ObjectiveTo evaluate the efficacy and safety of a novel wire for echo-guiding percutaneous atrial septal defect (ASD) closure.MethodsTwenty sheep were randomly divided into two groups, an experimental group and a control group (n=10 in each group). In both groups, an animal model of ASD was established by transthoracic balloon dilatation, and percutaneous closure of atrial septal defect was finished only by echography guiding. The total procedure time, passing time (time needed for the guide wire to enter the left atrium), frequency of delivery sheath dropping into right atrium, frequency of arrhythmias and rate of complications were compared between the two groups.ResultsASD model was uneventfully established in all animals. ASD devices were successfully implanted in all sheep. Compared with the control group, the experimental group had significantly less mean procedure time and mean passing time, lower frequency of guide wire dropping into right atrium and frequency of atrial and ventricular premature contractions, respectively (15.36±4.86 min vs. 25.82±7.85 min, 2.69±0.82 min vs. 5.58±3.34 min, 0% vs. 40.0%, 4.41±2.61 vs. 9.60±3.68, 0.75±0.36 vs. 1.34±0.68; all P<0.05) . Two groups did not have serious complications within postoperative one week.ConclusionThe novel wire system is not only safe and effective in the treatment of ASD occlusion, but also easy to operate.
ObjectiveTo compare clinical efficacy of single-incision laparoscopic surgery (SILS) and conventional laparoscopic surgery (CLS) in treatment of colorectal cancer.MethodsThe Pubmed, Embase, Cochrane library, CBM, CNKI, VIP, and Wanfang Data were searched to collect the comparative study of the SILS and CLS in the treatment of colorectal cancer. The data were extracted and evaluated by the RevMan 5.3 software.ResultsEventually, 13 articles were included, including 3 randomized controlled trials and 10 case-control studies with a total of 1 466 patients. The meta-analysis results suggested that the SILS could shorten the postoperative hospital stay [MD=–0.63, 95% CI (–1.10, –0.16), P=0.009] and time to the first flatus [MD=–0.23, 95% CI (–0.33, –0.13), P<0.000 01] and the lymph node dissection was relatively completed [MD=0.77, 95% CI (0.05, 1.48), P=0.04] as compared with the CLS. In the total complications of surgery [OR=0.73, 95% CI (0.51, 1.03), P=0.08], operation time [MD=–0.33, 95% CI (–11.36, 10.69), P=0.95], intraoperative blood loss [MD=5.61, 95% CI (–4.20, 15.43), P=0.26], conversion to laparotomy [OR=1.06, 95% CI (0.18, 6.13), P=0.95], distance between tumor and proximal margin [MD=0.11, 95% CI (–0.48, 0.69), P=0.71], distance between tumor and distal margin [MD=0.32, 95% CI (–0.23, 0.87), P=0.25] had no statistically significant differences between the SILS and CLS.ConclusionsSILS is safe and effective for radical resection of colorectal cancer. However, results of study still need to be validated by a randomized controlled trial with a large sample designed strictly.
ObjectiveTo assess the feasibility and safety of percutaneous transcatheter closure of atrial septal defect (ASD) guided by transthoracic echocardiography (TTE) in outpatients.MethodsFrom December 2016 to June 2018, 50 simple ASD patients underwent TTE-guided transcatheter closure in the outpatient operating room of our hospital (a TTE group) including 22 males and 28 females at the age of 16-48 (27.40±6.95) years. Fifty patients with simple ASD treated with the guidance of conventional fluoroscopy during the same period were treated as a control group, including 22 males and 28 females at the age of 15-48 (28.58±6.96) years. Both groups were re-examined by TTE during follow-up at 1 month, 3 months, 6 months and 1 year.ResultsThe mean age, body weight, the size of ASD and occluder and success rate had no statistical difference between the two groups (P>0.05). Compared with the control group, the TTE group had significantly lower mean operation time (P<0.01) and less cost (P<0.01) since patients need not to be hospitalized. No related complications were found in the TTE group during follow-up.ConclusionPercutaneous transcatheter closure of ASD guided by TTE appears safe and effective for outpatients, and can significantly reduce the cost.
Objective To assess the efficacy and safety of percutaneous closure of patent ductus arteriosus (PDA) solely under echocardiography guidance. Methods We retrospectively analyzed the clinical data of 200 patients who received the percutaneous closure of PDA under echocardiography guidance in Fuwai Hospital from August 2013 to April 2016. According the different approach, they were divided into 2 groups: a femoral artery approach group (n=143) and a femoral vein approach group (n=57). In the femoral artery approach group, there were 42 males and 101 females aged 3.20±5.63 years. In the femoral vein group, there were 10 males and 47 females aged 7.30±11.36 years. All Patients were treated by percutaneous PDA closure solely under echocardiography guidance. The follow-up was performed at one month after the operation by echocardiography, chest radiograph and electrocardiogram. Results All 200 patients were successfully treated with percutaneous closure of PDA. The patients’ gender, in-hospital stay, rates of occluder detachment were similar between the two groups (P>0.05). Compared with the femoral vein approach group, the femoral artery approach group had a younger age (3.20±5.63 yearsvs. 7.30±11.36 years, P<0.001), less body weight (14.25±11.54 kgvs. 24.25±19.14 kg, P<0.001) and shorter diameter of PDA (3.06±0.79 mmvs. 5.93±0.68 mm, P<0.001) and PDA occluders (5.43±1.00 mmvs. 12.14±0.54 mm, P<0.001), but had higher hospitalization expenses (32 108.2±3 100.2 yuanvs.25 120.7±3 534.1 yuan, P<0.001). In the femoral vein approach group, one patient was closed under radiation guidance because guide wires could not pass through PDA. One patient in the femoral artery approach group suffered from occluder detachment at one day after operation and was cured by transthoracic minimally invasive PDA occlusion. There were no complications of occluder detachment, residual shunt, pericardial effusion or left pulmonary stenosis during the follow-up. Conclusion Echocardiography-guided percutaneous PDA closure is safe and effective, while the proper interventional approach should be chosen by the anatomical features of PDA.