1 curves) were corrected with posterior pedicle screw system. Multilevel Ponte osteostomies for posterior release was performed in 17 cases (group A), and the 3 segments near the apical vertebrae were selected as the osteotomy site; simple posterior soft tissue release was given in 25 cases (group B). There was no significant difference in sex, age, disease duration, lesion segments, coronary Cobb angle, thoracic kyphosis, Risser index, and bending flexibility between 2 groups (P gt; 0.05). The anteroposterior and lateral standing radiographs of the spine were taken to compare the effectiveness between 2 groups. Results Operation was successfully completed in all patients. The operation time and blood loss in group A were significantly greater than those in group B (P lt; 0.05). Spine dural injury and leakage of cerebrospinal fluid occurred in 1 case of group A, which was cured after compression on local area of the wound; the other patients had no intraoperative complications. The patients were followed up 2-4 years (mean, 2.8 years); no nerve injury, infection, or internal fixation failure occurred. No obvious correction loss was observed and the appearance and trunk balance were significantly improved. The coronal Cobb angles at 1 week and 2 years after operation were significantly improved when compared with preoperative ones in 2 groups (P lt; 0.05). There was no significant difference in the coronal Cobb angle and correction rate between 2 groups at 1 week and 2 years after operation (P gt; 0.05). Group A was significantly better than group B in the thoracic kyphotic angle and angle changes at 1 week and 2 years after operation (P lt; 0.05). Conclusion The posterior approach surgery with multilevel Ponte osteotomies can restore the thoracic kyphosis in IS, but it has no effect on coronal correction in Lenke type 1 curves.

    Release date:2016-08-31 04:21 Export PDF Favorites Scan
  • HEALING EFFICACY OF REPAIRING MUCOSA DEFECT WITH HETEROGENEITY ACELLULAR DERMAL MATRIX

    【Abstract】 Objective To introduce the cl inical appl ication of heterogeneity (cattle) acellular dermal matrix(ADM)in the repair of mucosa defect otolaryngology. Methods From October 2006 to March 2007, 12 cases of mucosa defect was repaired with heterogeneity ADM after the surgery. There were 10 males and 2 females, aged 18-76 years. Defect was caused by deflection of nasal septum in 1 case, melanoma of front and midst basal is (capillary hemangioma) in 1 case, nasal vestibule angioma (T2N2M0)in 1 case, cancer of hypopharynx (T2N1M0) in 1 case, cancer of amygdale in 3 cases (2 of T2N0M0 and 1 of T3N1M0),cervical segments esophageal carcinoma in 1 case, and cancer of larynx in 4 cases (3 of T2N0M0 and 1 of T3N1M0). Results All these 12 cases were followed up for 6 months. The results of endoscope showed that heterogeneity ADM mingled with mucosa within 3 months after operation and the function was recovered. Pharynx fistula occurred in 1 case of hypopharynx cancer afterthe operation. After treatment of dressing change and antibiotics for 10 days, the wound healed, but after 2 months tumor recurred. All the patients were treated by radiation treatment. One case of amygdala cancer recurred and transferred to the neck after 2 months of radiation treatment. But 1 case of hypopharynx cancer died of massive haemorrhage after radiation treatment for 3 months. Conclusion Heterogeneity ADM can be easily obtained and it is a new method to repair mucosa defect. Theoperative procedure is easy to perform and worthwhile to be appl ied to cl inical operation.

    Release date:2016-09-01 09:09 Export PDF Favorites Scan
  • TOTAL HIP ARTHROPLASTY WITH DOUBLE-TAPERED CEMENTLESS FEMORAL STEM FOR HIP BONY FUSION

    Objective To investigate the effectiveness of total hip arthroplasty with double-tapered cementless femoral stem for hip bony fusion by comparing with anatomical cementless femoral stem. Methods A retrospective analysis was made on clinical data of 50 cases (80 hips) of hip bony fusion undergoing total hip arthroplasty between October 1999 and January 2008. The patients were divided into 2 groups: 31 cases (49 hips) using BetaCone double-tapered cementless femoral stem (trial group), and 19 cases (31 hips) using Ribbed anatomical cementless femoral stem (control group). There was no significant difference in gender, age, disease duration, preoperative Harris score, and abduction angle of the hip between 2 groups (P gt; 0.05). After operation, X-ray films were used to calculate the ratio of force arm of abductor (a) to the force arm of gravity (b) and analyze the stability of the prosthesis. The abduction angle of the hip and Harris score were measured during follow-up. Results Fracture occurred during operation in 9 hips of 9 cases (5 in trial group and 4 in control group), and was cured after fixation. The mean follow-up time was 49 months (range, 12-98 months) in trial group and was 53 months (range, 6-105 months) in control group. The ratio of a/b was 0.65 ± 0.25 in trial group and was 0.56 ± 0.37 in control group, showing significant difference (t=2.19, P=0.03). The abduction angle of hip was (34.49 ± 7.58)° in trial group and was (30.97 ± 7.24)° in control group at 6 months after operation, which was significantly improved when compared with preoperative value in 2 groups (P lt; 0.05), and significant difference was found between 2 groups (t=2.06, P=0.04). Postoperative Harris score was significantly improved in 2 groups when compared with preoperative score (P lt; 0.05); trial group was better than control group in Harris score at 1 month after operation (t=3.62, P=0.01), but no significant difference was found between 2 groups at last follow-up (t=1.61, P=0.11). At last follow-up, X-ray films showed stabilized prosthesis in 2 groups. Grade I or II ectopic ossification occurred in 12 cases (14 hips) of trial group and 8 cases (9 hips) of control group at 2 years after operation. Conclusion The total hip arthroplasty with both double-tapered and anatomical cementless femoral stems for hip bony fusion can obtain satisfactory effectiveness, while the double-tapered cementless femoral stem has better abduction angle of hip.

    Release date:2016-08-31 04:07 Export PDF Favorites Scan
  • APPLICATION OF INTRAOPERATIVE CT NAVIGATION IN POSTERIOR THORACIC PEDICLE SCREW PLACEMENT FOR SCOLIOSIS PATIENTS

    Objective To investigate the application value of intraoperative CT navigation in posterior thoracic pedicle screw placement for scoliosis patients. Methods Between October 2009 and December 2011, 46 patients with scoliosis were treated with thoracic pedicle screw placement under intraoperative CT navigation in 21 cases (group A) or under C-arm fluoroscopy in 25 cases (group B). There was no significant difference in age, gender, type of scoliosis, involved segment, and Cobb angle of main thoracic curve between 2 groups (P gt; 0.05). A total of 273 thoracic pedicle screws were placed in group A and 308 screws in group B. The pedicle screw position evaluated and classified by intraoperative CT images according to the Modi et al. method; and the accurate rate, the safe rate, and the potential risk rate of pedicle screws were calculated on the upper thoracic spine (T1-4), the middle thoracic spine (T5-8), the lower thoracic spine (T9-12), and the entire thoracic spine (T1-12). The accuracy and security of thoracic pedicle screw placement were compared between 2 groups. Results On the entire thoracic spine, the accurate rate of group A (93.4%) was significantly higher than that of group B (83.8%), the safe rate of group A (98.9%) was significantly higher than that of group B (92.5%), showing significant differences between 2 groups (P lt; 0.05). However, the potential risk rate of group B (7.5%) was significantly higher than that of group A (1.1%) (P lt; 0.05). On the upper, the middle, and the lower thoracic spines, there was no significant difference in the accurate rate, the safe rate, and the potential risk rate of pedicle screws between 2 groups (P gt; 0.05). According to CT evaluation results, the potential risk pedicle screws were revised or removed during operation. The patients of 2 groups had no neurological deficits through physical examination of nervous system at 3 days after operation. Conclusion Intraoperative CT navigation can improve the accuracy and security of posterior thoracic pedicle screw placement and it can ensure the safety of operation by finding and promptly removing or revising the potential risk pedicle screws.

    Release date:2016-08-31 04:22 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content