west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "WEI Peijian" 13 results
  • Research progress of transcatheter aortic valve replacement in patients with coexisting moderate to severe mitral regurgitation

    After nearly two decades of application and development, the clinical efficacy of transcatheter aortic valve replacement (TAVR) has been continuously improved and demonstrated. Due to the expansion of indications of TAVR, the frequency of encountering patients with mixed valvular diseases increases greatly, particularly the moderate to severe mitral regurgitation combined with aortic stenosis. Multiple registry studies suggest that the incidence of significant mitral regurgitation is approximately 13% to 74% in patients who undergo TAVR. Some studies have reported that moderate to severe MR is associated with higher mortality, while simultaneous aortic and mitral valve surgery is associated with significantly higher surgical risk. Therefore, the optimal treatment strategy for this special patient group remains uncertain. With the further development of transcatheter therapy, staged surgery may be a feasible solution. However, there is currently a lack of evidence-based support such as randomized clinical trials. This review aims to report and evaluate relevant existing research data to help clinicians make optimal treatment decisions for this specific patient populations.

    Release date: Export PDF Favorites Scan
  • Two-staged hybrid ablation versus thoracoscopic epicardial ablation for long-standing persistent atrial fibrillation: Mid-long term result of a randomized controlled trial

    ObjectiveTo evaluate the efficacy of hybrid ablation through compared with thoracoscopic epicardial ablation.MethodsIn this study, 108 patients with all long-standing persistent atrial fibrillation (LSPAF) received thoracoscopic epicardial ablation (TEA) after enrollment. There were 82 males and 26 females at age of 56.5±9.4 years. After blanking-period, patients off antiarrhythmic therapy with sinus rhythm were divided into a hybrid ablation (HA) group (50 patients) and a TEA group (58 patients). Only patients in the HA group received catheter ablation after randomization subsequently. In at least two-year observation period, cardiovascular risk factors were observed in all groups’ patients.ResultsThe mean follow-up duration was 17.3-41.8 (26.9±6.1) months and there was no significant difference between two groups [8.2-40.6 (27.5±5.7) months in the HA group and 17.3-41.8 (26.4±6.7) months in the TEA group]. The off antiarrhythmic agents (AADs) sinus rhythm rate was significantly higher in the HA group than that in the TEA group at the time of postoperative 6, 12, 24 and 36 months [96.0%, 90.0%, 83.7%, 83.7% versus 79.3%, 75.9%, 67.3%, 63.1%, HR=0.415 (95%CI 0.206-0.923)].ConclusionWe can conclude that the efficacy of two-staged hybrid ablation for LSPAF is superior to thoracoscopic epicardial ablation alone. Patients can obtain benefit from a supplemental radiofrequency catheter ablation after blanking-period of surgical ablation, instead of those without a supplemental ablation.

    Release date:2021-03-05 06:30 Export PDF Favorites Scan
  • Establishment of patent ductus arteriosus model in Bama miniature pigs using autogenous jugular vein

    ObjectiveTo explore the method and feasibility of establishing patent ductus arteriosus (PDA) model in Bama miniature pig by using autologous jugular vein, and to provide a large animal model for the development of PDA occluder and the study of pulmonary hypertension associated with congenital heart disease. MethodsFive Bama miniature pig weighing about 45 kg were selected to gain the PDA model of the autogenous jugular vein, which was fixed by glutaraldehyde and anastomosed between the ascending aorta and the main pulmonary artery. The patency of PDA was confirmed by echocardiography and angiocardiography immediately and one week after the operation. Two animals were selected to undergo transcatheter closure of PDA via femoral vein 1 week after operation, and the rest were euthanized to obtain PDA and lung tissue for pathological examination. ResultsThe PDA model was successfully established in all five animals with a success rate of 100%. Immediately and 1 week after operation, echocardiography and angiography showed that PDA blood flow was unobstructed, and hematoxylin-eosin staining showed that PDA endothelialization was good. One week after operation, two animals were successfully treated with transcatheter femoral vein occlusion. The pathological examination of lung tissue showed thickening of the intima and muscular layer of pulmonary arterioles, thickening of pulmonary interstitium and infiltration of neutrophils. ConclusionIt is safe and feasible to establish a large animal model of PDA by using autogenous jugular vein anastomosis between the ascending aorta and the main pulmonary artery. The model can be used for the development of PDA interventional occlusive devices and the pathophysiological study of congenital heart disease-related pulmonary hypertension.

    Release date: Export PDF Favorites Scan
  • Totally endoscopic transmitral septal myectomy for the treatment of recurrent left ventricular outflow tract obstruction after alcohol septal ablation

    ObjectiveTo investigate the surgical strategies and clinical efficacy of transmitral septal myectomy in the treatment of recurrent left ventricular outflow tract obstruction (LVOTO) after alcohol septal ablation. MethodsThe clinical data of patients with recurrent LVOTO after alcohol septal ablation from July 2020 to July 2021 in the Department of Cardiac Surgery, Guangdong Provincial People's Hospital were retrospectively analyzed. Patients were preoperatively evaluated by echocardiography, cardiac magnetic resonance imaging, cardiac computed tomography, 3D modeling and printing technology. A personalized surgical strategy was preoperatively developed according to multimodality imaging assessment, while visual exploration was performed on the digital model and simulated surgical resection was performed on the printed model. Results Two female patients were enrolled, aged 62 years and 64 years, respectively. Totally endoscopic transmitral extended myectomy was successfully performed on both patients with aortic cross-clamping time of 96 min and 85 min, respectively. LVOTO was relieved immediately (subaortic peak pressure gradient decreased from 100 mm Hg to 4 mm Hg and from 84 mm Hg to 6 mm Hg, respectively) and the mitral regurgitation significantly improved after the procedure. No patient had complete atrioventricular block or required permanent pacemaker implantation. The patients were discharged uneventfully without postoperative complications. ConclusionPersonalized totally endoscopic transmitral extended myectomy combined with multimodality imaging assessment and 3D modeling and printing has an acceptable clinical effect in patients with recurrent LVOTO after alcohol septal ablation. The procedure can precisely resect the hypertrophic septal myocardium while avoiding serious complications such as septal perforation or complete atrioventricular block.

    Release date:2023-07-25 03:57 Export PDF Favorites Scan
  • Transapical approach under 3D printing guidance for myectomy in apical hypertrophic cardiomyopathy: A case report

    We reported a 26-year-old male who was diagnosed with apical hypertrophic cardiomyopathy with left ventricular aneurysm. The location of the hypertrophic myocardium and the extent of resection were accurately assessed preoperatively using 3D modeling and printing technology. Myectomy was performed via transapical approach, and the intraoperative exploration was consistent with the description of the preoperative 3D modeling. The patient underwent the surgery successfully without any complications during the hospitalization, and the cardiopulmonary bypass time was 117 min, the aortic cross-clamping time was 57 min, and the hospital stay time was 7 d. The postoperative echocardiography demonstrated left ventricular cavity flow patency. This case provides a reference for the management of patients with apical hypertrophic cardiomyopathy.

    Release date: Export PDF Favorites Scan
  • Echo-guiding percutaneous aortic stent implantation for coarctation of the aortic: A case report

    Currently, transcatheter intervention has emerged as a first-line treatment for coarctation of the aortic. Due to the radiation exposure associated with catheter interventional therapy, there are numerous restrictions, which harms both patients and medical personnel and is dependent on sizable radiation apparatus. Here, we report for the first time a case of echo-guiding percutaneous aortic stent implantation for a 27 years female patient of reproductive age. After discharge, the patient's aortic coarctation pressure decreased to 18 mm Hg, and the surgical results were satisfactory.

    Release date: Export PDF Favorites Scan
  • Clinical efficacy of percutaneous balloon mitral valvuloplasty under echocardiographic guidance for moderate to severe mitral stenosis during pregnancy

    Objective To investigate the effect of percutaneous balloon mitral valvuloplasty under echocardiographic guidance for patients with moderate to severe mitral stenosis during pregnancy. Methods A retrospective observational study was conducted to include pregnant women who were diagnosed with moderate to severe mitral stenosis and underwent percutaneous balloon mitral valvuloplasty under echocardiographic guidance in Fuwai Hospital from August 2018 to June 2022, and their baseline characteristics, surgical outcomes, echocardiographic results, and follow-up results were analyzed. Results A total of 3 pregnant women aged 30-35 years, with gestational age of 19-26 weeks, and New York Heart Association (NYHA) function class Ⅲ were included. All the procedures were successfully performed. The mitral valve orifice area increased from 0.9 cm2 preoperatively to 2.1 cm2 postoperatively. The mean transvalvular pressure gradient decreased from 15.0 mm Hg preoperatively to 6.7 mm Hg postoperatively. No perioperative adverse events occurred. The follow-up time ranged from 3 to 48 months. All patients delivered uneventfully and returned to normal life, with maternal-fetal safety. Conclusion Percutaneous balloon mitral valvuloplasty under echocardiographic guidance is a feasible and effective procedure for the treatment of patients with moderate to severe mitral stenosis in pregnancy, with satisfactory maternal-fetal outcomes.

    Release date:2024-08-22 04:25 Export PDF Favorites Scan
  • Transapical transcatheter valve-in-valve implantation treatment for patients with deteriorated mitral bioprosthesis after aortic-mitral double valve replacement

    ObjectiveTo determine the clinical efficacy of transapical transcatheter mitral valve-in-valve treatment for patients with deteriorated mitral bioprosthesis after aortic-mitral double valve replacement.MethodsThe clinical data of 9 patients who underwent transapical transcatheter mitral valve-in-valve implantation after aortic-mitral double valve replacement due to mitral bioprosthesis deterioration from May 2020 to January 2021 in our hospital were retrospectively analyzed, including 4 males and 5 females with a mean age of 72.44±7.57 years.ResultsSurgeries were performed successfully in all patients with no conversion to median sternotomy. The mean procedural time was 101.33±48.49 min, the mechanical ventilation time was 23.11±26.54 h, the ICU stay was 1.89±1.05 d and the postoperative hospital stay was 6.11±2.02 d. Residual mild mitral regurgitation was only observed in 1 patient. Only 1 patient needed postoperative blood transfusion. No major complications were observed in all patients. There was no death in postoperative 90 days.ConclusionFor patients with deteriorated mitral bioprosthesis after aortic-mitral double valve replacement, transapical transcatheter mitral valve-in-valve implantation achieves good clinical results and effectively improves the hemodynamics without increasing the risk of postoperative left ventricular outflow tract obstruction. The surgery is feasible and effective.

    Release date:2021-07-28 10:22 Export PDF Favorites Scan
  • Totally endoscopic transmitral myectomy and traditional thoracotomy for hypertrophic obstructive cardiomyopathy: A propensity score matching analysis

    ObjectiveTo investigate the effectiveness and safety of totally endoscopic transmitral myectomy (TETM) for hypertrophic obstructive cardiomyopathy (HOCM), comparing with traditional sternotomy modified Morrow procedure (SMMP).MethodsThirty-eight patients with HOCM who needed surgical intervention were selected from our hospital in 2019, including 14 males and 24 females, with an average age of 56 (44-68) years. According to the operation method, they were divided into a TETM group (n=18) and a SMMP group (n=20). Appropriate patients were screened by propensity matching scores. Finally, the clinical data of two matched groups were compared and analyzed.ResultsThere was no death, septal perforation, residual left ventricular outflow tract obstruction or third degree atrioventricular block in either group. After propensity score matching, there was no statistical difference between the two groups in the ICU length of stay (41.5±5.0 h vs. 53.0±24.0 h, P=0.620), ventilation time (19.5±9.2 h vs. 38.0±24.0 h, P=0.463), cardiopulmonary bypass time (190.7±45.6 min vs. 156.0±70.7 min, P=0.627), aortic cross-clamp time (100.1±25.3 min vs. 94.5±57.3 min, P =0.915), left ventricular outflow tract gradient (17.0±1.4 mm Hg vs. 5.0±0.5 mm Hg, P=0.053), left atrial anterior and posterior diameter (37.0±1.3 mm vs. 40.0±0.7 mm, P=0.090), interventricular septum thickness (12.5±0.7 mm vs. 13.0±1.4 mm, P=0.712), left ventricular posterior wall thickness (10.0±1.4 mm vs. 10.5±2.1 mm, P=0.811), left ventricular end-diastolic diameter (43.5±3.5 mm vs. 46.0±4.2 mm, P=0.589), and mitral regurgitation (1.0±0.2 vs. 0.7±0.5, P=0.500). The follow-up time was 6±3 months, and no death occurred. In the TETM group, one patient underwent mitral valvuloplasty again three months after surgery because of a tear in the A3 region of mitral valve..ConclusionTETM is a safe and effective procedure that can well expose the interventricular septum at the basal & middle obstruction site and effectively eliminate the mitral regurgitation associated with systolic anterior motion syndrome caused by left ventricular outflow tract obstruction.

    Release date:2021-07-02 05:22 Export PDF Favorites Scan
  • Transapical transcatheter aortic valve replacement for aortic regurgitation in a patient with extremely horizontal aorta

    An 81-year-old male patient was admitted to Guangdong Provincial People's Hospital due to chest distress and shortness of breath after activity for half a year. Examination after admission revealed severe aortic insufficiency, tricuspid aortic valve and extremely horizontal aorta with an aortic root angulation of 99°. The Society of Thoracic Surgeons score was 7%. And taking the strong demand of the patient and his family into consideration, we decided to perform transapical transcatheter aortic valve replacement after multidisciplinary evaluation. The procedure was successfully performed by means of low deployment land zone and traction of pre-exist Prolene suture. Three-month follow-up confirmed the normal function of aortic prosthetic valve without residual regurgitation. This case provides a reference for the interventional treatment in patients with extremely horizontal aorta.

    Release date: Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content